Wendy Miller

Dr. Wendy Miller

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2017 in International Journal of Engineering Business Management
Verified
Journal Article
Open access
SZSherif Zedan
Sherif Zedan
WMWendy Miller
Wendy Miller
Energy-efficient housing is a product that integrates various stakeholders’ tasks throughout the different stages of its life cycle. The relationships between these stakeholders impact on the degree of knowledge sharing and informed decision-making and can potentially enhance or lower the energy efficiency of the product – the house. This article uses a social network analysis (SNA) approach to visualize the social networks of the stakeholders of a number of owner-occupied housing case studies in Australia. The aim is to analyse, contrast and quantify the degrees of connectivity and centrality of the housing stakeholders to identify which groups have more connectivity in the stakeholders’ network of energy-efficiency housing and consequently more potential to influence the energy efficiency outcomes and which practices are more likely to enhance transparency and information sharing that is essential for producing energy-efficient housing.

Lisa CoulburnLisa Coulburn
Lisa Coulburn
WMWendy Miller
Wendy Miller
In response to an Australian governmental inquiry into biotoxin-related illness, the purpose of this integrative review is to bring together the current state of evidence on the prevalence, risk factors and impacts related to mould-affected housing in an Australian context, in order to inform building, housing and health research, practice and policy. The robust integrative review methodology simultaneously sought quantitative and qualitative studies and grey literature from multiple disciplines, identifying only 45 studies directly relating to Australian housing and indoor mould. Twenty-one studies highlight negative health impacts relating to indoor residential mould, with asthma, respiratory, allergy conditions and emerging health concerns for chronic multiple-symptom presentation. The majority of studies reported risk factors for indoor mould including poor housing conditions, poor-quality rental accommodation, socioeconomic circumstance, age-related housing issues and concerns for surface/interstitial condensation and building defects in newer housing. Risks for indoor mould in both older and newer housing raise concerns for the extent of the problem of indoor mould in Australia. Understanding the national prevalence of housing risks and “root cause” associated with indoor mould is not conclusive from the limited existing evidence. Synthesis of this evidence reveals a lack of coverage on: (1) national and geographical representation, (2) climatical coverage, (3) housing typologies, (4) housing defects, (5) maintenance, (6) impact from urbanisation, and (7) occupant’s behaviour. This integrative review was key in identifying emerging housing and health concerns, highlighting gaps in data and implications to be addressed by researchers, practice and policy and acts as a comprehensive holistic review process that can be applied to other countries.

1 November 2017 in Sustainable Cities and Society
Verified
Journal Article
Closed access
WMWendy Miller
Wendy Miller
MSManisha Senadeera
Manisha Senadeera

1 December 2015 in Sustainable Cities and Society
Verified
Journal Article
Closed access
WMWendy Miller
Wendy Miller

1 February 2017 in Energy Policy
Verified
Journal Article
Open access
WMWendy Miller
Wendy Miller
DVDesley Vine
Desley Vine
ZAZakaria Amin
Zakaria Amin
Global population ageing has significant implications for public policy in areas such as health, housing and economic security. The notion of housing as a public health issue is not new, yet very little research has examined the links between housing specifically built for older people, energy performance and occupant health and economic security. Utilising a case study approach, this research examined the interplay between the energy efficiency of housing explicitly designed for this demographic, the thermal efficiency of their dwellings, and the impact on internal temperatures and monthly energy costs. The study shows that the thermal efficiency of the dwellings is not the same across all dwellings, impacting the internal temperatures experienced by the elderly occupants and their finances. This has implications for energy efficiency policy, policy governing the energy performance of buildings specifically designed for older people, as well as the mandatory disclosure of building performance. The study highlights in particular the need for energy policy to be further refined to link the thermal performance requirements of buildings to the broader health care plan and specific needs of older people

22 September 2017 in Energies
Verified
Journal Article
Open access
PDF file
YMYunlong Ma
Yunlong Ma
Suvash SahaSuvash Saha
Suvash Saha
WMWendy Miller
Wendy Miller
LGLisa Guan
Lisa Guan
This study has investigated the feasibility of three different solar-assisted air conditioning systems for typical medium-sized office buildings in all eight Australian capital cities using the whole building energy simulation software EnergyPlus. The studied solar cooling systems include: solar desiccant-evaporative cooling (SDEC) system, hybrid solar desiccant-compression cooling (SDCC) system, and solar absorption cooling (SAC) system. A referenced conventional vapor compression variable-air-volume (VAV) system has also been investigated for comparison purpose. The technical, environmental, and economic performances of each solar cooling system have been evaluated in terms of solar fraction (SF), system coefficient of performance (COP), annual HVAC (heating, ventilation, and air conditioning) electricity consumption, annual CO2 emissions reduction, payback period (PBP), and net present value (NPV). The results demonstrate that the SDEC system consumes the least energy in Brisbane and Darwin, achieving 56.9% and 82.1% annual energy savings, respectively, compared to the conventional VAV system, while for the other six cities, the SAC system is the most energy efficient. However, from both energy and economic aspects, the SDEC system is more feasible in Adelaide, Brisbane, Darwin, Melbourne, Perth, and Sydney because of high annual SF and COP, low yearly energy consumption, short PBP and positive NPV, while for Canberra and Hobart, although the SAC system achieves considerable energy savings, it is not economically beneficial due to high initial cost. Therefore, the SDEC system is the most economically beneficial for most of Australian cities, especially in hot and humid climates. The SAC system is also energy efficient, but is not as economic as the SDEC system. However, for Canberra and Hobart, reducing initial cost is the key point to achieve economic feasibility of solar cooling applications.