Yunlong Ma

Dr. Yunlong Ma

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 September 2017 in Energies
Verified
Journal Article
Open access
PDF file
YMYunlong Ma
Yunlong Ma
Suvash SahaSuvash Saha
Suvash Saha
WMWendy Miller
Wendy Miller
LGLisa Guan
Lisa Guan
This study has investigated the feasibility of three different solar-assisted air conditioning systems for typical medium-sized office buildings in all eight Australian capital cities using the whole building energy simulation software EnergyPlus. The studied solar cooling systems include: solar desiccant-evaporative cooling (SDEC) system, hybrid solar desiccant-compression cooling (SDCC) system, and solar absorption cooling (SAC) system. A referenced conventional vapor compression variable-air-volume (VAV) system has also been investigated for comparison purpose. The technical, environmental, and economic performances of each solar cooling system have been evaluated in terms of solar fraction (SF), system coefficient of performance (COP), annual HVAC (heating, ventilation, and air conditioning) electricity consumption, annual CO2 emissions reduction, payback period (PBP), and net present value (NPV). The results demonstrate that the SDEC system consumes the least energy in Brisbane and Darwin, achieving 56.9% and 82.1% annual energy savings, respectively, compared to the conventional VAV system, while for the other six cities, the SAC system is the most energy efficient. However, from both energy and economic aspects, the SDEC system is more feasible in Adelaide, Brisbane, Darwin, Melbourne, Perth, and Sydney because of high annual SF and COP, low yearly energy consumption, short PBP and positive NPV, while for Canberra and Hobart, although the SAC system achieves considerable energy savings, it is not economically beneficial due to high initial cost. Therefore, the SDEC system is the most economically beneficial for most of Australian cities, especially in hot and humid climates. The SAC system is also energy efficient, but is not as economic as the SDEC system. However, for Canberra and Hobart, reducing initial cost is the key point to achieve economic feasibility of solar cooling applications.

1 January 2015 in Procedia Engineering
Verified
Journal Article
Open access
YMYunlong Ma
Yunlong Ma
LGLisa Guan
Lisa Guan
This paper evaluates and compares the system performance of a solar desiccant-evaporative cooling (SDEC) system with a referenced conventional variable air volume (VAV) system for a typical office building in all 8 Australian capital cities. A simulation model of the building is developed using the whole building simulation software EnergyPlus. The performance indicators for the comparison are system coefficient of performance (COP), annual primary energy consumption, annual energy savings, and annual CO2 emissions reduction. The simulation results show that Darwin has the most apparent advantages for SDEC system applications with an annual energy savings of 557 GJ and CO2 emission reduction of 121 tonnes. The maximum system COP is 7. For other climate zones such as Canberra, Hobart and Melbourne, the SDEC system is not as energy efficient as the conventional VAV system

28 July 2022 in Buildings
Verified
Journal Article
Open access
PDF file
Aaron LiuAaron Liu
Aaron Liu
YMYunlong Ma
Yunlong Ma
WMWendy Miller
Wendy Miller
Bo XiaBo Xia
Bo Xia
SZSherif Zedan
Sherif Zedan
BBBruce Bonney
Bruce Bonney
Healthcare buildings often have high energy use intensity, which is potentially influenced by a few factors, such as occupancy and climate. A suite of data analysis methods, including principal component analysis and regressions, is applied to analyse monthly electricity data of a modern major hospital in subtropical Australia. The analysis shows that occupancy is not highly correlated with the hospital’s electricity use, nor is it important for building energy modelling. However, outdoor environment temperature is highly correlated with the hospital’s electricity use. Then, the hospital’s electricity uses in 2030 to 2090 scenarios are forecast with future climate files. The impacts are analysed in terms of bill increases and renewable capacity needed to offset the increased electricity use. This study has established a process to predict future hospital energy use using data-driven energy modelling. This succinct article provides vital evidence to support the healthcare sector to continuously improve energy efficiency for health buildings, which is a major asset to adapt to the changing climate.

19 August 2022 in Buildings
Verified
Journal Article
Open access
PDF file
YMYunlong Ma
Yunlong Ma
SZSherif Zedan
Sherif Zedan
Aaron LiuAaron Liu
Aaron Liu
WMWendy Miller
Wendy Miller
The high energy use of hospitals and healthcare facilities globally contributes to greenhouse gas emissions. At the same time, a large percentage of this energy use is attributed to space heating, cooling and ventilation, and is hence correlated to the climate. While the energy performance of Australian hospitals at the design stage is evaluated using historical weather data, the impact of the warming climate on Australian hospitals into the future remains unknown. The research question addressed is: What is the impact of future climates on the energy use of Australian hospitals built with the current design conditions? Two archetype hospital models were developed (a small single-story healthcare facility and a large multi-story hospital). DesignBuilder was used to simulate the performance of these models in 10 locations, ranging from the tropics to cool temperate regions in Australia. Current (1990–2015) and future climate files (2030, 2050, 2070 and 2090) were used. The results show that with the warming climate, the heating demand decreased, while the cooling demand increased for both hospital models for all sites. Cooling dominated climates, such as Darwin and Brisbane, were significantly impacted by the changing climates due to a substantial increase in cooling energy use. Heating based climates, such as Hobart and Canberra, resulted in an overall small reduction in total building energy use. In addition, the single-story facility was more impacted by the change in climate (in terms of energy use intensity) than the multi-story facility. The study highlights the importance of future climate files in building simulation and decarbonization planning.

25 June 2017 in Energies
Verified
Journal Article
Open access
PDF file
YMYunlong Ma
Yunlong Ma
Suvash SahaSuvash Saha
Suvash Saha
WMWendy Miller
Wendy Miller
LGLisa Guan
Lisa Guan
Solar desiccant cooling is widely considered as an attractive replacement for conventional vapor compression air conditioning systems because of its environmental friendliness and energy efficiency advantages. The system performance of solar desiccant cooling strongly depends on the input parameters associated with the system components, such as the solar collector, storage tank and backup heater, etc. In order to understand the implications of different design parameters on the system performance, this study has conducted a parametric analysis on the solar collector area, storage tank volume, and backup heater capacity of a solid solar desiccant cooling system for an office building in Brisbane, Australia climate. In addition, a parametric analysis on the outdoor air humidity ratio control set-point which triggers the operation of the desiccant wheel has also been investigated. The simulation results have shown that either increasing the storage tank volume or increasing solar collector area would result in both increased solar fraction (SF) and system coefficient of performance (COP), while at the same time reduce the backup heater energy consumption. However, the storage tank volume is more sensitive to the system performance than the collector area. From the economic aspect, a storage capacity of 30 m3/576 m2 has the lowest life cycle cost (LCC) of $405,954 for the solar subsystem. In addition, 100 kW backup heater capacity is preferable for the satisfaction of the design regeneration heating coil hot water inlet temperature set-point with relatively low backup heater energy consumption. Moreover, an outdoor air humidity ratio control set-point of 0.008 kgWater/kgDryAir is more reasonable, as it could both guarantee the indoor design conditions and achieve low backup heater energy consumption.