Kestutis Miskinis

Dr. Kestutis Miskinis

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 August 2022 in Buildings
Verified
Journal Article
Open access
PDF file
RBRaimondas Bliūdžius
Raimondas Bliūdžius
KMKestutis Miskinis
Kestutis Miskinis
VBVincent Buhagiar
Vincent Buhagiar
Karolis BanionisKarolis Banionis
Karolis Banionis
Sound insulation design for structural glazed façade is an important task in environmental noise control, as increased continuously repeated noise is a significant factor impacting on people’s well-being and is associated with a negative impact on their health. For façades, in addition to sound insulation, requirements for safe use and high energy efficiency are also usually raised, which partly determine the composition of the glazing: triple insulating glass unit (IGU) with inner safety laminated glass sheet. Therefore, the aim of the research was to investigate the structural sealed façade structure with triple IGU and to determine the effect of the thickness of ordinary and laminated glasses, their position in the IGU, the thickness of the gas cavities, and the mass of the structural frame on the sound insulation level of structural glazing. Experimental measurements of the sound insulation index of the investigated façade elements with IGU of various constructions were performed in an acoustic reverberation chamber according to standard procedures. The result of the study indicated that the use of the second laminated glass in a triple IGU is inefficient, the highest sound insulation indicators are achieved by increasing the thicknesses of the external glass sheet and the gas cavity; increasing the mass of the frame also has only little effect on the sound insulation of the structural glazing.

3 August 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
VDVaida Dobilaitė
Vaida Dobilaitė
MJMilda Jucienė
Milda Jucienė
Karolis BanionisKarolis Banionis
Karolis Banionis
JKJurga Kumžienė
Jurga Kumžienė
VPValdas Paukštys
Valdas Paukštys
KMKestutis Miskinis
Kestutis Miskinis
It is important to develop research on sealing materials in order to find effective solutions to ensure the energy efficiency of buildings. The aim of this study is to investigate the peel adhesion of single-sided self-adhesive tapes to different construction surfaces and to determine the change in this characteristic due to climatic effects. Different construction tapes, mostly used externally in buildings, are glued to different substrates. The artificial aging of test samples was carried out, simulating the effects of moisture, heat, and cold; the intensity, duration, and sequence of the cyclic effects were determined, taking into account the statistical climatological data of the middle-latitude climate zone. The peel adhesion of the tapes was determined before and after different numbers of artificial aging cycles. The results show that the peel adhesion range is very wide, from 11 to 61 N/24 mm. In most cases, a lower-rated peeling adhesion was obtained by peeling the tape from plastered cement–sawdust board. The change in peel adhesion depends more on the surface to which the tape is glued than it does on the number of climatic exposure cycles selected for the test.

17 July 2020 in Proceedings
Verified
Conference Paper
Open access
PDF file
Rosita NorvaisieneRosita Norvaisiene
Rosita Norvaisiene
PKPaweł Krause
Paweł Krause
VBVincent Buhagiar
Vincent Buhagiar
ABArūnas Burlingis
Arūnas Burlingis
KMKestutis Miskinis
Kestutis Miskinis
This paper is the research output of the laboratory ageing of external thermal insulation composite systems (ETICS). This was carried out in order to study the changes in properties of systems consisting of combustible and non-combustible thermal insulation materials, and four different types of finishing renders. Four types of the widely used, thin-layer facade rendering systems were subjected to hydrothermal cycles in a climate chamber in conformity with ETAG 004 guidelines. Analysis of the physical and mechanical properties (i.e., variation of temperature, water absorption, bond strength and mechanical resistance) of four types of ETICS are presented. This study indicates that there are no visible defects on any renderings over the junctions between polystyrene foam (EPS) and mineral wool (MW) materials when applied in ETICS.

1 September 2026 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
KMKestutis Miskinis
Kestutis Miskinis
VPValdas Paukštys
Valdas Paukštys
Since 2006, requirements for the energy efficiency of buildings have been introduced in Lithuania. Buildings have been divided into energy efficiency classes from “F” (least efficient) to “A++” (most efficient). All new buildings constructed after 1st of January 2021 must fulfil the requirements of the “A++” energy efficiency class. Meanwhile, old buildings (built before 1990) usually meet only the requirements of the lowest “F” class. Currently, these buildings are encouraged to be renovated (modernised) to meet at least the requirements of the “B” energy efficiency class. The aim of the study was to determine which measures can be applied to ensure that modernized buildings meet these “B” class requirements. As the study showed, improved energy efficiency of a building is achieved by adding appropriate thermal insulation, replacing windows and doors and ensuring the tightness of the building envelope. Furthermore, the study showed that airtightness is important factor which could influence energy class of building. The airtightness depends on defects of windows and door, plumbing and electricity installation, wall junction, socle and roof.

20 October 2025 in Buildings
Verified
Journal Article
Open access
PDF file
KMKestutis Miskinis
Kestutis Miskinis
MZMindaugas Zilys
Mindaugas Zilys
MJMilda Jucienė
Milda Jucienė
VDVaida Dobilaitė
Vaida Dobilaitė
The ventilation system is one of the most important elements of a building for the appropriate insurance of indoor climate parameters. Nowadays, textile ventilation systems are increasingly being used as a solution for low-energy buildings. Greater air movement and distribution in ventilation systems often leads to one of the most noticeable issues for people—increased noise in the indoor environment. One of the solutions is to use noise reducing diffusers. The aim of this research was to design and test a diffuser that fulfills noise regulations, would be light (weight less than 3 kg), be able to flexibly change geometry and have a design that harmonizes with the interior design, could be easily installed into a suspended ceiling, have a simple connection to the ventilation duct and be able to be effortlessly removed for maintenance, and be sustainable (usage of recycled materials). Three types of diffusers were created according to set characteristics and tested. The test results showed that the aim of the research was achieved—the emitted noise levels are below the regulation’s required level of less than 45 dBA. Also, it is light—the weight is 1.7 kg and 2.8 kg, respectively, for square and rectangular diffusers; has a flexible construction and design; is made from recycled materials.

9 January 2026 in Textiles
Verified
Journal Article
Open access
PDF file
MJMilda Jucienė
Milda Jucienė
VDVaida Dobilaitė
Vaida Dobilaitė
KMKestutis Miskinis
Kestutis Miskinis
VPValdas Paukštys
Valdas Paukštys
The problem of textile industry waste has become increasingly relevant. Recycling clothing industry waste to build acoustic panels is one of the most popular and relatively inexpensive ways to use clothing industry waste. We see a lack of information on the acoustic properties of panels made from waste from the clothing industry. The aim of this research is to determine the acoustic properties of a wide range of clothing industry waste recycled into acoustic panels. The acoustic panels were made from clothing industry waste, a different composition of textile and paper residues generated during digital printing processes. We see that panels made from square-cut scraps knitted and woven fabrics, and from yarns and fibers have relatively good acoustic properties. The panel made only of paper had good acoustic properties, the production of panels from paper and textile resulted in similar acoustic properties. Analyzing the acoustic properties of the double specimen, it was found that testing the double-layered panels, the insertion loss is better; by tripling the samples, it was found that although the acoustic properties improved, they were only marginal. Cellulose fiber boards were characterized by significantly higher air resistance. The air resistance of the boards made from fabric scraps was lower.