Thomas Foster Scherr

Dr. Thomas Foster Scherr

Department of Chemistry, Vanderbilt University, 1234 Stevenson Center Lane, Nashville, TN 37212, USA

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2012 in Bone
Verified
Journal Article
Closed access
JPJun Pan
Jun Pan
BWBin Wang
Bin Wang
WLWen Li
Wen Li
XZXiaozhou Zhou
Xiaozhou Zhou
Thomas Foster ScherrThomas Foster Scherr
Thomas Foster Scherr
LWLiyun Wang
Liyun Wang

16 April 2012 in Journal of Micromechanics and Microengineering
Verified
Journal Article
Closed access
Thomas Foster ScherrThomas Foster Scherr
Thomas Foster Scherr
CQChristian Quitadamo
Christian Quitadamo
PTPreston Tesvich
Preston Tesvich
DPDaniel Sang-Won Park
Daniel Sang-Won Park
TTTerrence Tiersch
Terrence Tiersch
WMWilliam Monroe
William Monroe
A passive, planar micromixer design based on logarithmic spirals is presented. The device was fabricated using polydimethylsiloxane soft photolithography techniques, and mixing performance was characterized via numerical simulation and fluorescent microscopy. Mixing efficiency initially declined as Reynolds number increased, and this trend continued until a Reynolds number of 15 where a minimum was reached at 53%. Mixing efficiency then began to increase reaching a maximum mixing efficiency of 86% at Re = 67. Three-dimensional simulations of fluid mixing in this design were compared to other planar geometries such as the Archimedes spiral and Meandering-S mixers. The implementation of logarithmic curvature offers several unique advantages that enhance mixing, namely a variable cross-sectional area and a logarithmically varying radius of curvature that creates 3-D Dean vortices. These flow phenomena were observed in simulations with multilayered fluid folding and validated with confocal microscopy. This design provides improved mixing performance over a broader range of Reynolds numbers than other reported planar mixers, all while avoiding external force fields, more complicated fabrication processes, and the introduction of flow obstructions or cavities that may unintentionally affect sensitive or particulate-containing samples. Due to the planar design requiring only single-step lithographic features, this compact geometry could be easily implemented into existing micro-total analysis systems requiring effective rapid mixing.

22 February 2017 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
Thomas Foster ScherrThomas Foster Scherr
Thomas Foster Scherr
SGSparsh Gupta
Sparsh Gupta
David W. WrightDavid W. Wright
David W. Wright
FHFrederick Haselton
Frederick Haselton
Barcode embedded rapid diagnostic tests are presented as a tool for improved communication in malaria elimination campaigns.

31 May 2015 in Biomedical Microdevices
Verified
Journal Article
Closed access
PDF file
Thomas Foster ScherrThomas Foster Scherr
Thomas Foster Scherr
GKGerald Laurence Knapp
Gerald Laurence Knapp
AGAmy Guitreau
Amy Guitreau
DPDaniel Sang-Won Park
Daniel Sang-Won Park
TTTerrence Tiersch
Terrence Tiersch
WMWilliam Monroe
William Monroe

1 January 2015 in Tissue Engineering Part A
Verified
Journal Article
Closed access
CCCong Chen
Cong Chen
LGLeah Garber
Leah Garber
MSMollie Smoak
Mollie Smoak
CFCarmel Fargason
Carmel Fargason
Thomas Foster ScherrThomas Foster Scherr
Thomas Foster Scherr
DHDaniel J. Hayes
Daniel J. Hayes
A thiol-acrylate-based copolymer synthesized via an amine-catalyzed Michael addition was studied in vitro and in vivo to assess its potential as an in situ polymerizing graft or augment in bone defect repair. The blends of hydroxyapatite (HA) with pentaerythritol triacrylate-co-trimethylolpropane (PETA), cast as solids or gas foamed as porous scaffolds, were evaluated in an effort to create a biodegradable osteogenic material for use as a bone-void-filling augment. Osteogenesis experiments were conducted with human adipose-derived mesenchymal stromal cells (hASCs) to determine the ability of the material to serve as an osteoinductive substrate. Poly(ɛ-caprolactone) (PCL) composites PCL:HA (80:20) (wt/wt%) served as the control scaffold, while the experimental scaffolds included PETA:HA (100:0), (85:15), (80:20), and (75:25) composites (wt/wt%). The results indicate that PETA:HA (80:20) foam composites had higher mechanical strength than the corresponding porous PCL:HA (80:20) scaffolds made by thermo-precipitation method, and in the case of foamed composites, increasing HA content directly correlated with increased yield strength. For cytotoxicity and osteogenesis experiments, hASCs cultured for 21 days on PETA:HA scaffolds in stromal medium displayed the greatest number of live cells compared with PCL:HA composites. Moreover, hASCs cultured on foamed PETA:HA (80:20) scaffolds resulted in the greatest mineralization, increased alkaline phosphatase (ALP) expression, and the highest osteocalcin (OCN) expression after 21 days. Overall, the PETA:HA (80:20) and PETA:HA (85:15) scaffolds, with 66.38% and 72.02% porosity, respectively, had higher mechanical strength and cytocompatibility compared with the PCL:HA control. The results of the 6-week in vivo biocompatibility study using a posterior lumbar spinal fusion model demonstrate that PETA:HA can be foamed in vivo without serious adverse effects at the surgical site. Additionally, it was demonstrated that cells migrate into the interconnected pore volume and are found within centers of ossification.

26 March 2021 in JMIR Public Health and Surveillance
Verified
Journal Article
Open access
Thomas Foster ScherrThomas Foster Scherr
Thomas Foster Scherr
JDJenna Maria DeSousa
Jenna Maria DeSousa
CMCarson Paige Moore
Carson Paige Moore
AHAustin Hardcastle
Austin Hardcastle
David W. WrightDavid W. Wright
David W. Wright
Background: The COVID-19 pandemic has drastically changed life in the United States, as the country has recorded over 23 million cases and 383,000 deaths to date. In the leadup to widespread vaccine deployment, testing and surveillance are critical for detecting and stopping possible routes of transmission. Contact tracing has become an important surveillance measure to control COVID-19 in the United States, and mobile health interventions have found increased prominence in this space. Objective: The aim of this study was to investigate the use and usability of MyCOVIDKey, a mobile-based web app to assist COVID-19 contact tracing efforts, during the 6-week pilot period. Methods: A 6-week study was conducted on the Vanderbilt University campus in Nashville, Tennessee. The study participants, consisting primarily of graduate students, postdoctoral researchers, and faculty in the Chemistry Department at Vanderbilt University, were asked to use the MyCOVIDKey web app during the course of the study period. Paradata were collected as users engaged with the MyCOVIDKey web app. At the end of the study, all participants were asked to report on their user experience in a survey, and the results were analyzed in the context of the user paradata. Results: During the pilot period, 45 users enrolled in MyCOVIDKey. An analysis of their enrollment suggests that initial recruiting efforts were effective; however, participant recruitment and engagement efforts at the midpoint of the study were less effective. App use paralleled the number of users, indicating that incentives were useful for recruiting new users to sign up but did not result in users attempting to artificially inflate their use as a result of prize offers. Times to completion of key tasks were low, indicating that the main features of the app could be used quickly. Of the 45 users, 30 provided feedback through a postpilot survey, with 26 (58%) completing it in its entirety. The MyCOVIDKey app as a whole was rated 70.0 on the System Usability Scale, indicating that it performed above the accepted threshold for usability. When the key-in and self-assessment features were examined on their own, it was found that they individually crossed the same thresholds for acceptable usability but that the key-in feature had a higher margin for improvement. Conclusions: The MyCOVIDKey app was found overall to be a useful tool for COVID-19 contact tracing in a university setting. Most users suggested simple-to-implement improvements, such as replacing the web app framework with a native app format or changing the placement of the scanner within the app workflow. After these updates, this tool could be readily deployed and easily adapted to other settings across the country. The need for digital contact tracing tools is becoming increasingly apparent, particularly as COVID-19 case numbers continue to increase while more businesses begin to reopen.