Magnetic Resonance Imaging (MRI) offers strong soft tissue contrast but suffers from long acquisition times and requires tedious annotation from radiologists. Traditionally, these challenges have been addressed separately with reconstruction and image analysis algorithms. To see if performance could be improved by treating both as end-to-end, we hosted the K2S challenge, in which challenge participants segmented knee bones and cartilage from 8× undersampled k-space. We curated the 300-patient K2S dataset of multicoil raw k-space and radiologist quality-checked segmentations. 87 teams registered for the challenge and there were 12 submissions, varying in methodologies from serial reconstruction and segmentation to end-to-end networks to another that eschewed a reconstruction algorithm altogether. Four teams produced strong submissions, with the winner having a weighted Dice Similarity Coefficient of 0.910 ± 0.021 across knee bones and cartilage. Interestingly, there was no correlation between reconstruction and segmentation metrics. Further analysis showed the top four submissions were suitable for downstream biomarker analysis, largely preserving cartilage thicknesses and key bone shape features with respect to ground truth. K2S thus showed the value in considering reconstruction and image analysis as end-to-end tasks, as this leaves room for optimization while more realistically reflecting the long-term use case of tools being developed by the MR community.
Corticosteroid injections were associated with higher progression of knee osteoarthritis compared with hyaluronic acid injections and controls, as determined by Whole-Organ MRI Score.
Objective: To assess the prevalence and clinical implications of variant sciatic nerve anatomy in relation to the piriformis muscle on magnetic resonance neurography (MRN), in patients with lumbosacral neuropathic symptoms. Materials and Methods: In this retrospective single-center study, 254 sciatic nerves, from 127 patients with clinical and imaging findings compatible with extra-spinal sciatica on MRN between 2003 and 2013, were evaluated for the presence and type of variant sciatic nerves, split sciatic nerve, abnormal T2-signal hyperintensity, asymmetric piriformis size and increased nerve caliber, and summarized using descriptive statistics. Two-tailed chi-square tests were performed to compare the anatomical variant type and clinical symptoms between imaging and clinical characteristics. Results: Sixty-four variant sciatic nerves were identified with an equal number of right and left variants. Bilateral variants were noted in 15 cases. Abnormal T2-signal hyperintensity was seen significantly more often in variant compared to conventional anatomy (40/64 vs. 82/190; p = 0.01). A sciatic nerve split was seen significantly more often in variant compared to conventional anatomy (56/64 vs. 20/190; p < 0.0001). Increased nerve caliber, abnormal T2-signal hyperintensity, and asymmetric piriformis size were significantly associated with the clinically symptomatic side compared to the asymptomatic side (98:2, 98:2, and 97:3, respectively; p < 0.0001 for all). Clinical symptoms were correlated with variant compared to conventional sciatic nerve anatomy (64% vs. 46%; p = 0.01). Conclusion: Variant sciatic nerve anatomy, in relation to the piriformis muscle, is frequently identified with MRN and is more likely to be associated with nerve signal changes and symptomatology.
15 September 2022 in American Journal of Neuroradiology
BACKGROUND AND PURPOSE: Quantitative metrics of the dural sac such as the cross-sectional area are commonly used to evaluate central canal stenosis. The aim of this study was to analyze 2 new metrics to measure spinal stenosis on the basis of the ratio between the dural sac and disc cross-sectional areas (DDRCA) and the dural sac and disc anterior-posterior diameters (DDRDIA) and compare them with established quantitative metrics of the dural sac. MATERIALS AND METHODS: T2-weighted axial MR images (n = 260 patients) were retrospectively evaluated, graded for central canal stenosis as normal (no stenosis), mild, moderate, or severe from L1/L2 through L5/S1 with 1 grade per spinal level and annotated to measure the DDRCA and DDRDIA. Thresholds were obtained using a decision tree classifier on a subset of patients (n = 130) and evaluated on the remaining patients (n = 130) for accuracy and consistency across demographics, anatomic variation, and clinical outcomes. RESULTS: DDRCA and DDRDIA had areas under the receiver operating characteristic curve of 98.6 (97.4–99.3) and 98.0 (96.7–98.9) compared with dural sac cross-sectional area at 96.5 (95.0–97.7) for binary classification. DDRDIA and DDRCA had κ scores of 0.75 (0.71–0.79) and 0.80 (0.75–0.83) compared with dural sac cross-sectional area at 0.62 (0.57–0.66) for multigrade classification. No significant differences (P > .1) in the area under the receiver operating characteristic curve were observed for the DDRDIA across variations in the body mass index. The DDRDIA also had the highest area under the receiver operating characteristic curve among symptomatic patients (visual analog scale ≥ 7) or patients who underwent surgery. CONCLUSIONS: Ratio-based metrics (DDRDIA and DDRCA) are accurate and robust to anatomic and demographic variability compared with quantitative metrics of the dural sac and better correlated with symptomatology and surgical outcomes.