Miriam. G. E. Oldhoff

Miriam. G. E. Oldhoff

Auto-generated profile, based on publicly available information

Miriam. G. E. Oldhoff

Department of Trauma Surgery, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 June 2023 in European Journal of Trauma and Emergency Surgery
Verified
Journal Article
Open access
PDF file
NANick Assink
Nick Assink
MOMiriam G. E. Oldhoff
Miriam G. E. Oldhoff
KDKaj ten Duis
Kaj ten Duis
Joep KraeimaJoep Kraeima
Joep Kraeima
JDJob N. Doornberg
Job N. Doornberg
FIFrank IJpma
Frank IJpma
Purpose: A substantial proportion of conventional tibial plateau plates have a poor fit, which may result in suboptimal fracture reduction due to applied -uncontrolled- compression on the bone. This study aimed to assess whether patient-specific osteosyntheses could facilitate proper fracture reduction in medial tibial plateau fractures. Methods: In three Thiel embalmed human cadavers, a total of six tibial plateau fractures (three Schatzker 4, and three Schatzker 6) were created and CT scans were made. A 3D surgical plan was created and a patient-specific implant was designed and fabricated for each fracture. Drilling guides that fitted on top of the customized plates were designed and 3D printed in order to assist the surgeon in positioning the plate and steering the screws in the preplanned direction. After surgery, a postoperative CT scan was obtained and outcome was compared with the preoperative planning in terms of articular reduction, plate positioning, and screw direction. Results: A total of six patient-specific implants including 41 screws were used to operate six tibial plateau fractures. Three fractures were treated with single plating, and three fractures with dual plating. The median intra-articular gap was reduced from 6.0 (IQR 4.5–9.5) to 0.9 mm (IQR 0.2–1.4), whereas the median step-off was reduced from 4.8 (IQR 4.1–5.3) to 1.3 mm (IQR 0.9–1.5). The median Euclidean distance between the centre of gravity of the planned and actual implant was 3.0 mm (IQR: 2.8–3.7). The lengths of the screws were according to the predetermined plan. None of the screws led to screw penetration. The median difference between the planned and actual screw direction was 3.3° (IQR: 2.5–5.1). Conclusion: This feasibility study described the development and implementation of a patient-specific workflow for medial tibial plateau fracture surgery that facilitates proper fracture reduction, tibial alignment and accurately placed screws by using custom-made osteosynthesis plates with drilling guides.

23 January 2024 in European Journal of Trauma and Emergency Surgery
Verified
Journal Article
Open access
PDF file
MOMiriam G. E. Oldhoff
Miriam G. E. Oldhoff
NANick Assink
Nick Assink
Joep KraeimaJoep Kraeima
Joep Kraeima
Jean-Paul P.M. De VriesJean-Paul P.M. De Vries
Jean-Paul P.M. De Vries
KDKaj ten Duis
Kaj ten Duis
FIFrank IJpma
Frank IJpma
Purpose: There is a debate whether corrective osteotomies of the distal radius should be performed using a 3D work-up with pre-contoured conventional implants (i.e., of-the-shelf) or patient-specific implants (i.e., custom-made). This study aims to assess the postoperative accuracy of 3D-assisted correction osteotomy of the distal radius using either implant. Methods: Twenty corrective osteotomies of the distal radius were planned using 3D technologies and performed on Thiel embalmed human cadavers. Our workflow consisted of virtual surgical planning and 3D printed guides for osteotomy and repositioning. Subsequently, left radii were fixated with patient-specific implants, and right radii were fixated with pre-contoured conventional implants. The accuracy of the corrections was assessed through measurement of rotation, dorsal and radial angulation and translations with postoperative CT scans in comparison to their preoperative virtual plan. Results: Twenty corrective osteotomies were executed according to their plan. The median differences between the preoperative plan and postoperative results were 2.6° (IQR: 1.6–3.9°) for rotation, 1.4° (IQR: 0.6–2.9°) for dorsal angulation, 4.7° (IQR: 2.9–5.7°) for radial angulation, and 2.4 mm (IQR: 1.3–2.9 mm) for translation of the distal radius, thus sufficient for application in clinical practice. There was no significant difference in accuracy of correction when comparing pre-contoured conventional implants with patient-specific implants. Conclusion: 3D-assisted corrective osteotomy of the distal radius with either pre-contoured conventional implants or patient-specific implants results in accurate corrections. The choice of implant type should not solely depend on accuracy of the correction, but also be based on other considerations like the availability of resources and the preoperative assessment of implant fitting.

6 September 2022 in Journal of Personalized Medicine
Verified
Journal Article
Open access
PDF file
AMAnne Meesters
Anne Meesters
MOMiriam G. E. Oldhoff
Miriam G. E. Oldhoff
NTNeeltje Margaretha Trouwborst
Neeltje Margaretha Trouwborst
NANick Assink
Nick Assink
Joep KraeimaJoep Kraeima
Joep Kraeima
FIFrank IJpma
Frank IJpma
This study aims to develop a three-dimensional (3D) measurement for acetabular fracture displacement, determine the inter- and intra-observer variability, and correlate the measurement with clinical outcome. Three-dimensional models were created for 100 patients surgically treated for acetabular fractures. The ‘3D gap area’, the 3D surface between all the fracture fragments, was developed. The association between the 3D gap area and the risk of conversion to a total hip arthroplasty (THA) was determined by an ROC curve and a Cox regression analysis. The 3D gap area had an excellent inter-observer and intra-observer reliability. The preoperative median 3D gap area for patients without and with a THA was 1731 mm2 versus 2237 mm2. The median postoperative 3D gap area was 640 mm2 versus 845 mm2. The area under the curve was 0.63. The Cox regression analysis showed that a preoperative 3D gap area > 2103 mm2 and a postoperative 3D gap area > 1058 mm2 were independently associated with a 3.0 versus 2.4 times higher risk of conversion to a THA. A 3D assessment of acetabular fractures is feasible, reproducible, and correlates with clinical outcome. Three-dimensional measurements could be added to the current classification systems to quantify the level of fracture displacement and to assess operative results.

24 January 2025 in European Journal of Trauma and Emergency Surgery
Verified
Journal Article
Open access
PDF file
MOM. G. E. Oldhoff
M. G. E. Oldhoff
CAC. Posada Alvarez
C. Posada Alvarez
KDKaj ten Duis
Kaj ten Duis
JDJ. N. Doornberg
J. N. Doornberg
NANick Assink
Nick Assink
FIFrank IJpma
Frank IJpma
Purpose: The aim of this study was to evaluate the feasibility of using patient-specific implants (PSI) for complex shaft corrective osteotomies in multiplanar deformities of long bones in the lower extremities. Additionally, it aimed to investigate the added value of these implants by quantifying surgical accuracy on postoperative CT, comparing their outcomes to two commonly used techniques: 3D virtual visualizations and 3D-printed surgical guides. Methods: Six tibial and femoral shaft corrective osteotomies were planned and performed on three Thiel embalmed human specimen. Depending on the specimen a different respective technique was used; 1) ‘3D Visualization’ using 3D virtual plan preoperatively and free-hand corrective osteotomy techniques with standard manually contoured plates; 2) ‘3D guided’ utilizing 3D surgical guides and manually contouring of conventional implant; and 3) ‘ 3D PSI’ utilizing a 3D surgical guide with a patient-specific implant. Accuracy of the corrections was assessed through measurements for varus/valgus angulation, ante/recurvation, rotation and osteotomy plane error as quantified on postoperative CT-scans. Results: Twelve corrective osteotomies were performed. For, the median difference between the surgical plan and postoperative CT assessment was 3.4°, 4.6°, and 2.2° for the ‘3D visualization’, ‘3D guided’, and ‘3D PSI’ methods respectively. Regarding ante/recurvation, the differences were 3.8°, 43.8°, and 1.2°, respectively. For rotation, the differences were 11.9°, 18.7°, and 3.5°, respectively. Discrepancies between planned and executed levels of osteotomy plane were 6.2 mm, 3.2 mm, and 1.4 mm, respectively. Conclusion: PSIs with 3D-printed drilling guides for complex multiplanar corrective osteotomies of femoral and tibial shaft malunions is feasible and achieves accurate corrections. This technique enables precise determination of the osteotomy plane, guides correction in all three planes, and ensures satisfactory implant fitting; thus accurately translating the virtual surgical plan into clinical practice. The 3D PSI method is beneficial for complex cases with significant multiplanar deformities in bone anatomy, particularly with rotational malalignment.

5 September 2024 in Journal of Orthopaedic Surgery and Research
Verified
Journal Article
Open access
PDF file
MOM. G. E. Oldhoff
M. G. E. Oldhoff
ZKZ. Kamal
Z. Kamal
KDK. Ten Duis
K. Ten Duis
FWF. W. Wubs
F. W. Wubs
JVJ. P. P. M. de Vries
J. P. P. M. de Vries
FIF. F. A. Ijpma
F. F. A. Ijpma
In acetabular fracture surgery, understanding the biomechanical behaviour of fractures and implants is beneficial for clinical decision-making about implant selection and postoperative (early) weightbearing protocols. This study outlines a novel approach for creating finite element models (FEA) from actual clinical cases. Our objectives were to (1) create a detailed semi-automatic three-dimensional FEA of a patient with a transverse posterior wall acetabular fracture and (2) biomechanically compare patient-specific implants with manually bent off-the-shelf implants. A computational study was performed in which we developed three finite element models. The models were derived from clinical imaging data of a 20-year-old male with a transverse posterior wall acetabular fracture treated with a patient-specific implant. This implant was designed to fit the patient's anatomy and fracture configuration, allowing for optimal placement and predetermined screw trajectories. The three FEA models included an intact hemipelvis for baseline comparison, one with a fracture fixated with a patient-specific implant, and another with a conventional implant. Two loading conditions were investigated: standing up and peak walking forces. Von Mises stress and displacement patterns in bone, implants and screws were analysed to assess the biomechanical behaviour of fracture fixation with either a patient-specific versus a conventional implant. The finite element models demonstrated that for a transverse posterior wall type fracture, a patient-specific implant resulted in lower peak stresses in the bone (30 MPa and 56 MPa) in standing-up and peak walking scenario, respectively, compared to the conventional implant model (46 MPa and 90 MPa). The results suggested that patient-specific implant could safely withstand standing-up and walking after surgery, with maximum von Mises stresses in the implant of 156 MPa and 371 MPa, respectively. The results from the conventional implant indicate a likelihood of implant failure, with von Mises stresses in the implant (499 MPa and 1000 MPa) exceeding the yield stress of stainless steel. This study presents a workflow for conducting finite element analysis of real clinical cases in acetabular fracture surgery. This concept of personalized biomechanical fracture and implant assessment can eventually be applied in clinical settings to guide implant selection, compare conventional implants with innovative patient-specific ones, optimizing implant designs (including shape, size, materials, screw positions), and determine whether immediate full weight-bearing can be safely permitted.

1 February 2025 in The Bone & Joint Journal
Verified
Journal Article
Closed access
PDF file
NTNeeltje M. Trouwborst
Neeltje M. Trouwborst
MOMiriam. G. E. Oldhoff
Miriam. G. E. Oldhoff
KDKaj ten Duis
Kaj ten Duis
SHSven H. van Helden
Sven H. van Helden
EHErik Hermans
Erik Hermans
FIFrank IJpma
Frank IJpma
Aims: The aim of the study was to apply 3D measurements for fracture displacement in minimally to moderately displaced acetabular fractures treated nonoperatively, and to evaluate whether this measurement can be used to estimate the likelihood of conversion to total hip arthroplasty (THA) at follow-up.Methods: A multicentre, cross-sectional study was performed on 144 patients who were treated nonoperatively for an acetabular fracture in four level 1 trauma centres between January 2000 and December 2020. For each patient, fracture displacement was measured on CT-based 3D models. The 3D gap area represents fracture displacement (mm2) between all fracture fragments. A receiver operating characteristic curve was generated to determine a 3D gap area threshold representing the optimal sensitivity and specificity to predict conversion to THA. Native hip survival was reported using Kaplan-Meier curves. Predictors of conversion to THA were determined using Cox regression analysis.Results: Of 144 patients, 18 (12%) received a THA. The median 3D gap area of the complete study cohort was 692 mm2 (IQR 216 to 1,400). Native hip survival in patients with a gap area threshold ≤ 1,171 or > 1,171 mm2 differed at one-year (98% vs 85%), two-year (96% vs 77%), and five-year follow-up (92% vs 73%). 3D gap area > 1,171 mm2 (hazard ratio (HR) 4.3; 95% CI 1.7 to 11.0) and the presence of osteoarthritis grade 2 or higher (HR 3.1; 95% CI 1.2 to 7.8) independently predicted the likelihood of conversion to THA during follow-up.Conclusion: For nonoperatively treated acetabular fractures, introducing 3D gap area assessment to measure fracture displacement offers a promising approach for assessing the risk of conversion to THA. With the introduction of (semi-)automatic segmentation and measurement techniques, or their implementation into commercially available software, this 3D gap area measurement can serve as an addition to the Letournel classification and an alternative to traditional 2D gap and step-off measurements, improving accuracy, reproducibility, and applicability in clinical decision-making.Cite this article: Bone Joint J 2025;107-B(2):204–212.