2 June 2021 in Cardiovascular Engineering and Technology
Purpose: Flow phantoms are used in experimental settings to aid in the simulation of blood flow. Custom geometries are available, but current phantom materials present issues with degradability and/or mimicking the mechanical properties of human tissue. In this study, a method of fabricating custom wall-less flow phantoms from a tissue-mimicking gel using 3D printed inserts is developed. Methods: A 3D blood vessel geometry example of a bifurcated artery model was 3D printed in polyvinyl alcohol, embedded in tissue-mimicking gel, and subsequently dissolved to create a phantom. Uniaxial compression testing was performed to determine the Young’s moduli of the five gel types. Angle-independent, ultrasound-based imaging modalities, Vector Flow Imaging (VFI) and Blood Speckle Imaging (BSI), were utilized for flow visualization of a straight channel phantom. Results: A wall-less phantom of the bifurcated artery was fabricated with minimal bubbles and continuous flow demonstrated. Additionally, flow was visualized through a straight channel phantom by VFI and BSI. The available gel types are suitable for mimicking a variety of tissue types, including cardiac tissue and blood vessels. Conclusion: Custom, tissue-mimicking flow phantoms can be fabricated using the developed methodology and have potential for use in a variety of applications, including ultrasound-based imaging methods. This is the first reported use of BSI with an in vitro flow phantom.
5 March 2022 in Phlebology: The Journal of Venous Disease
Objective: Bioprosthetic venous valves have yet to achieve long-term patency due to issues with calcification following implantation that is influenced by current xenograft fixation methods, most notably glutaraldehyde. The goal of this study was to investigate the effects of glutaraldehyde fixation on the functional properties of venous tissue to establish a benchmark for the evaluation of alternative fixation methods. Methods: The degree of crosslinking was evaluated by determining shrink temperature and the stability of tissue with pronase and collagenase digestion. Results: Glutaraldehyde fixation of venous tissue was confirmed by a significant difference in the shrink temperature between fresh and glutaraldehyde treated samples. Significant differences in the amount of tissue remaining following digestion were observed for venous versus cardiac tissue. Conclusions: This study demonstrates the importance of tissue-specific evaluation in the development of alternative xenograft fixation methods to improve outcomes with bioprosthetic venous valves.