Endotoxin is a bioaerosol component that is known to cause respiratory effects in exposed populations. To date, most research focused on occupational exposure, whilst much less is known about the impact of emissions from industrial operations on downwind endotoxin concentrations. A review of the literature was undertaken, identifying studies that reported endotoxin concentrations in both ambient environments and around sources with high endotoxin emissions. Ambient endotoxin concentrations in both rural and urban areas are generally below 10 endotoxin units (EU) m−3; however, around significant sources such as compost facilities, farms, and wastewater treatment plants, endotoxin concentrations regularly exceeded 100 EU m−3. However, this is affected by a range of factors including sampling approach, equipment, and duration. Reported downwind measurements of endotoxin demonstrate that endotoxin concentrations can remain above upwind concentrations. The evaluation of reported data is complicated due to a wide range of different parameters including sampling approaches, temperature, and site activity, demonstrating the need for a standardised methodology and improved guidance. Thorough characterisation of ambient endotoxin levels and modelling of endotoxin from pollution sources is needed to help inform future policy and support a robust health-based risk assessment process.
With the increase in composting asa sustainable waste management option, biological air pollution (bioaerosols) from composting facilities have become a cause of increasing concern due to their potential health impacts. Estimating community exposure to bioaerosols is problematic due to limitations in current monitoring methods. Atmospheric dispersion modelling can be used to estimate exposure concentrations, however several issues arise from the lack of appropriate bioaerosol data to use as inputs into models, and the complexity of the emission sources at composting facilities. This paper analyses current progress in using dispersion models for bioaerosols, examines the remaining problems and provides recommendations for future prospects in this area. A key finding is the urgent need for guidance for model users to ensure consistent bioaerosol modelling practices.
Bioaerosol emissions arising from biowaste treatment are an issue of public concern. To better characterise the bioaerosols, and to assess a range of measurement methods, we aerosolised green waste compost under controlled conditions. Viable and non-viable Andersen samplers, cyclone samplers and a real time bioaerosol detection system (Spectral Intensity Bioaerosol Sensor (SIBS)) were deployed simultaneously. The number-weighted fraction of fluorescent particles was in the range 22–26% of all particles for low and high emission scenarios. Overall fluorescence spectral profiles seen by the SIBS exhibited several peaks across the 16 wavelength bands from 298 to 735 nm. The size-fractionated endotoxin profile showed most endotoxin resided in the 2.1–9 μm aerodynamic diameter fraction, though up to 27% was found in a finer size fraction. A range of microorganisms were detected through culture, Matrix Assisted Laser Desorption and Ionisation Time of Flight Mass Spectrometry (MALDI-TOF) and quantitative polymerase chain reaction (qPCR), including Legionella pneumophila serogroup 1. These findings contribute to our knowledge of the physico-chemical and biological characteristics of bioaerosols from composting sites, as well as informing future monitoring approaches and data interpretation for bioaerosol measurement.
1 July 2016 in International Journal of Hygiene and Environmental Health
Large-scale composting can release bioaerosols in elevated quantities, but there are few studies of health effects on nearby communities. A cross-sectional ecological small area design was used to examine risk of respiratory hospital admissions within 2500m of all 148 English large-scale composting facilities in 2008-10. Statistical analyses used a random intercept Poisson regression model at Census Output Area (COA) level (mean population 310). Models were adjusted for age, sex, deprivation and tobacco sales. Analysing 34,963 respiratory hospital admissions in 4656 COAs within 250-2500m of a site, there were no significant trends using pre-defined distance bands of >250-750m, >750-1500m and >1500-2500m. Using a continuous measure of distance, there was a small non-statistically significant (p=0.054) association with total respiratory admissions corresponding to a 1.5% (95% CI: 0.0-2.9%) decrease in risk if moving from 251m to 501m. There were no significant associations for subgroups of respiratory infections, asthma or chronic obstructive pulmonary disease. This national study does not provide evidence for increased risks of respiratory hospital admissions in those living beyond 250m of an outdoor composting area perimeter. Further work using better measures of exposure and exploring associations with symptoms and disease prevalence, especially in vulnerable groups, is recommended to support regulatory approaches.
1 December 2016 in Journal of Environmental Management
Bioaerosols are released in elevated quantities from composting facilities and are associated with negative health effects, although dose-response relationships are not well understood, and require improved exposure classification. Dispersion modelling has great potential to improve exposure classification, but has not yet been extensively used or validated in this context. We present a sensitivity analysis of the ADMS dispersion model specific to input parameter ranges relevant to bioaerosol emissions from open windrow composting. This analysis provides an aid for model calibration by prioritising parameter adjustment and targeting independent parameter estimation. Results showed that predicted exposure was most sensitive to the wet and dry deposition modules and the majority of parameters relating to emission source characteristics, including pollutant emission velocity, source geometry and source height. This research improves understanding of the accuracy of model input data required to provide more reliable exposure predictions.
1 January 2017 in International Journal of Hygiene and Environmental Health
Bioaerosols are released in elevated quantities from composting facilities and are associated with negative health effects, although dose-response relationships are unclear. Exposure levels are difficult to quantify as established sampling methods are costly, time-consuming and current data provide limited temporal and spatial information. Confidence in dispersion model outputs in this context would be advantageous to provide a more detailed exposure assessment. We present the calibration and validation of a recognised atmospheric dispersion model (ADMS) for bioaerosol exposure assessments. The model was calibrated by a trial and error optimisation of observed Aspergillus fumigatus concentrations at different locations around a composting site. Validation was performed using a second dataset of measured concentrations for a different site. The best fit between modelled and measured data was achieved when emissions were represented as a single area source, with a temperature of 29°C. Predicted bioaerosol concentrations were within an order of magnitude of measured values (1000-10,000CFU/m3) at the validation site, once minor adjustments were made to reflect local differences between the sites (r2>0.7 at 150, 300, 500 and 600m downwind of source). Results suggest that calibrated dispersion modelling can be applied to make reasonable predictions of bioaerosol exposures at multiple sites and may be used to inform site regulation and operational management.