Andreas Meiser

Dr. Andreas Meiser

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2021 in The Lancet Respiratory Medicine
Verified
Journal Article
Closed access
AMAndreas Meiser
Andreas Meiser
TVThomas Volk
Thomas Volk
JWJan Wallenborn
Jan Wallenborn
UGUlf Guenther
Ulf Guenther
TBTobias Becher
Tobias Becher
RWRichard Wetzold
Richard Wetzold

1 June 2012 in Transplant Infectious Disease
Verified
Journal Article
Closed access
PDF file
PJP. Jeanmonod
P. Jeanmonod
MHM. Hubbuch
M. Hubbuch
FGF. Grünhage
F. Grünhage
AMAndreas Meiser
Andreas Meiser
KRK. Rass
K. Rass
OKO. Kollmar
O. Kollmar

22 October 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
Tizian JahreisTizian Jahreis
Tizian Jahreis
JKJessica Kretschmann
Jessica Kretschmann
NWNick Weidner
Nick Weidner
TVThomas Volk
Thomas Volk
AMAndreas Meiser
Andreas Meiser
Heinrich Volker GroesdonkHeinrich Volker Groesdonk
Heinrich Volker Groesdonk
Background: To assess the risk of aspiration, nutrient tolerance, and gastric emptying of patients in ICUs, gastric ultrasound can provide information about the gastric contents. Using established formulas, the gastric residual volume (GRV) can be calculated in a standardized way by measuring the gastric antrum. The purpose of this study was to determine the GRV in a cohort of enterally fed patients using a miniaturized ultrasound device to achieve knowledge about feasibility and the GRV over time during the ICU stay. The findings could contribute to the optimization of enteral nutrition (EN) therapy. Methods: A total of 217 ultrasound examinations with 3 measurements each (651 measurements in total) were performed twice daily (morning and evening) in a longitudinal observational study on 18 patients with EN in the interdisciplinary surgical ICU of Saarland University Medical Center. The measured values of the GRV were analyzed in relation to the clinical course, the nutrition, and other parameters. Results: Measurements could be performed without interrupting the flow of clinical care and without pausing EN. The GRV was significantly larger with sparsely auscultated bowel sounds than with normal and excited bowel sounds (p < 0.01). Furthermore, a significantly larger GRV was present when using a high-caloric/low-protein nutritional product compared to an isocaloric product (p = 0.02). The GRV at the morning and evening measurements showed no circadian rhythm. When comparing the first and last ultrasound examination of each patient, there was a tendency towards an increased GRV (p = 0.07). Conclusion: The GRV measured by miniaturized ultrasound devices can provide important information about ICU patients without restricting treatment procedures in the ICU. Measurements are possible while EN therapy is ongoing. Further studies are needed to establish gastric ultrasound as a management tool in nutrition therapy.

1 September 2024 in Critical Care
Verified
Journal Article
Open access
PDF file
LMLukas M. Müller-Wirtz
Lukas M. Müller-Wirtz
BOBrian O’gAra
Brian O’gAra
MAMarcelo Gama de Abreu
Marcelo Gama de Abreu
MSMarcus J. Schultz
Marcus J. Schultz
JBJeremy R. Beitler
Jeremy R. Beitler
AMAndreas Meiser
Andreas Meiser
This review explores the complex interactions between sedation and invasive ventilation and examines the potential of volatile anesthetics for lung- and diaphragm-protective sedation. In the early stages of invasive ventilation, many critically ill patients experience insufficient respiratory drive and effort, leading to compromised diaphragm function. Compared with common intravenous agents, inhaled sedation with volatile anesthetics better preserves respiratory drive, potentially helping to maintain diaphragm function during prolonged periods of invasive ventilation. In turn, higher concentrations of volatile anesthetics reduce the size of spontaneously generated tidal volumes, potentially reducing lung stress and strain and with that the risk of self-inflicted lung injury. Taken together, inhaled sedation may allow titration of respiratory drive to maintain inspiratory efforts within lung- and diaphragm-protective ranges. Particularly in patients who are expected to require prolonged invasive ventilation, in whom the restoration of adequate but safe inspiratory effort is crucial for successful weaning, inhaled sedation represents an attractive option for lung- and diaphragm-protective sedation. A technical limitation is ventilatory dead space introduced by volatile anesthetic reflectors, although this impact is minimal and comparable to ventilation with heat and moisture exchangers. Further studies are imperative for a comprehensive understanding of the specific effects of inhaled sedation on respiratory drive and effort and, ultimately, how this translates into patient-centered outcomes in critically ill patients. Graphical abstract

22 August 2017 in BMC Pulmonary Medicine
Verified
Journal Article
Open access
PDF file
THTobias Hüppe
Tobias Hüppe
DLDominik Lorenz
Dominik Lorenz
MWMario Wachowiak
Mario Wachowiak
FMFelix Maurer
Felix Maurer
AMAndreas Meiser
Andreas Meiser
SKSascha Kreuer
Sascha Kreuer
Expired gas (exhalome) analysis of ventilated critical ill patients can be used for drug monitoring and biomarker diagnostics. However, it remains unclear to what extent volatile organic compounds are present in gases from intensive care ventilators, gas cylinders, central hospital gas supplies, and ambient air. We therefore systematically evaluated background volatiles in inspired gas and their influence on the exhalome. We used multi-capillary column ion-mobility spectrometry (MCC-IMS) breath analysis in five mechanically ventilated critical care patients, each over a period of 12 h. We also evaluated volatile organic compounds in inspired gas provided by intensive care ventilators, in compressed air and oxygen from the central gas supply and cylinders, and in the ambient air of an intensive care unit. Volatiles detectable in both inspired and exhaled gas with patient-to-inspired gas ratios < 5 were defined as contaminating compounds. A total of 76 unique MCC-IMS signals were detected, with 39 being identified volatile compounds: 73 signals were from the exhalome, 12 were identified in inspired gas from critical care ventilators, and 34 were from ambient air. Five volatile compounds were identified from the central gas supply, four from compressed air, and 17 from compressed oxygen. We observed seven contaminating volatiles with patient-to-inspired gas ratios < 5, thus representing exogenous signals of sufficient magnitude that might potentially be mistaken for exhaled biomarkers. Volatile organic compounds can be present in gas from central hospital supplies, compressed gas tanks, and ventilators. Accurate assessment of the exhalome in critical care patients thus requires frequent profiling of inspired gases and appropriate normalisation of the expired signals.

6 December 2021 in Acta Anaesthesiologica Scandinavica
Verified
Journal Article
Open access
PDF file
Lukas Martin Müller-WirtzLukas Martin Müller-Wirtz
Lukas Martin Müller-Wirtz
FBFlorian Behne
Florian Behne
AKAzzeddine Kermad
Azzeddine Kermad
GWGudrun Wagenpfeil
Gudrun Wagenpfeil
MSMatthias Schroeder
Matthias Schroeder
AMAndreas Meiser
Andreas Meiser
Background: Spontaneous breathing is desirable in most ventilated patients. We therefore studied the influence of isoflurane versus propofol sedation on early spontaneous breathing in ventilated surgical intensive care patients and evaluated potential mediation by opioids and arterial carbon dioxide during the first 20 h of study sedation.Methods: We included a single‐center subgroup of 66 patients, who participated in a large multi‐center trial assessing efficacy and safety of isoflurane sedation, with 33 patients each randomized to isoflurane or propofol sedation. Both sedatives were titrated to a sedation depth of −4 to −1 on the Richmond Agitation Sedation Scale. The primary outcome was the fraction of time during which patients breathed spontaneously.Results: Baseline characteristics of isoflurane and propofol‐sedated patients were well balanced. There were no substantive differences in management or treatment aside from sedation, and isoflurane and propofol provided nearly identical sedation depths. The mean fraction of time spent spontaneously breathing was 82% [95% CI: 69, 90] in patients sedated with isoflurane compared to 35% [95% CI: 22, 51] in those assigned to propofol: median difference: 61% [95% CI: 14, 89], p < .001. After adjustments for sufentanil dose and arterial carbon dioxide partial pressure, patients sedated with isoflurane were twice as likely to breathe spontaneously than those sedated with propofol: adjusted risk ratio: 2.2 [95%CI: 1.4, 3.3], p < .001.Conclusions: Isoflurane compared to propofol sedation promotes early spontaneous breathing in deeply sedated ventilated intensive care patients. The benefit appears to be a direct effect isoflurane rather than being mediated by opioids or arterial carbon dioxide.