Yuanjun Guo

Dr. Yuanjun Guo

School of Physics, University of Electronic Science and Technology of China, Chengdu 610054, China

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 March 2023 in Journal of Materials Chemistry A
Verified
Journal Article
Closed access
PDF file
XLXue Li
Xue Li
WSWenfeng Sun
Wenfeng Sun
WFWei Fu
Wei Fu
HLHaifeng Lv
Haifeng Lv
XZXiaotao Zu
Xiaotao Zu
RFRichard Fu
Richard Fu
Surface acoustic wave (SAW) technology has been extensively used in communications and sensing applications. This review summarizes the recent advancement of micro- and nanostructured sensing materials in enhancing the gas sensing performance of SAW devices.

1 April 2020 in Journal of Hazardous Materials
Verified
Journal Article
Closed access
JWJ.L. Wang
J.L. Wang
YGYuanjun Guo
Yuanjun Guo
GLG.D. Long
G.D. Long
Yongliang TangYongliang Tang
Yongliang Tang
QTQ.B. Tang
Q.B. Tang
RFRichard Fu
Richard Fu

13 June 2019 in Journal of Materials Science
Verified
Journal Article
Closed access
PDF file
QTQ. B. Tang
Q. B. Tang
YGYuanjun Guo
Yuanjun Guo
Yongliang TangYongliang Tang
Yongliang Tang
GLG. D. Long
G. D. Long
JWJ. L. Wang
J. L. Wang
RFRichard Fu
Richard Fu

15 April 2025 in Advanced Materials
Verified
Journal Article
Closed access
XHXiang‐Long Huang
Xiang‐Long Huang
YGYuanjun Guo
Yuanjun Guo
LZLingfei Zhao
Lingfei Zhao
LYLong Yao
Long Yao
KZKunjie Zhu
Kunjie Zhu
HLHua Liu
Hua Liu

23 July 2020 in Smart Materials and Structures
Verified
Journal Article
Closed access
PDF file
YGYuanjun Guo
Yuanjun Guo
GLGongdi Long
Gongdi Long
YTYongliang Tang
Yongliang Tang
JWJinlong Wang
Jinlong Wang
QTQingbo Tang
Qingbo Tang
YFYong Qing (Richard) Fu
Yong Qing (Richard) Fu
Sensitive thin film layers of SnO 2 , SiO 2 and SiO 2 –SnO 2 were deposited on a surface acoustic wave resonator using sol-gel method and spin coating techniques. Their ammonia-sensing performance operated at room temperature was characterized and their sensing mechanisms were comprehensively studied. When exposed to ammonia, the sensors made of SnO 2 and SiO 2 –SnO 2 films exhibit positive frequency shifts, whereas the SiO 2 film sensors exhibit a negative frequency shift. The positive frequency shift is related to the dehydration and condensation of hydroxyl groups, which makes the films stiffer and lighter. The negative frequency shift is mainly caused by the increase of mass loading due to the adsorption of ammonia. The gas sensor based on SiO 2 –SnO 2 film shows a positive frequency shift of 631 Hz when it is exposed to ammonia with a low concentration of 3 ppm, and it also shows good repeatability and stability, as well as a good selectivity to ammonia compared with gases of C 6 H 14 , C 2 H 5 OH, C 3 H 6 O, CO, H 2 , NO 2 , and CH 4 .

16 March 2020 in Smart Materials and Structures
Verified
Journal Article
Closed access
PDF file
JWJinlong Wang
Jinlong Wang
YGYuanjun Guo
Yuanjun Guo
DLDengji Li
Dengji Li
GLGongdi Long
Gongdi Long
QTQingbo Tang
Qingbo Tang
RFRichard Fu
Richard Fu
A Love mode surface acoustic wave (SAW) humidity sensor based on bacterial cellulose (BC) coated ST-cut quartz was developed in this study. The BC film is composed of ultrafine interwoven fibers to form a highly porous network, and its surface contains a large amount of hydroxyl groups, which significantly improve the adsorption capability of SAW sensing layer for water molecules. This results in significant mass loading effects and enhanced responsivity of the SAW sensor. The resonant frequency of the sensor changes linearly with RH at lower relative humidity (RH) values (e.g. RH < 30%), but when RH > 80%, an exponential increase in frequency shift as a function of RH is obtained due to the enhanced mass loading effect. A frequency shift of 89.8 kHz was measured using a sensor with a BC film with a thickness of 148 nm thick when the RH was increased from 30% to 93%. The frequency of the sensor can be fully shifted back to the original reading when the RH was returned back to 30%, with the response and recovery times of 12 s and 5 s, respectively. The SAW sensor also exhibits good short-term repeatability and long-term stability for humidity sensing.