Yutong Zhai

Mr. Yutong Zhai


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 September 2022 in Materials
Verified
Journal Article
Open access
PDF file
XHXuegong Huang
Xuegong Huang
YZYutong Zhai
Yutong Zhai
GHGuisong He
Guisong He
The vibration and impact of a humanoid bipedal robot during movements such as walking, running and jumping may cause potential damage to the robot’s mechanical joints and electrical systems. In this paper, a composite bidirectional vibration isolator based on magnetorheological elastomer (MRE) is designed for the cushioning and damping of a humanoid bipedal robot under foot contact forces. In addition, the vibration isolation performance of the vibration isolator was tested experimentally, and then, a vibration isolator dynamics model was developed. For the bipedal robot foot impact, based on the vibration isolator model, three vibration reduction control algorithms are simulated, and the results show that the vibration damping effect can reach 85%. Finally, the MRE vibration isolator hardware-in-the-loop-simulation experiment platform based on dSPACE has been built to verify the vibration reduction control effect of the fuzzy PID algorithm. The result shows the vibration amplitude attenuates significantly, and this verifies the effectiveness of the fuzzy PID damping control algorithm.

27 November 2025 in Robotica
Verified
Journal Article
Closed access
PDF file
XHXuegong Huang
Xuegong Huang
ZGZijun Guo
Zijun Guo
YZYutong Zhai
Yutong Zhai
Lower limb-assisted exoskeletons can provide payloads and support, but the hip joints of current lower limb-assisted exoskeletons have problems such as single mechanisms, few degrees of freedom, and limitations in the types of gaits that can be acted upon. To address these problems, a novel double-cam hip joint assist mechanism is proposed for walking, running, and carrying gait situations. The double cam and two rectangular compression springs with different stiffness are used to satisfy the differences in exoskeleton assistance requirements in multiple gaits. First, biomechanical simulation of walking, running, and carrying movements is carried out with OpenSim to obtain the hip joint angle and torque data, and then the structural design of the assist mechanism is carried out. Hip joint angle planning and contour solving are carried out for the contour lines of the cams, so that the cam contour lines are assist according to different hip joint angles, and the stiffness of compression springs is determined by D’Alembert’s principle, and the assist torques are analyzed. Meanwhile, a human–machine coupling model was established for theoretical analysis. Finally, the muscle power change curves were exported using OpenSim, and the assistance was verified by comparison.

1 December 2025 in Physica Scripta
Verified
Journal Article
Closed access
XHXuegong Huang
Xuegong Huang
ZGZijun Guo
Zijun Guo
YZYutong Zhai
Yutong Zhai
Manual carrying tasks subject the spine to high external loads, resulting in excessive joint torques and an increased risk of injury. Wearable exoskeletons provide an effective way to solve this problem. However, most existing exoskeletons are designed with rigid linkages, which restricts the natural movement of the human body. B ased on the unique anatomical structure of the human spine and dynamic bending mechanisms, this study proposes a novel multi-jointed passive bionic spinal exoskeleton characterized by a five-segment serial elastic unit structure. This design significantly enhances compliance and flexibility in sagittal, coronal, and transverse plane movements, enabling the exoskeleton to better match the natural activities of the human spine. First, we performed a biomechanical simulation of the carrying maneuvers using OpenSim to obtain data on the flexion angles of the major joints. Second, we conducted the structural design of the bionic spine, determined the stiffness of its elastic elements using the static method, and derived its kinematic model using the D-H coordinate analysis method. Concurrently, a human-machine coupled model was established for dynamic analysis. Finally, OpenSim was used to derive the muscle power change curves for a comparative verification of the exoskeleton’s good assisting effect.