Hui Min Tay

Ms. Hui Min Tay


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 December 2021 in Biosensors
Verified
Journal Article
Open access
PDF file
CSChengxun Su
Chengxun Su
YCYon Jin Chuah
Yon Jin Chuah
HOHong Boon Ong
Hong Boon Ong
HTHui Min Tay
Hui Min Tay
RDRinkoo Dalan
Rinkoo Dalan
HHHan Wei Hou
Han Wei Hou
Incorporation of extracellular matrix (ECM) and hydrogel in microfluidic 3D cell culture platforms is important to create a physiological microenvironment for cell morphogenesis and to establish 3D co-culture models by hydrogel compartmentalization. Here, we describe a simple and scalable ECM patterning method for microfluidic cell cultures by achieving hydrogel confinement due to the geometrical expansion of channel heights (stepped height features) and capillary burst valve (CBV) effects. We first demonstrate a sequential “pillar-free” hydrogel patterning to form adjacent hydrogel lanes in enclosed microfluidic devices, which can be further multiplexed with one to two stepped height features. Next, we developed a novel “spheroid-in-gel” culture device that integrates (1) an on-chip hanging drop spheroid culture and (2) a single “press-on” hydrogel confinement step for rapid ECM patterning in an open-channel microarray format. The initial formation of breast cancer (MCF-7) spheroids was achieved by hanging a drop culture on a patterned polydimethylsiloxane (PDMS) substrate. Single spheroids were then directly encapsulated on-chip in individual hydrogel islands at the same positions, thus, eliminating any manual spheroid handling and transferring steps. As a proof-of-concept to perform a spheroid co-culture, endothelial cell layer (HUVEC) was formed surrounding the spheroid-containing ECM region for drug testing studies. Overall, this developed stepped height-based hydrogel patterning method is simple to use in either enclosed microchannels or open surfaces and can be readily adapted for in-gel cultures of larger 3D cellular spheroids or microtissues.

21 July 2017
Verified
Conference Paper
Open access
HHHan Wei Hou
Han Wei Hou
HTHui Min Tay
Hui Min Tay
SKSharad Kharel
Sharad Kharel
Joachim LooJoachim Loo
Joachim Loo
Herein, we introduce a novel Dean migration phenomenon in spiral microchannel, termed High-resolution Dean Flow Fractionation (HiDFF), for separation of small microparticles based on differential Dean migration profiles. Inertial microfluidics is an emerging class of passive size-based sorting technique for cell separation [1,2]. However, inertial focusing of small microparticles (particle size, ap < 1-2 µm) remains a huge technical challenge as channel dimensions have to be scaled down (hydraulic diameter, Dh ~10 µm) for them to experience significant inertial forces (FL) and undergo lateral migration. Our group previously developed a spiral microfluidics sorter (Dean Flow Fractionation, DFF) which enables well-controlled, Dean-induced lateral migration of small particles including bacteria [3], nanoparticles [4] and biomolecules [5] to channel outer wall while target cells (>10 µm) focus near inner wall for separation. However, it cannot further size-fractionate small particles (1 µm vs. 2 µm) as they would recirculate continuously due to Dean vortices. Using HiDFF, we were able to demonstrate efficient separation of 1–3 µm microbeads mixture, and then apply the technology to size-fractionate different small biological components including bacteria and nanoparticles. The 2-inlet, 2-outlet spiral microdevice (60×300 µm (H×W)) is fabricated using polydimethylsiloxane (PDMS) (Fig. 1A). Small particles (ap/ Dh <0.07) introduced at channel outer wall experience Dean drag forces (FD) due to Dean vortices and migrate laterally towards inner wall (Fig. 1B). Near the inner wall, particles occupy different innermost transient positions under influence of size-dependent wall-induced inertial lift force (FWL) (Fig. 1C). Hence, smaller particles are positioned closer to inner wall and separated into the inner outlet (outlet 1) while larger particles are sorted into outer outlet (outlet 2). We first used 50 nm fluorescent polystyrene microbeads to study the lateral migration of small particles at different channel positions. Particles migrated along the channel top and bottom towards inner wall, and recirculated outwards as a tight band along the channel midline (Fig. 2A). Interestingly, the innermost transient particle position moved further away from inner wall with increasing particle size at same flow conditions, which led to distinct transient positions for each particle size (50 nm–3 µm) (Fig. 2B). We next characterized the separation efficiencies of different binary bead mixtures including 2 and 3 µm, and 1 and 2 µm beads (Fig. 3). Approximately 20% of the smaller particles were sorted into outlet 1 which resulted in a ~10 to 30–fold enrichment. Lastly, we used the developed HiDFF technology to size-fractionate Escherichia coli (E. coli) and Poly(lactic-co-glycolic acid) nanoparticles (PLGA NPs) into 2 different size groups (Fig. 4), and verified the particle size distribution using optical imaging and scanning electron microscope (SEM). Currently, there is a critical need for small particle sorting which is important in applications ranging from material sciences, environmental bio-sampling to bacterial/exosomes clinical diagnostics. The developed HiDFF technology represents an important progress towards this goal, as it enables high throughput (~100 µLmin-1) membrane-free separation of small particles (<1 µm), and can be easily integrated to existing point-of-care platforms for small biological targets purification and detection.

21 July 2017
Verified
Conference Paper
Open access
Holden LiHolden Li
Holden Li
CPChayakorn Petchakup
Chayakorn Petchakup
HTHui Min Tay
Hui Min Tay
NMNishanth Venugopal Menon
Nishanth Venugopal Menon
HHHan Wei Hou
Han Wei Hou
Monocytes represent a highly heterogeneous leukocyte population with the ability to differentiate into macrophages, a major cell type involved in the pathogenesis of atherosclerotic plaque in cardiovascular diseases [1,2]. Label-free analysis of their native cellular phenotypes and functions not only reduces assay cost and time, but is also essential for understanding disease progression and development of novel therapeutic strategies. Impedance cytometry is an emerging technology for high throughput cell phenotyping based on intrinsic electrical properties without the use of antibodies [3,4]. While parallel electrodes offer higher detection sensitivity as compared to co-planar electrodes [3,4], it is limited by laborious microfabrication. Herein, we present the development of an efficient microfluidics impedance cytometer using coplanar electrodes for rapid monocyte identification and phenotyping based on differentiation status. The microfluidics impedance cytometer consists of a two-inlet, two-outlet polydimethylsiloxane (PDMS) microchannel (30 μm (width) × 20 μm (height)) bonded on patterned coplanar electrodes (20 μm in width with 20 μm separation gap). Sample and sheath fluid are injected into the device to hydrodynamically focus the cells at the channel center prior electrical detection. As the cell moves through the detection region, it disrupts the electric field generated by coplanar electrodes, thereby causing a change in electrical impedance. Using our setup (Fig. 1), the change in electrical impedance was quantified based on current change, and various cellular information were extracted at different frequencies of the excitation signal. We measured two impedance parameters namely the 1) opacity (ratio of impedance magnitude at 0.3MHz (|ZLF|) to impedance magnitude at 1.7MHz (|ZHF|)) which reflects cell membrane capacitance, and 2) |ZLF| which characterize cell size. For identification of different blood cell types, human monocytes and lymphocytes purified using Dean Flow Fractionation (DFF) [5], and diluted red blood cells (RBCs) samples were separately injected into the microdevice. As shown in figure 2, different cell types were clearly differentiated based on |ZLF| due to distinct cell size differences (monocytes: 10 – 12 µm, lymphocytes: 7 – 8 µm, and red blood cells: 6 – 8 µm). Characterization of primary monocytes and leukemic THP-1 monocytic cell line also showed distinct differences in size and opacity (Fig. 3). Lastly, we compared the impedance profile of THP-1 and differentiated macrophages (PMA stimulated), and found that macrophages were more heterogeneous in size with significantly lower opacity than THP-1, demonstrating the feasibility of real-time assessment of monocyte differentiation using impedance-based sensing (Fig. 4). In conclusion, the developed microdevice enables continuous label-free monocyte phenotyping using coplanar electrodes configuration with sufficient sensitivity. With the design simplicity and low cost fabrication, we envision our method will greatly facilitate immunology research and point-of-care monocyte profiling in patients with cardiovascular diseases.

21 July 2017
Verified
Conference Paper
Open access
HHHan Wei Hou
Han Wei Hou
HTHui Min Tay
Hui Min Tay
RDRinkoo Dalan
Rinkoo Dalan
BBBernhard Otto Boehm
Bernhard Otto Boehm
In this work, we introduce a novel microdevice capable of single-step neutrophil sorting from whole blood directly for multiplexed functional phenotyping (chemotaxis and NETosis) (Fig. 1A). Diabetes mellitus (DM) is a metabolic disorder characterized by chronic hyperglycaemia, resulting in increased oxidative stress, chronic low-grade inflammation and endothelial dysfunction [1]. Neutrophils are key effector cells of the innate immunity, and are known to play a pivotal role in diabetic pathophysiology [2]. However, study of neutrophil dysfunctions remains technically challenging due to difficulties in isolating “touch-free” neutrophils in their native state using conventional leukocyte isolation methods (density gradient centrifugation and blood lysis). Microfluidics technologies have been recently developed for neutrophil studies, but require additional leukocyte preparation or manual washing steps to efficiently purify neutrophils from whole blood [3, 4]. Herein, we report an integrated microfluidics biochip for single step neutrophil purification and functional phenotyping using small blood volume (fingerprick) for point-of-care diabetes testing. The microdevice is fabricated using polydimethylsiloxane (PDMS) and consists of a margination channel, 20×20 µm (W×H) with 2 side chambers 400×20 µm (W×H). As whole blood (~10 µL) is pumped through the straight channel, deformable red blood cells (RBCs) migrate laterally towards the axial centre (Fahraeus effect), resulting in margination of other cell types (platelets and leukocytes) into the smaller side channels (Fig. 1B). Neutrophils are selectively captured in the anti-CD66b-functionalized surface and then exposed to a stable diffusion-based gradient of either chemoattractant (fMLP) or calcium ionophore (AZ23187), to study chemotaxis or formation of neutrophil extracellular traps (NETosis) respectively (Fig. 1C). Time-lapse imaging and single cell image analysis are performed to probe chemotaxis (migrating cells and chemotactic velocity) and NETosis (nuclear membrane degradation) phenotypes. A 10-fold leukocyte enrichment was achieved at the side outlets (Fig. 2A) and leukocyte differential count using flow cytometry analysis also showed ~50% decrease in neutrophil concentration in the eluent collected from anti-CD66b-coated side outlets, indicating efficient on-chip neutrophil capture (Fig. 2B). We next measured the fluorescence intensity along the side chamber using FITC dye preloaded in the reservoir proximal to the connecting side channels, and linescans at various time points showed that the diffusion gradient remained linear and stable for 2 hours (Fig. 3B). For chemotaxis assay we successfully demonstrated migration of captured healthy neutrophils towards the chamber preloaded with fMLP (200 nM) within 2 hours (Fig. 3C). For NETosis assay, glucose-treated neutrophils (30 mM) exhibited an increase in NETosis (P < 0.05) than untreated and mannitol-treated (30 mM) neutrophils (Fig. 4A, B). The unique strategy of integrating microfluidic neutrophil sorting with cellular functional assays facilitates user operation and the developed diagnostic platform can be further advanced for point-of-care inflammatory profiling and precision medicine approaches. We envision that characterization of neutrophil chemotaxis in diabetes patients can provide direct evidence in microvascular compilations in diabetes and be used as surrogate biomarkers for monitoring endothelial dysfunction, arterial stiffness, peripheral markers of inflammation and oxidative stress in metabolic diseases.