The present study aims to investigate whether the cochlear implant electrode array design affects the electrophysiological and psychophysical measures. Eighty five ears were used as data in this retrospective study. They were divided into two groups by the electrode array design: lateral wall type (LW) and perimodiolar type (PM). The electrode site was divided into three regions (basal, medial, apical). The evoked compound action potential (ECAP) threshold, T level, C level, dynamic range (DR), and aided air conduction threshold were measured. The ECAP threshold was lower for the PM than for the LW, and decreased as the electrode site was closer to the apical region. The T level was lower for the PM than for the LW, and was lower on the apical region than on the other regions. The C level on the basal region was lower for the PM than for the LW whereas the C level was lower on the apical region than on the other regions. The DRs on the apical region was greater for the PM than for the LW whereas the DR was narrower on the apical region than on the other regions. The aided air conduction threshold was not different for the electrode design and frequency. The current study would support the advantages of the PM over the LW in that the PM had the lower current level and greater DR, which could result in more localized neural stimulation and reduced power consumption.
1 January 2022 in Journal of Korean Medical Science
Background: It has been noted in the literature that there is a gap between clinical assessment and real-world performance. Real-world conversations entail visual and audio information, yet there are not any audiological assessment tools that include visual information. Virtual reality (VR) technology has been applied to various areas, including audiology. However, the use of VR in speech-in-noise perception has not yet been investigated. Objective: The purpose of this study was to investigate the impact of virtual space (VS) on speech performance and its feasibility to be used as a speech test instrument. We hypothesized that individuals’ ability to recognize speech would improve when visual cues were provided. Methods: A total of 30 individuals with normal hearing and 25 individuals with hearing loss completed pure-tone audiometry and the Korean version of the Hearing in Noise Test (K-HINT) under three conditions—conventional K-HINT (cK-HINT), VS on PC (VSPC), and VS head-mounted display (VSHMD)—at –10 dB, –5 dB, 0 dB, and +5 dB signal-to-noise ratios (SNRs). Participants listened to target speech and repeated it back to the tester for all conditions. Hearing aid users in the hearing loss group completed testing under unaided and aided conditions. A questionnaire was administered after testing to gather subjective opinions on the headset, the VSHMD condition, and test preference. Results: Provision of visual information had a significant impact on speech performance between the normal hearing and hearing impaired groups. The Mann-Whitney U test showed statistical significance (P<.05) between the two groups under all test conditions. Hearing aid use led to better integration of audio and visual cues. Statistical significance through the Mann-Whitney U test was observed for –5 dB (P=.04) and 0 dB (P=.02) SNRs under the cK-HINT condition, as well as for –10 dB (P=.007) and 0 dB (P=.04) SNRs under the VSPC condition, between hearing aid and non–hearing aid users. Participants reported positive responses across almost all items on the questionnaire except for the weight of the headset. Participants preferred a test method with visual imagery, but found the headset to be heavy. Conclusions: Findings are in line with previous literature that showed that visual cues were beneficial for communication. This is the first study to include hearing aid users with a more naturalistic stimulus and a relatively simple test environment, suggesting the feasibility of VR audiological testing in clinical practice.
Face masks are mandatory during the COVID-19 pandemic, leading to attenuation of sound energy and loss of visual cues which are important for communication. This study explores how a face mask affects speech performance for individuals with and without hearing loss. Four video recordings (a female speaker with and without a face mask and a male speaker with and without a face mask) were used to examine individuals’ speech performance. The participants completed a listen-and-repeat task while watching four types of video recordings. Acoustic characteristics of speech signals based on mask type (no mask, surgical, and N95) were also examined. The availability of visual cues was beneficial for speech understanding—both groups showed significant improvements in speech perception when they were able to see the speaker without the mask. However, when the speakers were wearing the mask, no statistical significance was observed between no visual cues and visual cues conditions. Findings of the study demonstrate that provision of visual cues is beneficial for speech perception for individuals with normal hearing and hearing impairment. This study adds value to the importance of the use of communication strategies during the pandemic where visual information is lost due to the face mask.
1 February 2022 in Clinical and Experimental Otorhinolaryngology
Objectives. This study was conducted to investigate the electroacoustic characteristics of personal sound amplification products (PSAPs), to identify whether PSAPs provide adequate gain and output for three common hearing loss (HL) configurations, and to compare the benefits of a representative PSAP (RPSAP) and a conventional hearing aid (HA) for clinical hearing outcomes as a pilot study.Methods. The study comprised three phases: electroacoustic analysis, simulated real-ear measurements (REMs), and clinical hearing experiments. Electroacoustic analysis and simulated REMs were performed for three basic PSAPs (BeethoSOL, EarJJang, and Geniesori2) and three high-end PSAPs (Hearing Able, Olive Smart Ear, and SoriIn) using the Aurical Hearing Instrument Test box with a 2-mL coupler. Four electroacoustic characteristics (maximum output sound pressure level at 90 dB SPL, frequency range, equivalent input noise, and total harmonic distortion) were investigated. By simulated REMs, appropriate levels of the six PSAPs for three common HL configurations (mild-to-moderate high-frequency HL, moderate to moderately severe sloping HL, and moderate flat HL) were determined. Clinical experiments compared the performance of RPSAP to HA, both of which were fitted by audiologists using REMs. Clinical experiments were administered using functional gain, a word recognition test, and the Korean version of the Hearing in Noise Test in six participants with bilateral moderate sensorineural HL.Results. The two high-end devices met all tolerances. One basic and two high-end PSAPs showed appropriate levels for three common HL configurations. In the clinical experiments, the RPSAP showed better performance than unaided, but slightly worse than HA under all test conditions.Conclusion. Certain PSAPs met all specified tolerances for electroacoustic analysis and approximated prescriptive targets in well-controlled laboratory conditions. The pilot clinical experiments explored the possibility that the RPSAP could serve as a hearing assistive device for patients with moderate HL.
31 May 2022 in Clinical and Experimental Otorhinolaryngology
The market for hearing technology is evolving—with the emergence of hearables, it now extends beyond hearing aids and includes any ear-level devices with wireless connectivity (i.e., wireless earbuds). However, will this evolving marketplace bring forth opportunities or challenges to individuals’ hearing health care and the profession of audiology and otolaryngology? The debate has been ongoing. This study explores the wide spectrum of hearables available in the market and discusses the necessity of high-quality clinical evidence prior to the implementation of over-the-counter devices into clinical practice.