Kar-Hooi Cheong

Dr. Kar-Hooi Cheong

orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 June 2004 in Experiments in Fluids
Verified
Journal Article
Closed access
PDF file
CIC. Iwaki
C. Iwaki
KCKar-Hooi Cheong
Kar-Hooi Cheong
HMH. Monji
H. Monji
GMG. Matsui
G. Matsui

1 August 2016 in Flow Measurement and Instrumentation
Verified
Journal Article
Closed access
RDRyouji Doihara
Ryouji Doihara
TSTakashi Shimada
Takashi Shimada
KCKar-Hooi Cheong
Kar-Hooi Cheong
YTYoshiya Terao
Yoshiya Terao

11 October 2005 in Experiments in Fluids
Verified
Journal Article
Closed access
PDF file
CIC. Iwaki
C. Iwaki
KCKar-Hooi Cheong
Kar-Hooi Cheong
HMH. Monji
H. Monji
GMG. Matsui
G. Matsui

8 June 2018 in Measurement Science and Technology
Verified
Journal Article
Closed access
PDF file
KCKar-Hooi Cheong
Kar-Hooi Cheong
RDRyouji Doihara
Ryouji Doihara
TSTakashi Shimada
Takashi Shimada
YTYoshiya Terao
Yoshiya Terao
This paper presents a gravimetric system developed to perform the static weighing with flying-start-and-stop (SW-FSS) calibration method at low liquid flow rates using a pair of identical high-speed switching valves as a flow diverter. Features of the gravimetric system comprise three main components: a pair of switching valves that divert the working liquid between two symmetrical flow paths; a weighing vessel equipped with an overflow inner vessel and enclosed in a weighing chamber; and a liquid discharge mechanism comprising a discharge tube and a discharge pump, used with a multi-purpose bin. These are described with an explanation of the design considerations behind each feature. The overflow inner vessel is designed with a notch in its wall and is positioned so that it does not come into contact with the liquid surface of the accumulated liquid in the weighing vessel or the side wall of the weighing vessel to obtain a good repeatability of the interactive effects between the feeding tube and the submerging working liquid, thus ensuring a correct mass reading of the liquid collection. A performance test showed that, in terms of contribution to the overall uncertainty of the standard flow rate, the pair of switching valves is capable of performing SW-FSS satisfactorily with small relative timing errors within %. However, the mass loss due to evaporation is considered a major source of error of the gravimetric system, showing a maximum error of 0.011% under the most evaporative condition tested for the longest liquid collection time of the gravimetric system.

1 December 2021 in Flow Measurement and Instrumentation
Verified
Journal Article
Closed access
NFNoriyuki Furuichi
Noriyuki Furuichi
KCKar-Hooi Cheong
Kar-Hooi Cheong
TYTaiki Yoshida
Taiki Yoshida

1 August 2017 in Flow Measurement and Instrumentation
Verified
Journal Article
Closed access
KCKar-Hooi Cheong
Kar-Hooi Cheong
RDRyouji Doihara
Ryouji Doihara
TSTakashi Shimada
Takashi Shimada
YTYoshiya Terao
Yoshiya Terao