Sam Stephens

Mr. Sam Stephens

University of Arkansas at Fayetteville, Fayetteville, Arkansas, USA
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 June 2021 in Cardiovascular Engineering and Technology
Verified
Journal Article
Open access
PDF file
MLMegan E. Laughlin
Megan E. Laughlin
SSSam Stephens
Sam Stephens
JHJamie A. Hestekin
Jamie A. Hestekin
MJMorten O Jensen
Morten O Jensen
Purpose: Flow phantoms are used in experimental settings to aid in the simulation of blood flow. Custom geometries are available, but current phantom materials present issues with degradability and/or mimicking the mechanical properties of human tissue. In this study, a method of fabricating custom wall-less flow phantoms from a tissue-mimicking gel using 3D printed inserts is developed. Methods: A 3D blood vessel geometry example of a bifurcated artery model was 3D printed in polyvinyl alcohol, embedded in tissue-mimicking gel, and subsequently dissolved to create a phantom. Uniaxial compression testing was performed to determine the Young’s moduli of the five gel types. Angle-independent, ultrasound-based imaging modalities, Vector Flow Imaging (VFI) and Blood Speckle Imaging (BSI), were utilized for flow visualization of a straight channel phantom. Results: A wall-less phantom of the bifurcated artery was fabricated with minimal bubbles and continuous flow demonstrated. Additionally, flow was visualized through a straight channel phantom by VFI and BSI. The available gel types are suitable for mimicking a variety of tissue types, including cardiac tissue and blood vessels. Conclusion: Custom, tissue-mimicking flow phantoms can be fabricated using the developed methodology and have potential for use in a variety of applications, including ultrasound-based imaging methods. This is the first reported use of BSI with an in vitro flow phantom.

30 August 2017 in PLOS ONE
Verified
Journal Article
Open access
PDF file
SSSam Stephens
Sam Stephens
SLSerguei Liachenko
Serguei Liachenko
NINeil B Ingels
Neil B Ingels
JWJonathan F Wenk
Jonathan F Wenk
MJMorten O Jensen
Morten O Jensen
Imaging techniques of the mitral valve have improved tremendously during the last decade, but challenges persist. The delicate changes in annulus shape and papillary muscle position throughout the cardiac cycle have significant impact on the stress distribution in the leaflets and chords, thus preservation of anatomically accurate positioning is critical. The aim of this study was to develop an in vitro method and apparatus for obtaining high-resolution 3D MRI images of porcine mitral valves in both the diastolic and systolic configurations with physiologically appropriate annular shape, papillary muscle positions and orientations, specific to the heart from which the valve was harvested. Positioning and mounting was achieved through novel, customized mounting hardware consisting of papillary muscle and annulus holders with geometries determined via pre-mortem ultrasonic intra-valve measurements. A semi-automatic process was developed and employed to tailor Computer Aided Design models of the holders used to mount the valve. All valve mounting hardware was 3D printed using a stereolithographic printer, and the material of all fasteners used were brass for MRI compatibility. The mounted valves were placed within a clear acrylic case, capable of holding a zero-pressure and pressurized liquid bath of a MRI-compatible fluid. Obtaining images from the valve submerged in liquid fluid mimics the natural environment surrounding the valve, avoiding artefacts due to tissue surface tension mismatch and gravitational impact on tissue shape when not neutrally buoyant. Fluid pressure was supplied by reservoirs held at differing elevations and monitored and controlled to within ±1mmHg to ensure that the valves remained steady. The valves were scanned in a 7 Tesla MRI system providing a voxel resolution of at least 80μm. The systematic approach produced 3D datasets of high quality which, when combined with physiologically accurate positioning by the apparatus, can serve as an important input for validated computational models.

3 August 2022 in Biomedicines
Verified
Journal Article
Open access
PDF file
Kayla WoodKayla Wood
Kayla Wood
SSSam Stephens
Sam Stephens
FXFeng Xu
Feng Xu
AHAlshaimaa Hazaa
Alshaimaa Hazaa
JMJames C. Meek
James C. Meek
SWSumith Ranil Wickramasinghe
Sumith Ranil Wickramasinghe
Strokes are among the leading causes of death worldwide. Ischemic stroke, due to plaque or other buildup blocking blood flow to the brain, is the most common type. Although ischemic stroke is treatable, current methods have severe shortcomings with high mortality rates. Clot retrieval devices, for example, can result in physically damaged vessels and death. This study aims to create blood clots that are representative of those found in vivo and demonstrate a new method of removing them. Static blood clots were formed using a 9:1 ratio of whole sheep blood and 2.45% calcium chloride solution. This mixture was heated in a water bath at 37 °C for approximately one hour until solidified. Following clot solidification, human plasmin was introduced by various methods, including soaking, injection, and membrane perfusion, and the resulting dissolution percentages were determined. Different clot types, representative of the wide range found physiologically, were also manufactured and their dissolution characteristics evaluated. A method to reproducibly create blood clots, characteristic of those found in vivo, is essential for the production of stroke retrieval devices that can efficiently and effectively remove clots from patients with low mortality rates and little/no damage to the surrounding vessels.

6 January 2022 in Journal of Cardiovascular Translational Research
Verified
Journal Article
Open access
PDF file
SSSam Stephens
Sam Stephens
AKAlexander J. Kammien
Alexander J. Kammien
JPJacob C. Paris
Jacob C. Paris
AAAlexis P. Applequist
Alexis P. Applequist
NINeil B. Ingels
Neil B. Ingels
MJMorten O Jensen
Morten O Jensen
Current in vitro models of the left heart establish the pressure difference required to close the mitral valve by sealing and pressurizing the ventricular side of the valve, limiting important access to the subvalvular apparatus. This paper describes and evaluates a system that establishes physiological pressure differences across the valve using vacuum on the atrial side. The subvalvular apparatus is open to atmospheric pressure and accessible by tools and sensors, establishing a novel technique for experimentation on atrioventricular valves. Porcine mitral valves were excised and closed by vacuum within the atrial chamber. Images were used to document and analyze closure of the leaflets. Papillary muscle force and regurgitant flow rate were measured to be 4.07 N at 120 mmHg and approximately 12.1 ml/s respectively, both of which are within clinically relevant ranges. The relative ease of these measurements demonstrates the usefulness of improved ventricular access at peak pressure/force closure. Graphical abstract

27 April 2020 in Communications Materials
Verified
Journal Article
Open access
PDF file
CHChrista N. Hestekin
Christa N. Hestekin
JHJamie A. Hestekin
Jamie A. Hestekin
SPSadia Paracha
Sadia Paracha
GMGrace Morrison
Grace Morrison
EPEfecan Pakkaner
Efecan Pakkaner
Ira KurtzIra Kurtz
Ira Kurtz
Current approaches for treating patients with end stage renal disease include hemodialysis and peritoneal dialysis, both of which are diffusion-based treatments that require a dialysate solution. The native kidney has separate filtration (glomerulus) and transport (nephron) capabilities. Although artificial methods for simulating glomerular function using membrane ultrafiltration have been proposed, there are no known technologies for simulating the ion transport functions of the nephron. Here we have created a synthetic nephron using activated wafer electrodeionization (AWEDI). AWEDI incorporates mesh electrodes within an electrodeionization wafer, allowing ion selectivity and transport rate to be modulated independently. We demonstrate the capabilities of AWEDI with several physiologically relevant ions which mimic the fine control of ion transport by the kidney. Furthermore, by integrating our AWEDI technology with ultrafiltration, nanofiltration, and reverse osmosis modules, the possibility of incorporating AWEDI technology in an artificial kidney is demonstrated.

15 July 2023 in Biomedical Signal Processing and Control
Verified
Journal Article
Closed access
AHAbul Hayat
Abul Hayat
JWJingxian Wu
Jingxian Wu
SSSam Stephens
Sam Stephens
HJHanna K. Jensen
Hanna K. Jensen
AVAdrià A. Villafranca
Adrià A. Villafranca
MJMorten O. Jensen
Morten O. Jensen