Muhammad Awais Bin Altaf

Dr. Muhammad Awais Bin Altaf

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 November 2012 in IEEE Journal of Solid-State Circuits
Verified
Journal Article
Closed access
JYJerald Yoo
Jerald Yoo
LYLong Yan
Long Yan
DEDina El-Damak
Dina El-Damak
MAMuhammad Awais Bin Altaf
Muhammad Awais Bin Altaf
ASAli H. Shoeb
Ali H. Shoeb
ACAnantha P. Chandrakasan
Anantha P. Chandrakasan
An 8-channel scalable EEG acquisition SoC is presented to continuously detect and record patient-specific seizure onset activities from scalp EEG. The SoC integrates 8 high-dynamic range Analog Front-End (AFE) channels, a machine-learning seizure classification processor and a 64 KB SRAM. The classification processor exploits the Distributed Quad-LUT filter architecture to minimize the area while also minimizing the overhead in power × delay . The AFE employs a Chopper-Stabilized Capacitive Coupled Instrumentation Amplifier to show NEF of 5.1 and noise RTI of 0.91 μV rms for 0.5-100 Hz bandwidth. The classification processor adopts a support-vector machine as a classifier, with a GBW controller that gives real-time gain and bandwidth feedback to AFE to maintain accuracy. The SoC is verified with the Children's Hospital Boston-MIT EEG database as well as with rapid eye blink pattern detection test. The SoC is implemented in 0.18 μm 1P6M CMOS process occupying 25 mm 2 , and it shows an accuracy of 84.4% in eye blink classification test, at 2.03 μJ/classification energy efficiency. The 64 KB on chip memory can store up to 120 seconds of raw EEG data.

26 October 2015 in IEEE Journal of Solid-State Circuits
Verified
Journal Article
Open access
MAMuhammad Awais Bin Altaf
Muhammad Awais Bin Altaf
CZChen Zhang
Chen Zhang
JYJerald Yoo
Jerald Yoo
A 16-channel noninvasive closed-loop beginning-and end-of-seizure detection SoC is presented. The dual-channel charge recycled (DCCR) analog front end (AFE) achieves chopping and time-multiplexing an amplifier between two channels simultaneously which exploits fast-settling DC servo-loop with current consumption and NEF of 0.9 μA/channel and 3.29/channel, respectively. The dual-detector architecture (D2A) classification processor utilizes two linear support-vector machine (LSVM) classifiers based on digital hysteresis to enhance both the sensitivity and the specificity simultaneously. The pulsating voltage transcranial electrical stimulator (PVTES) automatically configures the number of pulses to control the amount of charge delivered based on skin-electrode impedance variation in efforts to suppress the seizure activity, while burning only 2.45 μW. The 25 mm 2 SoC implemented in 0.18 μm CMOS consumes 2.73 μJ/classification for 16 channels with an average sensitivity, specificity, and latency of 95.7%, 98%, and 1 s, respectively.

16 April 2019 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Closed access
WSWala Saadeh
Wala Saadeh
SBSaad Adnan Butt
Saad Adnan Butt
MAMuhammad Awais Bin Altaf
Muhammad Awais Bin Altaf
Falls in! older adults are a major cause of morbidity and mortality and are a key class of preventable injuries. This paper presents a patient-specific (PS) fall prediction and detection prototype system that utilizes a single tri-axial accelerometer attached to the patient’s thigh to distinguish between activities of daily living (ADL) and fall events. The proposed system consists of two modes of operation: 1) fast mode for fall predication (FMFP) predicting a fall event (300msec-700msec) before occurring, 2) slow mode for fall detection (SMFD) with a 1-sec latency for detecting a fall event. The nonlinear Support Vector Machine Classifier (NLSVM)-based FMFP algorithm extracts 7 discriminating features for the pre-fall case to identify a fall risk event and alarm the patient. The proposed SMFD algorithm utilizes a Three-cascaded 1-sec sliding frames classification architecture with a linear regression-based offline training to identify a single and optimal threshold for each patient. Fall incidence will trigger an alarming notice to the concern healthcare providers via the internet. Experiments are performed with 20 different subjects (age above 65 years) and a total number of 100 associated falls and ADL recordings indoors and outdoors. The accuracy of the proposed algorithms is furthermore validated via MobiFall Dataset. FMFP achieves sensitivity and specificity of 97.8% and 99.1%, respectively, while SMFD achieves sensitivity and specificity of 98.6% and 99.3%, respectively, for a total number of 600 measured falls and ADL cases from 77 subjects.

7 July 2017 in IEEE Journal of Solid-State Circuits
Verified
Journal Article
Closed access
WSWala Saadeh
Wala Saadeh
MAMuhammad Awais Bin Altaf
Muhammad Awais Bin Altaf
HAHaneen Alsuradi
Haneen Alsuradi
JYJerald Yoo
Jerald Yoo
This paper presents a body-coupled communication (BCC) transceiver (TRX) that mitigates all the practical impairments of the body channel at once. The proposed pseudo orthogonal frequency-division multiplexing (P-OFDM) TRX combines baseband BPSK-OFDM with frequency-shift keying (FSK) to alleviate the impacts of variable ground effect and variable skin-electrode contact impedance, which have been the two major issues on the BCC. It can tolerate up to 20 dB of channel gain variation with measured bit error rate improvement of >70% compared to FSK modulation alone. The RC relaxed contact impedance monitor continuously monitors and compensates the variable skin-electrode contact impedance at both transmitter (TX) and receiver (RX). The proposed power-gated 8-point inverse fast Fourier transform/fast Fourier transform with no floating-point multipliers (FPMs) reduces the gate count and power by 54% and 30% compared to conventional FPMs, respectively. Additionally, the simple floating-point adder (FPA) reduces the gate count and energy consumption by 34% and 20% compared to conventional FPAs, respectively. A high input impedance glitch-free FSK demodulation RX with variable threshold limiter and all digital cycle correction is also proposed to support a scalable data rate (200 Kbps-2 Mbps). The 0.54 mm 2 TRX in 65-nm CMOS consumes 1.1 mW.

10 June 2019 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
WSWala Saadeh
Wala Saadeh
FKFatima Hameed Khan
Fatima Hameed Khan
MAMuhammad Awais Bin Altaf
Muhammad Awais Bin Altaf
Accurate monitoring of the depth of anesthesia (DoA) is essential for intraoperative and postoperative patient's health. Commercially available electroencephalograph (EEG)-based DoA monitors are recommended only for certain anesthetic drugs and specific age-group patients. This paper presents a machine learning classification processor for accurate DoA estimation irrespective of the patient's age and anesthetic drug. The classification is solely based on six features extracted from EEG signal, i.e. spectral edge frequency (SEF), beta ratio, and four bands of spectral energy (FBSE). A machine learning fine decision tree classifier is adopted to achieve a four-class DoA classification (deep, moderate, and light DoA versus awake state). The feature selection and the classification processor are optimized to achieve the highest classification accuracy for the state of moderate anesthesia required for the surgical operations. The proposed 256-point Fast Fourier Transform (FFT) accelerator is implemented to realize SEF, beta ratio and FBSE that enables minimal latency and high accuracy feature extraction. The proposed DoA processor is implemented using a 65nm CMOS technology and experimentally verified using FPGA based on the EEG recordings of 75 patients undergoing elective surgery with different types of anesthetic agents. The processor achieves an average accuracy of 92.2% for all DoA states, with a latency of 1 sec. The 0.09mm $^2$ DoA processor consumes 140nJ/classification.

24 January 2017 in IEEE Journal of Solid-State Circuits
Verified
Journal Article
Closed access
WSWala Saadeh
Wala Saadeh
MAMuhammad Awais Bin Altaf
Muhammad Awais Bin Altaf
HAHaneen Alsuradi
Haneen Alsuradi
JYJerald Yoo
Jerald Yoo
A power-efficient body-coupled communication pseudo orthogonal frequency-division multiplexing (P-OFDM) transceiver (TRX) is presented for binaural hearing aids (BHAs). Channel measurements are performed for different body postures between human head-to-hand and ear-to-ear to characterize the body channel path loss. The TRX exploits baseband 16-quadrature amplitude modulation OFDM symbols transmitted through a binary frequency-shift keying (FSK) modulation to mitigate the multipath and interference problems, which are the most serious issues in BHA, with bit error rate improvement of 74% compared to FSK. It is also free from the peak-to-average power ratio problem. A power-of-two decomposition constant multiplier is implemented to achieve area-efficient constant multiplications in 64-FFT. The proposed energy- and area-efficient miniaturized direct conversion FSK demodulation receiver is capable of demodulating up to 20 Mbps signals while reducing the area by >50% compared to conventional implementations. The 1 Mbps TRX is implemented in a 65 nm CMOS process with an active area of 2.13 mm² while consuming 1.4 mW.