Jerald Yoo

Jerald Yoo

Auto-generated profile, based on publicly available information

Jerald Yoo

Department of Electrical and Computer Engineering, Seoul National University, Seoul, South Korea

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 May 2007 in IEEE Transactions on Microwave Theory and Techniques
Verified
Journal Article
Closed access
NCNamjun Cho
Namjun Cho
JYJerald Yoo
Jerald Yoo
SSSeong-Jun Song
Seong-Jun Song
JLJeabin Lee
Jeabin Lee
SJSeonghyun Jeon
Seonghyun Jeon
HYHoi-Jun Yoo
Hoi-Jun Yoo
The human body characteristics as a signal transmission medium are studied for the application to intrabody communication. The measurements of the body channel cover the frequency range from 100 kHz to 150 MHz and the distance on the body up to 1.2 m. A distributed RC model is developed to analyze the large variation of the channel properties according to the frequency and channel length. The simulation results using the channel model match well with the measurements in both the frequency and time domains. The effect of the ground plane to the body channel transceivers is also investigated and an empirical formula for the minimum ground size is obtained. Finally, the amount of the electromagnetic radiation due to the body antenna effect is measured. With regards to the Federal Communications Commission regulations, the proper frequency range for the intrabody communication is determined to satisfy given bit error rate requirements

29 November 2012 in IEEE Journal of Solid-State Circuits
Verified
Journal Article
Closed access
JYJerald Yoo
Jerald Yoo
LYLong Yan
Long Yan
DEDina El-Damak
Dina El-Damak
MAMuhammad Awais Bin Altaf
Muhammad Awais Bin Altaf
ASAli H. Shoeb
Ali H. Shoeb
ACAnantha P. Chandrakasan
Anantha P. Chandrakasan
An 8-channel scalable EEG acquisition SoC is presented to continuously detect and record patient-specific seizure onset activities from scalp EEG. The SoC integrates 8 high-dynamic range Analog Front-End (AFE) channels, a machine-learning seizure classification processor and a 64 KB SRAM. The classification processor exploits the Distributed Quad-LUT filter architecture to minimize the area while also minimizing the overhead in power × delay . The AFE employs a Chopper-Stabilized Capacitive Coupled Instrumentation Amplifier to show NEF of 5.1 and noise RTI of 0.91 μV rms for 0.5-100 Hz bandwidth. The classification processor adopts a support-vector machine as a classifier, with a GBW controller that gives real-time gain and bandwidth feedback to AFE to maintain accuracy. The SoC is verified with the Children's Hospital Boston-MIT EEG database as well as with rapid eye blink pattern detection test. The SoC is implemented in 0.18 μm 1P6M CMOS process occupying 25 mm 2 , and it shows an accuracy of 84.4% in eye blink classification test, at 2.03 μJ/classification energy efficiency. The 64 KB on chip memory can store up to 120 seconds of raw EEG data.

22 December 2009 in IEEE Journal of Solid-State Circuits
Verified
Journal Article
Closed access
JYJerald Yoo
Jerald Yoo
LYLong Yan
Long Yan
SLSeulki Lee
Seulki Lee
YKYongsang Kim
Yongsang Kim
HYHoi-Jun Yoo
Hoi-Jun Yoo
A self-configured body sensor network controller and a high efficiency wirelessly powered sensor are presented for a wearable, continuous health monitoring system. The sensor chip harvests its power from the surrounding health monitoring band using an Adaptive Threshold Rectifier (ATR) with 54.9% efficiency, and it consumes 12 μW to implement an electrocardiogram (ECG) analog front-end and an ADC. The ATR is implemented with a standard CMOS process for low cost. The adhesive bandage type sensor patch is composed of the sensor chip, a Planar-Fashionable Circuit Board (P-FCB) inductor, and a pair of dry P-FCB electrodes. The dry P-FCB electrodes enable long term monitoring without skin irritation. The network controller automatically locates the sensor position, configures the sensor type (self-configuration), wirelessly provides power to the configured sensors, and transacts data with only the selected sensors while dissipating 5.2 mW at a single 1.8 V supply. Both the sensor and the health monitoring band are implemented using P-FCB for enhanced wearability and for lower production cost. The sensor chip and the network controller chip occupy 4.8 mm 2 and 15.0 mm 2 , respectively, including pads, in standard 0.18 μm 1P6M CMOS technology.

26 October 2015 in IEEE Journal of Solid-State Circuits
Verified
Journal Article
Open access
MAMuhammad Awais Bin Altaf
Muhammad Awais Bin Altaf
CZChen Zhang
Chen Zhang
JYJerald Yoo
Jerald Yoo
A 16-channel noninvasive closed-loop beginning-and end-of-seizure detection SoC is presented. The dual-channel charge recycled (DCCR) analog front end (AFE) achieves chopping and time-multiplexing an amplifier between two channels simultaneously which exploits fast-settling DC servo-loop with current consumption and NEF of 0.9 μA/channel and 3.29/channel, respectively. The dual-detector architecture (D2A) classification processor utilizes two linear support-vector machine (LSVM) classifiers based on digital hysteresis to enhance both the sensitivity and the specificity simultaneously. The pulsating voltage transcranial electrical stimulator (PVTES) automatically configures the number of pulses to control the amount of charge delivered based on skin-electrode impedance variation in efforts to suppress the seizure activity, while burning only 2.45 μW. The 25 mm 2 SoC implemented in 0.18 μm CMOS consumes 2.73 μJ/classification for 16 channels with an average sensitivity, specificity, and latency of 95.7%, 98%, and 1 s, respectively.

29 September 2009 in IEEE Transactions on Information Technology in Biomedicine
Verified
Journal Article
Closed access
JYJerald Yoo
Jerald Yoo
LYLong Yan
Long Yan
SLSeulki Lee
Seulki Lee
HKHyejung Kim
Hyejung Kim
HYHoi-Jun Yoo
Hoi-Jun Yoo
A wearable electrocardiogram (ECG) acquisition system implemented with planar-fashionable circuit board (P-FCB)-based shirt is presented. The proposed system removes cumbersome wires from conventional Holter monitor system for convenience. Dry electrodes screen-printed directly on fabric enables long-term monitoring without skin irritation. The ECG monitoring shirt exploits a monitoring chip with a group of electrodes around the body, and both the electrodes and the interconnection are implemented using P-FCB to enhance wearability and to lower production cost. The characteristics of P-FCB electrode are shown, and the prototype hardware is implemented to successfully verify the proposed concept.

24 April 2024 in Nature Communications
Verified
Journal Article
Open access
PDF file
JSJia Si
Jia Si
SYShuhan Yang
Shuhan Yang
YCYunuo Cen
Yunuo Cen
JCJiaer Chen
Jiaer Chen
YHYingna Huang
Yingna Huang
HYHyunsoo Yang
Hyunsoo Yang
The growth of artificial intelligence leads to a computational burden in solving non-deterministic polynomial-time (NP)-hard problems. The Ising computer, which aims to solve NP-hard problems faces challenges such as high power consumption and limited scalability. Here, we experimentally present an Ising annealing computer based on 80 superparamagnetic tunnel junctions (SMTJs) with all-to-all connections, which solves a 70-city traveling salesman problem (TSP, 4761-node Ising problem). By taking advantage of the intrinsic randomness of SMTJs, implementing global annealing scheme, and using efficient algorithm, our SMTJ-based Ising annealer outperforms other Ising schemes in terms of power consumption and energy efficiency. Additionally, our approach provides a promising way to solve complex problems with limited hardware resources. Moreover, we propose a cross-bar array architecture for scalable integration using conventional magnetic random-access memories. Our results demonstrate that the SMTJ-based Ising computer with high energy efficiency, speed, and scalability is a strong candidate for future unconventional computing schemes.