Chih-Liang Chin

Chih-Liang Chin

Auto-generated profile, based on publicly available information

Chih-Liang Chin

From the Departments of Radiology and Biomedical Imaging (U.U.B., V.P., S.M., T.M.L., C.T.C.)

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 April 2019 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
HHH. Haraldsson
H. Haraldsson
JLJoseph Leach
Joseph Leach
EKE.I. Kao
E.I. Kao
AWA.G. Wright
A.G. Wright
SAS.G. Ammanuel
S.G. Ammanuel
MAM.R. Amans
M.R. Amans
BACKGROUND AND PURPOSE: Idiopathic intracranial hypertension is commonly associated with transverse sinus stenosis, a venous cause of pulsatile tinnitus. In patients with idiopathic intracranial hypertension, CSF drainage via lumbar puncture decreases intracranial pressure, which relieves the stenosis, and may provide at least temporary cessation of pulsatile tinnitus. The objective of this study was to evaluate changes in venous blood flow caused by lowered intracranial pressure in patients with pulsatile tinnitus to help identify the cause of pulsatile tinnitus. MATERIALS AND METHODS: Ten patients with suspected transverse sinus stenosis as a venous etiology for pulsatile tinnitus symptoms underwent MR imaging before and after lumbar puncture in the same session. The protocol included flow assessment and rating of pulsatile tinnitus intensity before and after lumbar puncture and MR venography before lumbar puncture. Post-lumbar puncture MR venography was performed in 1 subject. RESULTS: There was a lumbar puncture–induced reduction in venous peak velocity that correlated with the opening pressure (r = −0.72, P = .019) without a concomitant reduction in flow rate. Patients with flow jets had their peak velocity reduced by 0.30 ± 0.18 m/s (P = .002), correlating with a reduction in CSF pressure (r = 0.82, P = .024) and the reduction in subjectively scored pulsatile tinnitus intensity (r = 0.78, P = .023). The post-lumbar puncture MR venography demonstrated alleviation of the stenosis. CONCLUSIONS: Our results show a lumbar puncture–induced reduction in venous peak velocity without a concomitant reduction in flow rate. We hypothesize that the reduction is caused by the expansion of the stenosis after lumbar puncture. Our results further show a correlation between the peak velocity and pulsatile tinnitus intensity, suggesting the flow jet to be instrumental in the development of sound.

9 November 2017 in American Journal of Neuroradiology
Verified
Journal Article
Open access
PDF file
VSV.N. Shah
V.N. Shah
NFN.D. von Fischer
N.D. von Fischer
CCC.T. Chin
C.T. Chin
EYE.L. Yuh
E.L. Yuh
MAM.R. Amans
M.R. Amans
CHC.P. Hess
C.P. Hess
BACKGROUND AND PURPOSE: Lumbar facet synovial cysts are commonly seen in facet degenerative arthropathy and may be symptomatic when narrowing the spinal canal or compressing nerve roots. The purpose of this study was to analyze the safety, effectiveness, and long-term outcomes of direct CT-guided lumbar facet synovial cyst aspiration and fenestration for symptom relief and for obviating an operation. MATERIALS AND METHODS: We retrospectively reviewed the medical records and imaging studies of 64 consecutive patients between 2006 and 2016 who underwent 85 CT-guided lumbar facet synovial cyst fenestration procedures in our department. We recorded patient demographics, lumbar facet synovial cyst imaging characteristics, presenting symptoms, change in symptoms after the procedure, and whether they underwent a subsequent operation. We also assessed long-term outcomes from the medical records and via follow-up telephone surveys with patients. RESULTS: Direct CT-guided lumbar facet synovial cyst puncture was technically successful in 98% of procedures. At first postprocedural follow-up, 86% of patients had a complete or partial symptomatic response. During a mean follow-up of 49 months, 56% of patients had partial or complete long-term relief without the need for an operation; 44% of patients underwent an operation. Patients with calcified, thick-rimmed, or low T2 signal intensity cysts were less likely to respond to the procedure and more likely to need an operation. CONCLUSIONS: CT-guided direct lumbar facet synovial cyst aspiration and fenestration procedures are safe, effective, and minimally invasive for symptomatic treatment of lumbar synovial facet cysts. This procedure obviates an operation in a substantial number of patients, even at long-term follow-up, and should be considered before surgical intervention.

15 September 2022 in American Journal of Neuroradiology
Verified
Journal Article
Closed access
PDF file
UBUpasana Upadhyay Bharadwaj
Upasana Upadhyay Bharadwaj
ABA.R. Ben-Natan
A.R. Ben-Natan
JHJ. Huang
J. Huang
VPV. Pedoia
V. Pedoia
DCD. Chou
D. Chou
CCC.T. Chin
C.T. Chin
BACKGROUND AND PURPOSE: Quantitative metrics of the dural sac such as the cross-sectional area are commonly used to evaluate central canal stenosis. The aim of this study was to analyze 2 new metrics to measure spinal stenosis on the basis of the ratio between the dural sac and disc cross-sectional areas (DDRCA) and the dural sac and disc anterior-posterior diameters (DDRDIA) and compare them with established quantitative metrics of the dural sac. MATERIALS AND METHODS: T2-weighted axial MR images (n = 260 patients) were retrospectively evaluated, graded for central canal stenosis as normal (no stenosis), mild, moderate, or severe from L1/L2 through L5/S1 with 1 grade per spinal level and annotated to measure the DDRCA and DDRDIA. Thresholds were obtained using a decision tree classifier on a subset of patients (n = 130) and evaluated on the remaining patients (n = 130) for accuracy and consistency across demographics, anatomic variation, and clinical outcomes. RESULTS: DDRCA and DDRDIA had areas under the receiver operating characteristic curve of 98.6 (97.4–99.3) and 98.0 (96.7–98.9) compared with dural sac cross-sectional area at 96.5 (95.0–97.7) for binary classification. DDRDIA and DDRCA had κ scores of 0.75 (0.71–0.79) and 0.80 (0.75–0.83) compared with dural sac cross-sectional area at 0.62 (0.57–0.66) for multigrade classification. No significant differences (P > .1) in the area under the receiver operating characteristic curve were observed for the DDRDIA across variations in the body mass index. The DDRDIA also had the highest area under the receiver operating characteristic curve among symptomatic patients (visual analog scale ≥ 7) or patients who underwent surgery. CONCLUSIONS: Ratio-based metrics (DDRDIA and DDRCA) are accurate and robust to anatomic and demographic variability compared with quantitative metrics of the dural sac and better correlated with symptomatology and surgical outcomes.

26 May 2015 in PLOS ONE
Verified
Journal Article
Open access
PDF file
SSSmita Sampath
Smita Sampath
MKMichael Klimas
Michael Klimas
DFDai Feng
Dai Feng
RBRichard Baumgartner
Richard Baumgartner
EMElaine Manigbas
Elaine Manigbas
CCChih-Liang Chin
Chih-Liang Chin
Pre-clinical animal models are important to study the fundamental biological and functional mechanisms involved in the longitudinal evolution of heart failure (HF). Particularly, large animal models, like nonhuman primates (NHPs), that possess greater physiological, biochemical, and phylogenetic similarity to humans are gaining interest. To assess the translatability of these models into human diseases, imaging biomarkers play a significant role in non-invasive phenotyping, prediction of downstream remodeling, and evaluation of novel experimental therapeutics. This paper sheds insight into NHP cardiac function through the quantification of magnetic resonance (MR) imaging biomarkers that comprehensively characterize the spatiotemporal dynamics of left ventricular (LV) systolic pumping and LV diastolic relaxation. MR tagging and phase contrast (PC) imaging were used to quantify NHP cardiac strain and flow. Temporal inter-relationships between rotational mechanics, myocardial strain and LV chamber flow are presented, and functional biomarkers are evaluated through test-retest repeatability and inter subject variability analyses. The temporal trends observed in strain and flow was similar to published data in humans. Our results indicate a dominant dimension based pumping during early systole, followed by a torsion dominant pumping action during late systole. Early diastole is characterized by close to 65% of untwist, the remainder of which likely contributes to efficient filling during atrial kick. Our data reveal that moderate to good intra-subject repeatability was observed for peak strain, strain-rates, E/circumferential strain-rate (CSR) ratio, E/longitudinal strain-rate (LSR) ratio, and deceleration time. The inter-subject variability was high for strain dyssynchrony, diastolic strain-rates, peak torsion and peak untwist rate. We have successfully characterized cardiac function in NHPs using MR imaging. Peak strain, average systolic strain-rate, diastolic E/CSR and E/LSR ratios, and deceleration time were identified as robust biomarkers that could potentially be applied to future pre-clinical drug studies.

2 March 2018
Verified
Conference Paper
Closed access
PDF file
ACAntong Chen
Antong Chen
DZDongqing Zhang
Dongqing Zhang
IIIlknur Icke
Ilknur Icke
BDBelma Dogdas
Belma Dogdas
SPSarayu Parimal
Sarayu Parimal
CCChih-Liang Chin
Chih-Liang Chin
In the development of treatments for cardiovascular diseases, short axis cardiac cine MRI is important for the assessment of various structural and functional properties of the heart. In short axis cardiac cine MRI, Cardiac properties including the ventricle dimensions, stroke volume, and ejection fraction can be extracted based on accurate segmentation of the left ventricle (LV) myocardium. One of the most advanced segmentation methods is based on fully convolutional neural networks (FCN) and can be successfully used to do segmentation in cardiac cine MRI slices. However, the temporal dependency between slices acquired at neighboring time points is not used. Here, based on our previously proposed FCN structure, we proposed a new algorithm to segment LV myocardium in porcine short axis cardiac cine MRI by incorporating convolutional long short-term memory (Conv-LSTM) to leverage the temporal dependency. In this approach, instead of processing each slice independently in a conventional CNN-based approach, the Conv-LSTM architecture captures the dynamics of cardiac motion over time. In a leave-one-out experiment on 8 porcine specimens (3,600 slices), the proposed approach was shown to be promising by achieving average mean Dice similarity coefficient (DSC) of 0.84, Hausdorff distance (HD) of 6.35 mm, and average perpendicular distance (APD) of 1.09 mm when compared with manual segmentations, which improved the performance of our previous FCN-based approach (average mean DSC=0.84, HD=6.78 mm, and APD=1.11 mm). Qualitatively, our model showed robustness against low image quality and complications in the surrounding anatomy due to its ability to capture the dynamics of cardiac motion.