Tobias Hüppe

Tobias Hüppe

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 May 2021 in Molecules
Verified
Journal Article
Open access
PDF file
Lukas Martin Müller-WirtzLukas Martin Müller-Wirtz
Lukas Martin Müller-Wirtz
DKDaniel Kiefer
Daniel Kiefer
SRSven Ruffing
Sven Ruffing
TBTimo Brausch
Timo Brausch
THTobias Hüppe
Tobias Hüppe
FMFelix Maurer
Felix Maurer
Exhaled aliphatic aldehydes were proposed as non-invasive biomarkers to detect increased lipid peroxidation in various diseases. As a prelude to clinical application of the multicapillary column–ion mobility spectrometry for the evaluation of aldehyde exhalation, we, therefore: (1) identified the most abundant volatile aliphatic aldehydes originating from in vitro oxidation of various polyunsaturated fatty acids; (2) evaluated emittance of aldehydes from plastic parts of the breathing circuit; (3) conducted a pilot study for in vivo quantification of exhaled aldehydes in mechanically ventilated patients. Pentanal, hexanal, heptanal, and nonanal were quantifiable in the headspace of oxidizing polyunsaturated fatty acids, with pentanal and hexanal predominating. Plastic parts of the breathing circuit emitted hexanal, octanal, nonanal, and decanal, whereby nonanal and decanal were ubiquitous and pentanal or heptanal not being detected. Only pentanal was quantifiable in breath of mechanically ventilated surgical patients with a mean exhaled concentration of 13 ± 5 ppb. An explorative analysis suggested that pentanal exhalation is associated with mechanical power—a measure for the invasiveness of mechanical ventilation. In conclusion, exhaled pentanal is a promising non-invasive biomarker for lipid peroxidation inducing pathologies, and should be evaluated in future clinical studies, particularly for detection of lung injury.

22 August 2017 in BMC Pulmonary Medicine
Verified
Journal Article
Open access
PDF file
THTobias Hüppe
Tobias Hüppe
DLDominik Lorenz
Dominik Lorenz
MWMario Wachowiak
Mario Wachowiak
FMFelix Maurer
Felix Maurer
AMAndreas Meiser
Andreas Meiser
SKSascha Kreuer
Sascha Kreuer
Expired gas (exhalome) analysis of ventilated critical ill patients can be used for drug monitoring and biomarker diagnostics. However, it remains unclear to what extent volatile organic compounds are present in gases from intensive care ventilators, gas cylinders, central hospital gas supplies, and ambient air. We therefore systematically evaluated background volatiles in inspired gas and their influence on the exhalome. We used multi-capillary column ion-mobility spectrometry (MCC-IMS) breath analysis in five mechanically ventilated critical care patients, each over a period of 12 h. We also evaluated volatile organic compounds in inspired gas provided by intensive care ventilators, in compressed air and oxygen from the central gas supply and cylinders, and in the ambient air of an intensive care unit. Volatiles detectable in both inspired and exhaled gas with patient-to-inspired gas ratios < 5 were defined as contaminating compounds. A total of 76 unique MCC-IMS signals were detected, with 39 being identified volatile compounds: 73 signals were from the exhalome, 12 were identified in inspired gas from critical care ventilators, and 34 were from ambient air. Five volatile compounds were identified from the central gas supply, four from compressed air, and 17 from compressed oxygen. We observed seven contaminating volatiles with patient-to-inspired gas ratios < 5, thus representing exogenous signals of sufficient magnitude that might potentially be mistaken for exhaled biomarkers. Volatile organic compounds can be present in gas from central hospital supplies, compressed gas tanks, and ventilators. Accurate assessment of the exhalome in critical care patients thus requires frequent profiling of inspired gases and appropriate normalisation of the expired signals.

1 March 2016 in Journal of Breath Research
Verified
Journal Article
Closed access
PDF file
THTobias Hüppe
Tobias Hüppe
DLDominik Lorenz
Dominik Lorenz
FMFelix Maurer
Felix Maurer
FAFrederic W Albrecht
Frederic W Albrecht
KSKristina Schnauber
Kristina Schnauber
SKSascha Kreuer
Sascha Kreuer
Ischemia and reperfusion alter metabolism. Multi-capillary column ion-mobility spectrometry (MCC-IMS) can identify volatile organic compounds (VOCs) in exhaled gas. We therefore used MCC-IMS to evaluate exhaled gas in a rat model of hemorrhagic shock with reperfusion. Adult male Sprague-Dawley rats ( n = 10 in control group, n = 15 in intervention group) were anaesthetized and ventilated via tracheostomy for 14 h or until death. Hemorrhagic shock was maintained for 90 min by removing blood from the femoral artery to a target of MAP 35 ± 5 mmHg, and then retransfusing the blood over 60 min in 15 rats; 10 control rats were evaluated without shock and reperfusion. Exhaled gas was analyzed with MCC-IMS, VOCs were identified using the BS-MCC/IMS analytes database (Version 1209). VOC intensities were analyzed at the end of shock, end of reperfusion, and after 9 h. All normotensive animals survived the observation period, whereas mean survival time was 11.2 h in shock and reperfusion animals. 16 VOCs differed significantly for at least one of the three analysis periods. Peak intensities of butanone, 2-ethyl-1-hexanol, nonanal, and an unknown compound were higher in shocked than normotensive rats, and another unknown compound increased over the time. 1-butanol increased only during reperfusion. Acetone, butanal, 1.2-butandiol, isoprene, 3-methylbutanal, 3-pentanone, 2-propanol, and two unknown compounds were lower and decreased during shock and reperfusion. 1-pentanol and 1-propanol were significant greater in the hypotensive animals during shock, were comparable during reperfusion, and then decreased after resuscitation. VOCs differ during hemorrhagic shock, reperfusion, and after reperfusion. MCC-IMS of exhaled breath deserves additional study as a non-invasive approach for monitoring changes in metabolism during ischemia and reperfusion.

20 August 2014 in Der Anaesthesist
Verified
Journal Article
Closed access
PDF file
SLS. Löser
S. Löser
AHAnna Herminghaus
Anna Herminghaus
THTobias Hüppe
Tobias Hüppe
WWW. Wilhelm
W. Wilhelm

15 June 2020 in Metabolites
Verified
Journal Article
Open access
PDF file
FAFrederic W. Albrecht
Frederic W. Albrecht
FMFelix Maurer
Felix Maurer
Lukas Martin Müller-WirtzLukas Martin Müller-Wirtz
Lukas Martin Müller-Wirtz
MSMichaela H. Schwaiblmair
Michaela H. Schwaiblmair
THTobias Hüppe
Tobias Hüppe
TFTobias Fink
Tobias Fink
Systemic inflammation alters the composition of exhaled breath, possibly helping clinicians diagnose conditions such as sepsis. We therefore evaluated changes in exhaled breath of rats given tumor necrosis factor-alpha (TNF-α). Thirty male Sprague-Dawley rats were randomly assigned to three groups (n = 10 each) with intravenous injections of normal saline (control), 200 µg·kg−1 bodyweight TNF-α (TNF-α-200), or 600 µg·kg−1 bodyweight TNF-α (TNF-α-600), and were observed for 24 h or until death. Animals were ventilated with highly-purified synthetic air to analyze exhaled air by multicapillary column–ion mobility spectrometry. Volatile organic compounds (VOCs) were identified from a database. We recorded blood pressure and cardiac output, along with cytokine plasma concentrations. Control rats survived the 24 h observation period, whereas mean survival time decreased to 22 h for TNF-α-200 and 23 h for TNF-α-600 rats. Mean arterial pressure decreased in TNF-α groups, whereas IL-6 increased, consistent with mild to moderate inflammation. Hundreds of VOCs were detected in exhalome. P-cymol increased by a factor-of-two 4 h after injection of TNF-α-600 compared to the control and TNF-α-200. We found that 1-butanol and 1-pentanol increased in both TNF-α groups after 20 h compared to the control. As breath analysis distinguishes between two doses of TNF-α and none, we conclude that it might help clinicians identify systemic inflammation.

22 October 2019 in BMC Medical Education
Verified
Journal Article
Open access
PDF file
THTobias Hüppe
Tobias Hüppe
HGHeinrich Volker Groesdonk
Heinrich Volker Groesdonk
TVThomas Volk
Thomas Volk
SWStefan Wagenpfeil
Stefan Wagenpfeil
BWBenedict Wallrich
Benedict Wallrich
Background: Transthoracic echocardiography is the primary imaging modality for diagnosing cardiac conditions but medical education in this field is limited. We tested the hypothesis that a structured theoretical and supervised practical course of training in focused echocardiography in last year medical students results in a more accurate assessment and more precise calculation of left ventricular ejection fraction after ten patient examinations. Methods: After a theoretical introduction course 25 last year medical students performed ten transthoracic echocardiographic examination blocks in postsurgical patients. Left ventricular function was evaluated both with an eye-balling method and with the calculated ejection fraction using diameter and area of left ventricles. Each examination block was controlled by a certified and blinded tutor. Bias and precision of measurements were assessed with Bland and Altman method. Results: Using the eye-balling method students agreed with the tutor’s findings both at the beginning (88%) but more at the end of the course (95.7%). The variation between student and tutor for calculation of area, diameter and ejection fraction, respectively, was significantly lower in examination block 10 than in examination block 1 (each p < 0.001). Students underestimated both the length and the area of the left ventricle at the outset, as complete imaging of the left heart in the ultrasound sector was initially unsuccessful. Conclusions: A structured theoretical and practical transthoracic echocardiography course of training for last year medical students provides a clear and measurable learning experience in assessing and measuring left ventricular function. At least 14 examination blocks are necessary to achieve 90% agreement of correct determination of the ejection fraction.