Guan-Yuan WU

Prof. Guan-Yuan WU

Department of Fire Science, Central Police University

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 January 2004 in STRUCTURAL ENGINEERING AND MECHANICS
Verified
Journal Article
Closed access
YCYung-I Chen
Yung-I Chen
GWGuan-Yuan WU
Guan-Yuan WU

19 April 2013 in International Journal of Non-Linear Mechanics
Verified
Journal Article
Closed access
GWGuan-Yuan WU
Guan-Yuan WU

23 October 2009 in Journal of Sound and Vibration
Verified
Journal Article
Closed access
GWGuan-Yuan WU
Guan-Yuan WU

11 October 2010 in Journal of Combustion
Verified
Journal Article
Open access
PDF file
GWGuan-Yuan WU
Guan-Yuan WU
RCRuu-Chang Chen
Ruu-Chang Chen
This paper presents an investigation on the scenarios of the natural smoke filling times in an atrium due to a located floor fire. Based on the Heskestad's correlation, the heat release rate and the effective height of the fire source were transformed into an equation associated with the diameter and perimeter of the fire source. Neglecting the thermal effect for heat release due to relatively small temperature rise in the atrium and applying the assumption of mass conservation, the height of smoke layer interface can be derived. In this study, the various plume models such as McCaffrey's correlation, Zukoski's correlation, Thomas's correlation and NFPA 92B's correlation are considered with both steady fire and unsteady fire situations. The comparisons between the theoretical results and the experimental data were also made and discussed.

16 October 2023 in Indoor and Built Environment
Verified
Journal Article
Closed access
GWGuan-Yuan WU
Guan-Yuan WU
MMMasayuki Mizuno
Masayuki Mizuno
SPSeongKyung Park
SeongKyung Park
The main aim of this study is to investigate the numerical analysis of phased evacuation and validate the feasibility of high-rise buildings using the control volume model. Based on the same spatial configuration, the number of participants on each floor, and four-phased evacuations of an actual fire drill conducted by a Japanese academic group in 2018, the numerical analysis results for these phased evacuations of this high-rise building have been investigated. The numerical results are in good agreement with the fire drill data in the aspects of the total number of people reaching the ground floor, the space-time feature curve and the first participant on each floor descending to the ground floor. The changes in the number of waiting participants versus time on each floor were obtained and compared in this study with the fire drill data to comprehend the transient situations of the internal participants in this high-rise building during the phased evacuation. Furthermore, the results of the first-order approximation method of NFPA, the Melinek and Booth method and the Route B calculation of the Japanese Building Center Verification Method for the total building evacuation are presented to discuss the differences between the phased evacuation and the total building evacuation.

20 June 2024 in Indoor and Built Environment
Verified
Journal Article
Closed access
SPSeongKyung Park
SeongKyung Park
GWGuan-Yuan WU
Guan-Yuan WU
KFKosuke Fujii
Kosuke Fujii
MMMasayuki Mizuno
Masayuki Mizuno
In a fire, stairways are the primary avenues for building evacuation. Previous studies focused on investigating evacuation flow through evacuation drills in a high-rise office building to assess the accuracy of evacuation scenarios and compared them with evacuation dynamics. However, the effectiveness of evacuation drills in estimating many scenarios is limited by actual drills. The evacuation simulations present a promising approach to objectively evaluating evacuation scenarios. This study verifies whether evacuation simulations can faithfully replicate actual evacuation flow and effectively predict suitable evacuation scenarios or potentially involve parameter calibration. Through a comprehensive comparison analysis, this study scrutinized the reliability of evacuation simulations and calibrated the simulation parameters. The analysis revealed that factors, including adjustments to the door width, personal space considerations for occupants in both conflict and normal situations and variations in staircase structure configuration, can significantly influence the evacuation flow within staircases. Manipulating these parameters in simulations would enable a more precise replication of evacuation flow within staircases, thereby enhancing the simulation’s accuracy in target evacuation scenarios. The findings of this research have underscored the significance of employing advanced simulation techniques to model evacuation dynamics accurately, facilitating a robust framework for devising effective emergency evacuation strategies in high-rise office buildings.