Jinghua Yu

Prof. Jinghua Yu

School of Chemistry and Chemical Engineering, University of Jinan, Jinan, China
orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2012 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
SWShoumei Wang
Shoumei Wang
LGLei Ge
Lei Ge
XSXianrang Song
Xianrang Song
JYJinghua Yu
Jinghua Yu
SGShenguang Ge
Shenguang Ge
FZFang Zeng
Fang Zeng

1 February 2012 in Biomaterials
Verified
Journal Article
Closed access
LGLei Ge
Lei Ge
JYJixian Yan
Jixian Yan
XSXianrang Song
Xianrang Song
MYMei Yan
Mei Yan
SGShenguang Ge
Shenguang Ge
JYJinghua Yu
Jinghua Yu

7 January 2019 in Advanced Materials
Verified
Journal Article
Closed access
PDF file
CGChaomin Gao
Chaomin Gao
TWTao Wei
Tao Wei
YZYanyan Zhang
Yanyan Zhang
XSXiaohan Song
Xiaohan Song
YHYu Huan
Yu Huan
XCXiaodong Chen
Xiaodong Chen

31 July 2018 in Advanced Materials
Verified
Journal Article
Closed access
PDF file
YZYan Zhang
Yan Zhang
LZLina Zhang
Lina Zhang
KCKang Cui
Kang Cui
SGShenguang Ge
Shenguang Ge
XCXin Cheng
Xin Cheng
Hong LiuHong Liu
Hong Liu

18 January 2011 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
JYJinghua Yu
Jinghua Yu
LGLei Ge
Lei Ge
JHJiadong Huang
Jiadong Huang
SWShoumei Wang
Shoumei Wang
SGShenguang Ge
Shenguang Ge
In this study, a novel microfluidic paper-based chemiluminescence analytical device (μPCAD) with a simultaneous, rapid, sensitive and quantitative response for glucose and uric acid was designed. This novel lab-on-paper biosensor is based on oxidase enzyme reactions (glucose oxidase and urate oxidase, respectively) and the chemiluminescence reaction between a rhodanine derivative and generated hydrogen peroxide in an acid medium. The possible chemiluminescence assay principle of this μPCAD is explained. We found that the simultaneous determination of glucose and uric acid could be achieved by differing the distances that the glucose and uric acid samples traveled. This lab-on-paper biosensor could provide reproducible results upon storage at 4 °C for at least 10 weeks. The application test of our μPCAD was then successfully performed with the simultaneous determination of glucose and uric acid in artificial urine. This study shows the successful integration of the μPCAD and the chemiluminescence method will be an easy-to-use, inexpensive, and portable alternative for point-of-care monitoring.

30 May 2012 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
LGLei Ge
Lei Ge
SWShoumei Wang
Shoumei Wang
XSXianrang Song
Xianrang Song
SGShenguang Ge
Shenguang Ge
JYJinghua Yu
Jinghua Yu
A novel 3D microfluidic paper-based immunodevice, integrated with blood plasma separation from whole blood samples, automation of rinse steps, and multiplexed CL detections, was developed for the first time based on the principle of origami (denoted as origami-based device). This 3D origami-based device, comprised of one test pad surrounded by four folding tabs, could be patterned and fabricated by wax-printing on paper in bulk. In this work, a sandwich-type chemiluminescence (CL) immunoassay was introduced into this 3D origami-based immunodevice, which could separate the operational procedures into several steps including (i) folding pads above/below and (ii) addition of reagent/buffer under a specific sequence. The CL behavior, blood plasma separation, washing protocol, and incubation time were investigated in this work. The developed 3D origami-based CL immunodevice, combined with a typical luminuol-H2O2 CL system and catalyzed by Ag nanoparticles, showed excellent analytical performance for the simultaneous detection of four tumor markers. The whole blood samples were assayed and the results obtained were in agreement with the reference values from the parallel single-analyte test. This paper-based microfluidic origami CL detection system provides a new strategy for a low-cost, sensitive, simultaneous multiplex immunoassay and point-of-care diagnostics.