Mohd Alauddin Mohd Ali

Mohd Alauddin Mohd Ali

Auto-generated profile, based on publicly available information

Mohd Alauddin Mohd Ali

Department of Electrical, Electronic & Systems Engineering, Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia (UKM), Bangi, Selangor 43600, Malaysia

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 September 2013 in Sensors
Verified
Journal Article
Open access
PDF file
RCRubana Chowdhury
Rubana Chowdhury
Mamun Bin Ibne ReazMamun Bin Ibne Reaz
Mamun Bin Ibne Reaz
MAMohd Alauddin Bin Mohd Ali
Mohd Alauddin Bin Mohd Ali
ABAhmad Ashrif A Bakar
Ahmad Ashrif A Bakar
KCKalaivani Chellappan
Kalaivani Chellappan
TCTae Gyu Chang
Tae Gyu Chang
Electromyography (EMG) signals are becoming increasingly important in many applications, including clinical/biomedical, prosthesis or rehabilitation devices, human machine interactions, and more. However, noisy EMG signals are the major hurdles to be overcome in order to achieve improved performance in the above applications. Detection, processing and classification analysis in electromyography (EMG) is very desirable because it allows a more standardized and precise evaluation of the neurophysiological, rehabitational and assistive technological findings. This paper reviews two prominent areas; first: the pre-processing method for eliminating possible artifacts via appropriate preparation at the time of recording EMG signals, and second: a brief explanation of the different methods for processing and classifying EMG signals. This study then compares the numerous methods of analyzing EMG signals, in terms of their performance. The crux of this paper is to review the most recent developments and research studies related to the issues mentioned above.

17 May 2013 in Sensors
Verified
Journal Article
Open access
PDF file
MAMahmoud Al-Kadi
Mahmoud Al-Kadi
Mamun Bin Ibne ReazMamun Bin Ibne Reaz
Mamun Bin Ibne Reaz
MAMohd Alauddin Mohd Ali
Mohd Alauddin Mohd Ali
Biosignal analysis is one of the most important topics that researchers have tried to develop during the last century to understand numerous human diseases. Electroencephalograms (EEGs) are one of the techniques which provides an electrical representation of biosignals that reflect changes in the activity of the human brain. Monitoring the levels of anesthesia is a very important subject, which has been proposed to avoid both patient awareness caused by inadequate dosage of anesthetic drugs and excessive use of anesthesia during surgery. This article reviews the bases of these techniques and their development within the last decades and provides a synopsis of the relevant methodologies and algorithms that are used to analyze EEG signals. In addition, it aims to present some of the physiological background of the EEG signal, developments in EEG signal processing, and the effective methods used to remove various types of noise. This review will hopefully increase efforts to develop methods that use EEG signals for determining and classifying the depth of anesthesia with a high data rate to produce a flexible and reliable detection device.

29 August 2013 in SpringerPlus
Verified
Journal Article
Open access
PDF file
DADhifaf Azeez
Dhifaf Azeez
MAMohd Alauddin Mohd Ali
Mohd Alauddin Mohd Ali
Kok Beng GanKok Beng Gan
Kok Beng Gan
ISIsmail Saiboon
Ismail Saiboon
Unexpected disease outbreaks and disasters are becoming primary issues facing our world. The first points of contact either at the disaster scenes or emergency department exposed the frontline workers and medical physicians to the risk of infections. Therefore, there is a persuasive demand for the integration and exploitation of heterogeneous biomedical information to improve clinical practice, medical research and point of care. In this paper, a primary triage model was designed using two different methods: an adaptive neuro-fuzzy inference system (ANFIS) and artificial neural network (ANN).When the patient is presented at the triage counter, the system will capture their vital signs and chief complains beside physiology stat and general appearance of the patient. This data will be managed and analyzed in the data server and the patient’s emergency status will be reported immediately. The proposed method will help to reduce the queue time at the triage counter and the emergency physician’s burden especially duringdisease outbreak and serious disaster. The models have been built with 2223 data set extracted from the Emergency Department of the Universiti Kebangsaan Malaysia Medical Centre to predict the primary triage category. Multilayer feed forward with one hidden layer having 12 neurons has been used for the ANN architecture. Fuzzy subtractive clustering has been used to find the fuzzy rules for the ANFIS model. The results showed that the RMSE, %RME and the accuracy which evaluated by measuring specificity and sensitivity for binary classificationof the training data were 0.14, 5.7 and 99 respectively for the ANN model and 0.85, 32.00 and 96.00 respectively for the ANFIS model. As for unseen data the root mean square error, percentage the root mean square error and the accuracy for ANN is 0.18, 7.16 and 96.7 respectively, 1.30, 49.84 and 94 respectively for ANFIS model. The ANN model was performed better for both training and unseen data than ANFIS model in term of generalization. It was therefore chosen as the technique to develop the primary triage prediction model. This primary triage model will be combined with the secondary triage prediction model to produce the final triage category as a tool to assist the medical officer in the emergency department.

21 July 2014 in Sensors
Verified
Journal Article
Open access
PDF file
MAMahmoud Al-Kadi
Mahmoud Al-Kadi
Mamun Bin Ibne ReazMamun Bin Ibne Reaz
Mamun Bin Ibne Reaz
MAMohd Alauddin Mohd Ali
Mohd Alauddin Mohd Ali
CLChian Yong Liu
Chian Yong Liu
This paper presents a comparison between the electroencephalogram (EEG) channels during scoliosis correction surgeries. Surgeons use many hand tools and electronic devices that directly affect the EEG channels. These noises do not affect the EEG channels uniformly. This research provides a complete system to find the least affected channel by the noise. The presented system consists of five stages: filtering, wavelet decomposing (Level 4), processing the signal bands using four different criteria (mean, energy, entropy and standard deviation), finding the useful channel according to the criteria’s value and, finally, generating a combinational signal from Channels 1 and 2. Experimentally, two channels of EEG data were recorded from six patients who underwent scoliosis correction surgeries in the Pusat Perubatan Universiti Kebangsaan Malaysia (PPUKM) (the Medical center of National University of Malaysia). The combinational signal was tested by power spectral density, cross-correlation function and wavelet coherence. The experimental results show that the system-outputted EEG signals are neatly switched without any substantial changes in the consistency of EEG components. This paper provides an efficient procedure for analyzing EEG signals in order to avoid averaging the channels that lead to redistribution of the noise on both channels, reducing the dimensionality of the EEG features and preparing the best EEG stream for the classification and monitoring stage.

1 January 2007
Verified
Conference Paper
Closed access
AAAli O Al-Mathnani
Ali O Al-Mathnani
AMAzah Mohamed
Azah Mohamed
MAMohd Alauddin Mohd Ali
Mohd Alauddin Mohd Ali
Dynamic voltage restorer (DVR) is a custom power device used for mitigating voltage sags in power distribution systems. This paper presents a simulation model of a 12-pulse DVR using photovoltaic as a means of providing an alternative energy source for the DVR. For the development of DVR model, two models were considered by using user-defined model and existing component model. To achieve stable characteristic of the DVR, a feedback control loop is employed so as to achieve a faster response in sag detection and mitigation capability. Simulations were carried out using the PSCAD/EMTDC electromagnetic transient program to validate the capabilities of the photovoltaic-based DVR in performing voltage sag mitigation. Simulation results proved the capability of the photovoltaic-based DVR in mitigating voltage sag in a distribution system.

1 December 2015 in Metrology and Measurement Systems
Verified
Journal Article
Open access
PDF file
MMMohamad Fakhari Mehrjardi
Mohamad Fakhari Mehrjardi
HSHilmi Sanusi
Hilmi Sanusi
MAMohd. Alauddin Mohd. Ali
Mohd. Alauddin Mohd. Ali
Estimation of satellite three-axis attitude using only one sensor data presents an interesting estimation problem. A flexible and mathematically effective filter for solving the satellite three-axis attitude estimation problem using two-axis magnetometer would be a challenging option for space missions which are suffering from other attitude sensors failure. Mostly, magnetometers are employed with other attitude sensors to resolve attitude estimation. However, by designing a computationally efficient discrete Kalman filter, full attitude estimation can profit by only two-axis magnetometer observations. The method suggested solves the problem of satellite attitude estimation using linear Kalman filter (LKF). Firstly, all models are generated and then the designed scenario is developed and evaluated with simulation results. The filter can achieve 10e-3 degree attitude accuracy or better on all three axes.