Karolis Banionis

Dr. Karolis Banionis

Kaunas University of Technology, Institute of Architecture and Construction
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 August 2014 in Energies
Verified
Journal Article
Open access
PDF file
JŠJolanta Šadauskienė
Jolanta Šadauskienė
VPValdas Paukštys
Valdas Paukštys
Lina SeduikyteLina Seduikyte
Lina Seduikyte
Karolis BanionisKarolis Banionis
Karolis Banionis
In order to fulfil the European Energy Performance of Buildings Directive (EPBD) requirements for the reduction of energy consumption, European national requirements have been created for building envelope thermal properties and calculation methodology to determine if building energy efficiency is created. This is however not true in all methodologies. The necessity of building air tightness appears only for new A class buildings, and there are no requirements for air tightness for other building classes. Therefore, the aim of this work is to improve the methodology for the calculation of energy efficiency of buildings, while taking into account the air tightness of the buildings. In order to achieve this aim, the sum energy consumption of investigated buildings was calculated, energy efficiency classes were determined, air tightness of the buildings was measured, and reasons for insufficient air tightness were analyzed. Investigation results show that the average value of air tightness of A energy efficiency class buildings is 0.6 h−1. The results of other investigated buildings, corresponding to B and C energy efficiency classes, show insufficient air tightness (the average n50 value is 6 h−1); herewith, energy consumption for heating is higher than calculated, according to the energy efficiency methodology. This paper provides an energy performance evaluation scheme, under which performed evaluation of energy performance of buildings ensures high quality construction work, building durability, and the reliability of heat-loss calculations.

18 March 2021 in Energies
Verified
Journal Article
Open access
PDF file
Karolis BanionisKarolis Banionis
Karolis Banionis
JKJurga Kumžienė
Jurga Kumžienė
ABArūnas Burlingis
Arūnas Burlingis
JRJuozas Ramanauskas
Juozas Ramanauskas
VPValdas Paukštys
Valdas Paukštys
Windows, which have a U-value that is governed by an insulating glass unit (IGU) U-value, must be a building’s only enclosure element, which has no design value concept. The declared U-value, which is calculated or measured with 0 °C of external ambient temperature, is used instead of the design value. For most of a building’s elements, its thermal transmittance with a decrease in the external temperature diminishes a little, i.e., improves. However, for modern window IGUs with Low-E coatings, it is the opposite: the thermal transmittance with a lowering external temperature increases. Therefore, for calculating the peak power for the heating of buildings it is necessary to pay attention to this phenomenon and, therefore, it would be wise to introduce the concept of design U-value for windows, recalculation rules, or affix their declared U-values. This is especially the case in modern times with the prevailing architectural tendencies for enlargement of transparent building elements. For IGUs with Low-E coatings and inert gas fillers, the thermal transmittance depends on the temperature difference between warm and cold environments. When the external temperature is −30 °C instead of 0 °C, the thermal transmittance of the IGU can increase by up to 35%. This study presents the thermal properties of windows’ IGUs depending on the changes in outdoor temperatures by using guarded a hot box climate chamber and presents the proposed simplified methodology for determining the thermal properties of windows’ glass units. The accuracy of the composed simplified methods, comparing the calculated thermal transmittances of IGUs with those measured in the “hot box”, were up to 1.25%.

27 July 2023 in Buildings
Verified
Journal Article
Open access
PDF file
APAleksejs Prozuments
Aleksejs Prozuments
Anatolijs BorodinecsAnatolijs Borodinecs
Anatolijs Borodinecs
SZSergejs Zaharovs
Sergejs Zaharovs
Karolis BanionisKarolis Banionis
Karolis Banionis
EMEdmundas Monstvilas
Edmundas Monstvilas
Rosita NorvaisieneRosita Norvaisiene
Rosita Norvaisiene
Currently, the optimization of thermal energy consumption in buildings is considered a suitable alternative in the construction of new buildings, as a result of which the overall energy efficiency of the building increases. Thus, this study examined the efficiency and efficacy of different building renovation packages conducted across several buildings in Latvia and in Lithuania (across a larger building stock). In the first section of this study, 13 multi-apartment residential houses with 3 building renovation packages have been investigated in the city of Daugavpils, Latvia, in order to determine the actual reduction in heat energy consumption across each of the renovation implementation packages. The study findings indicate that changes in Latvian building regulations regarding insulation thickness did not significantly impact thermal energy consumption in fully renovated buildings. However, the combination of facade renovations, upgraded heating systems, and improved ventilation systems resulted in substantial energy savings, with an average reduction of 50.59% in thermal energy consumption for space heating across the reviewed multi-apartment residential building stock. In the following section of this study, the impact of the Energy Performance of Buildings Directive (EPBD) on building energy efficiency in Lithuania has been examined. The results show that over a 10-year period in the 2000s, Lithuanian building stock experienced a 20% increase in energy efficiency, followed by an additional 6.3% increase between 2010 and 2016. The mandatory requirement for renovated buildings to achieve a minimum energy efficiency class has resulted in significant reductions in energy consumption for heating purposes. The findings underscore the effectiveness of building renovation packages and the EPBD regulations in enhancing energy efficiency and promoting sustainable building practices. The importance of heat metering, consideration of indoor air temperature, and the need to address indoor air quality during renovations were also highlighted.

20 January 2023 in Sustainability
Verified
Journal Article
Open access
PDF file
EMEdmundas Monstvilas
Edmundas Monstvilas
SBSimon Paul Borg
Simon Paul Borg
Rosita NorvaisieneRosita Norvaisiene
Rosita Norvaisiene
Karolis BanionisKarolis Banionis
Karolis Banionis
JRJuozas Ramanauskas
Juozas Ramanauskas
As per general provisions of European Directive 2010/31/EU on the energy efficiency of buildings (recast), the Lithuanian government transposed the Directive into Lithuanian national law. In the process, the Lithuanian government prepared strategic documents in the field of energy performance and renewable energy that were integrated together through the National Energy and Climate Plan for 2021–2030 (NECP). To better understand the current situation vis-à-vis energy performance, the main characteristics of buildings pertaining to the Lithuanian multi-apartment building stock, classified according to their energy performance class, are analysed and discussed in this paper. Through the exploitation of data from the national Energy Performance Certificate (EPC) register, an overview of the energy performance of the existing Lithuanian residential building stock is presented along with an analysis of the unused potential energy savings pertinent to this building category. The results obtained from the analysed data of energy consumption in buildings shows that the policies adopted over the years were successful in improving the building stock, promoting the move towards the specifications required by a Class A++ (nearly zero energy buildings—NZEB) by 2021. The results show that this was primarily achieved by a significant reduction in the thermal energy used for space heating.

14 August 2022 in Buildings
Verified
Journal Article
Open access
PDF file
RBRaimondas Bliūdžius
Raimondas Bliūdžius
KMKestutis Miskinis
Kestutis Miskinis
VBVincent Buhagiar
Vincent Buhagiar
Karolis BanionisKarolis Banionis
Karolis Banionis
Sound insulation design for structural glazed façade is an important task in environmental noise control, as increased continuously repeated noise is a significant factor impacting on people’s well-being and is associated with a negative impact on their health. For façades, in addition to sound insulation, requirements for safe use and high energy efficiency are also usually raised, which partly determine the composition of the glazing: triple insulating glass unit (IGU) with inner safety laminated glass sheet. Therefore, the aim of the research was to investigate the structural sealed façade structure with triple IGU and to determine the effect of the thickness of ordinary and laminated glasses, their position in the IGU, the thickness of the gas cavities, and the mass of the structural frame on the sound insulation level of structural glazing. Experimental measurements of the sound insulation index of the investigated façade elements with IGU of various constructions were performed in an acoustic reverberation chamber according to standard procedures. The result of the study indicated that the use of the second laminated glass in a triple IGU is inefficient, the highest sound insulation indicators are achieved by increasing the thicknesses of the external glass sheet and the gas cavity; increasing the mass of the frame also has only little effect on the sound insulation of the structural glazing.

9 September 2020 in Energies
Verified
Journal Article
Open access
PDF file
Ainur TukhtamishevaAinur Tukhtamisheva
Ainur Tukhtamisheva
DADinarr Adilova
Dinarr Adilova
Karolis BanionisKarolis Banionis
Karolis Banionis
ASAurelija Stonkuvienė
Aurelija Stonkuvienė
RBRaimondas Bliūdžius
Raimondas Bliūdžius
Kazakhstan is country rich in energy resources, but to raise the living standards of the country’s population, the government regulates prices of heating energy, which are significantly lower comparing to those in the global energy market. Such an approach encourages the construction of residential buildings without concern for their energy efficiency, which significantly increases energy consumption in the sector and leads to the increase of greenhouse gas emissions into the environment. Therefore, the aim of this study was to analyze the impact of regulated low prices of heating energy on long-term energy use in buildings, to determine optimal levels of building thermal insulation at current energy prices and following global energy price trends, and to demonstrate the impact of more efficient building thermal insulation on heating energy consumption from a long-time perspective. The cost-optimal method used in EU countries was chosen for the optimization of building thermal insulation and energy consumption to compare the impact of energy prices on the optimal thermal insulation of buildings. The results of the study showed that maintaining low energy prices hinders the implementation of energy-efficient solutions in buildings and does not provide an economic justification for prolonging the heating season by ensuring the quality of the indoor microclimate. As a practical result of this study, a recommendation was made to introduce optimal thermal insulation requirements in building regulations and to redistribute part of the energy subsidies for implementation of energy-efficient measures in the residential building sector.