Chayakorn Petchakup

Mr. Chayakorn Petchakup


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 March 2017 in Micromachines
Verified
Journal Article
Open access
PDF file
CPChayakorn Petchakup
Chayakorn Petchakup
Holden LiHolden Li
Holden Li
HHHan Wei Hou
Han Wei Hou
Microfluidics impedance cytometry is an emerging research tool for high throughput analysis of dielectric properties of cells and internal cellular components. This label-free method can be used in different biological assays including particle sizing and enumeration, cell phenotyping and disease diagnostics. Herein, we review recent developments in single cell impedance cytometer platforms, their biomedical and clinical applications, and discuss the future directions and challenges in this field.

21 July 2017
Verified
Conference Paper
Open access
Holden LiHolden Li
Holden Li
CPChayakorn Petchakup
Chayakorn Petchakup
HTHui Min Tay
Hui Min Tay
NMNishanth Venugopal Menon
Nishanth Venugopal Menon
HHHan Wei Hou
Han Wei Hou
Monocytes represent a highly heterogeneous leukocyte population with the ability to differentiate into macrophages, a major cell type involved in the pathogenesis of atherosclerotic plaque in cardiovascular diseases [1,2]. Label-free analysis of their native cellular phenotypes and functions not only reduces assay cost and time, but is also essential for understanding disease progression and development of novel therapeutic strategies. Impedance cytometry is an emerging technology for high throughput cell phenotyping based on intrinsic electrical properties without the use of antibodies [3,4]. While parallel electrodes offer higher detection sensitivity as compared to co-planar electrodes [3,4], it is limited by laborious microfabrication. Herein, we present the development of an efficient microfluidics impedance cytometer using coplanar electrodes for rapid monocyte identification and phenotyping based on differentiation status. The microfluidics impedance cytometer consists of a two-inlet, two-outlet polydimethylsiloxane (PDMS) microchannel (30 μm (width) × 20 μm (height)) bonded on patterned coplanar electrodes (20 μm in width with 20 μm separation gap). Sample and sheath fluid are injected into the device to hydrodynamically focus the cells at the channel center prior electrical detection. As the cell moves through the detection region, it disrupts the electric field generated by coplanar electrodes, thereby causing a change in electrical impedance. Using our setup (Fig. 1), the change in electrical impedance was quantified based on current change, and various cellular information were extracted at different frequencies of the excitation signal. We measured two impedance parameters namely the 1) opacity (ratio of impedance magnitude at 0.3MHz (|ZLF|) to impedance magnitude at 1.7MHz (|ZHF|)) which reflects cell membrane capacitance, and 2) |ZLF| which characterize cell size. For identification of different blood cell types, human monocytes and lymphocytes purified using Dean Flow Fractionation (DFF) [5], and diluted red blood cells (RBCs) samples were separately injected into the microdevice. As shown in figure 2, different cell types were clearly differentiated based on |ZLF| due to distinct cell size differences (monocytes: 10 – 12 µm, lymphocytes: 7 – 8 µm, and red blood cells: 6 – 8 µm). Characterization of primary monocytes and leukemic THP-1 monocytic cell line also showed distinct differences in size and opacity (Fig. 3). Lastly, we compared the impedance profile of THP-1 and differentiated macrophages (PMA stimulated), and found that macrophages were more heterogeneous in size with significantly lower opacity than THP-1, demonstrating the feasibility of real-time assessment of monocyte differentiation using impedance-based sensing (Fig. 4). In conclusion, the developed microdevice enables continuous label-free monocyte phenotyping using coplanar electrodes configuration with sufficient sensitivity. With the design simplicity and low cost fabrication, we envision our method will greatly facilitate immunology research and point-of-care monocyte profiling in patients with cardiovascular diseases.