Mimicking the morphological structure of native blood vessels is critical for the development of vascular grafts. Herein, small-diameter composite vascular grafts that integrate the nanofibrous bacterial cellulose (BC) and submicrofibrous cellulose acetate (CA) were fabricated via a combined electrospinning and step-by-step in situ biosynthesis. Scanning electron microscopy (SEM) observation shows the nano/submicro-fibrous morphology and well-interconnected porous structure of the BC/CA grafts. It is found that the BC/CA graft with a suitable BC content demonstrates lower potential of thrombus formation and enhanced endothelialization as compared to the BC and CA counterparts. Western blotting and RT-qPCR results suggest that the BC/CA-2 graft promotes endothelialization by improving expressions of genes vWF-1 and CD31 and protein CD31. The in vivo tests demonstrate much lower inflammatory response to the BC/CA graft. These results suggest that the BC/CA graft shows a great potential as an artificial graft for rapid formation of an endothelial cell monolayer.
The ventricular assist pumps do not always function at the design point; instead, these pumps may operate at unfavorable off-design points. For example, the axial ventricular assist pump FW-2, in which the design point is 5 L/min flow rate against 100 mm Hg pressure increase at 8,000 rpm, sometimes works at off-design flow rates of 1 to 4 L/min. The hemolytic performance of the FW-2 at both the design point and at off-design points was estimated numerically and tested in vitro. Flow characteristics in the pump were numerically simulated and analyzed with special attention paid to the scalar sheer stress and exposure time. An in vitro hemolysis test was conducted to verify the numerical results. The simulation results showed that the scalar shear stress in the rotor region at the 1 L/min off-design point was 70% greater than at the 5 L/min design point. The hemolysis index at the 1 L/min off-design point was 3.6 times greater than at the 5 L/min design point. The in vitro results showed that the normalized index of hemolysis increased from 0.017 g/100 L at the 5 L/min design point to 0.162 g/100 L at the 1 L/min off-design point. The hemolysis comparison between the different blood pump flow rates will be helpful for future pump design point selection and will guide the usage of ventricular assist pumps. The hemolytic performance of the blood pump at the working point in the clinic should receive more focus.
1 January 2012 in International Journal of Chemical Engineering
The tip structure of LVAD inflow cannula is one of major factors to lead adverse events such as thrombosis and suction leading to obstruction. In this research, four kinds of tips that had been used in inflow cannulas were selected and designed. The flow field of the four inflow cannulas inserted into the apex of left ventricle (LV) was numerically computed by computational fluid dynamics. The flow behavior was analyzed in order to compare the blood compatibility and suction in left ventricle and cannulas after the inflow cannulas with different tips were inserted to the apex of LV. The results showed that the cannula tip structure affected the LVAD performance. Among these four cannulas, the trumpet-tipped inflow cannula owned the best performance in smooth flow velocity distribution without backflow or low-velocity flow so that it was the best in blood compatibility. Nevertheless, the caged tipped cannula was the worst in blood compatibility. And the blunt-tipped and beveled tipped inflow cannulas may obstruct more easily than trumpet and caged tipped inflow cannulas because of their shape. The study indicated that the trumpet tip was the most preferable for the inflow cannula of long-term LVAD.
Bioprosthetic heart valves derived from glutaraldehyde (Glut)-fixed xenografts have been widely used to replace diseased cardiac valves. However, calcification and degeneration are common following their implantation. Inflammation is closely associated with calcification of Glut-fixed xenografts via macrophage infiltration. Tannic acid (TA) possesses anti-inflammatory effects. This study was designed to investigate the anti-calcification of TA treatment on the Glut-fixed bovine pericardium (BP) in a rat subdermal model. Fresh BP was divided into two groups (10 in each group) and separately subjected to different fixation procedures as follows: (1) Glut group: fixation with 0.6% Glut alone; (2) Glut/TA group: fixation with 0.6% Glut and subsequent 0.3% TA. Then the BP samples were subdermally implanted in juvenile male Sprague-Dawley rats and explanted 21 days after implantation. Each explanted BP sample was divided into three parts for calcium content analysis, von Kossa's staining and immunohistochemical staining, and reverse transcription-polymerase chain reaction study. The data from quantitative calcium analysis and von Kossa's staining showed that Glut-fixed BP developed significantly more calcification than Glut/TA-fixed BP ((90.3±32.5) mg/g dry weight vs (6.4±1.3) mg/g dry tissue, P < 0.01). Immunostaining demonstrated lower matrix metalloproteinase-9 and tenascin-C expression as well as macrophage infiltration into Glut/TA-fixed BP than in its Glut-fixed counterpart (P <0.01 for all). Additionally, the reverse transcription-polymerase chain reaction study showed that higher levels of expression of matrix metalloproteinase-9 and tenascin-C mRNA occurred within Glut-fixed BP than within the Glut/TA-fixed ones (P <0.01 for all). TA exerts excellent anti-calcification effects on Glut-fixed BP via inhibiting macrophage infiltration and expression of matrix metalloproteinase-9 and tenascin-C.
8 February 2017 in The International Journal of Artificial Organs
A fully implantable axial left ventricular assist device LAP31 was developed for Chinese or other heart failure patients who need partial support. Based on the 5-Lpm total cardiac blood output of Chinese without heart failure disease, the design point of LAP31 was set to a flow rate of 3 Lpm with 100-mmHg pressure head. To achieve the required pressure head and good hemolytic performance, a structure that includes a spindly rotor hub and a diffuser with splitter and cantilevered main blades was developed. Computational fluid dynamics (CFD) was used to analyze the hydraulic and hemodynamic performance of LAP31. Then in vitro hydraulics experiments were conducted. The numerical simulation results show that LAP31 could generate a 1 to 8 Lpm flow rate with a 60.9 to 182.7 mmHg pressure head when the pump was rotating between 9,000 and 12,000 rpm. The average scalar shear stress of the blood pump was 21.7 Pa, and the average exposure time was 71.0 milliseconds. The mean hemolysis index of LAP31 obtained using Heuser's hemolysis model and Giersiepen's model was 0.220% and 3.89 × 105% respectively. After adding the splitter blades, the flow separation at the suction surface of the diffuser was reduced. The cantilever structure reduced the tangential velocity from 6.1 to 4.7–1.4 m/s within the blade gap by changing the blade gap from shroud to hub. Subsequently, the blood damage caused by shear stress was reduced. In conclusion, the hydraulic and hemolytic characteristics of the LAP31 are acceptable for partial support.