Ga-Young Kim

Ga-Young Kim

Auto-generated profile, based on publicly available information

Ga-Young Kim

Hearing Research Laboratory, Samsung Medical Center, Seoul, Korea

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2022 in Journal of Korean Medical Science
Verified
Journal Article
Open access
PDF file
YCYoung Sang Cho
Young Sang Cho
GKGa-Young Kim
Ga-Young Kim
JCJae Hyuk Choi
Jae Hyuk Choi
SBSin Sung Baek
Sin Sung Baek
HSHye Yoon Seol
Hye Yoon Seol
IMIl Joon Moon
Il Joon Moon
Cho YS, et al. J Korean Med Sci. 2021 Dec;37(2):e11. https://doi.org/10.3346/jkms.2022.37.e11

1 February 2022 in Clinical and Experimental Otorhinolaryngology
Verified
Journal Article
Open access
PDF file
GKGa-Young Kim
Ga-Young Kim
JKJong Sei Kim
Jong Sei Kim
MJMini Jo
Mini Jo
HSHye Yoon Seol
Hye Yoon Seol
YCYoung Sang Cho
Young Sang Cho
IMIl Joon Moon
Il Joon Moon
Objectives. This study was conducted to investigate the electroacoustic characteristics of personal sound amplification products (PSAPs), to identify whether PSAPs provide adequate gain and output for three common hearing loss (HL) configurations, and to compare the benefits of a representative PSAP (RPSAP) and a conventional hearing aid (HA) for clinical hearing outcomes as a pilot study.Methods. The study comprised three phases: electroacoustic analysis, simulated real-ear measurements (REMs), and clinical hearing experiments. Electroacoustic analysis and simulated REMs were performed for three basic PSAPs (BeethoSOL, EarJJang, and Geniesori2) and three high-end PSAPs (Hearing Able, Olive Smart Ear, and SoriIn) using the Aurical Hearing Instrument Test box with a 2-mL coupler. Four electroacoustic characteristics (maximum output sound pressure level at 90 dB SPL, frequency range, equivalent input noise, and total harmonic distortion) were investigated. By simulated REMs, appropriate levels of the six PSAPs for three common HL configurations (mild-to-moderate high-frequency HL, moderate to moderately severe sloping HL, and moderate flat HL) were determined. Clinical experiments compared the performance of RPSAP to HA, both of which were fitted by audiologists using REMs. Clinical experiments were administered using functional gain, a word recognition test, and the Korean version of the Hearing in Noise Test in six participants with bilateral moderate sensorineural HL.Results. The two high-end devices met all tolerances. One basic and two high-end PSAPs showed appropriate levels for three common HL configurations. In the clinical experiments, the RPSAP showed better performance than unaided, but slightly worse than HA under all test conditions.Conclusion. Certain PSAPs met all specified tolerances for electroacoustic analysis and approximated prescriptive targets in well-controlled laboratory conditions. The pilot clinical experiments explored the possibility that the RPSAP could serve as a hearing assistive device for patients with moderate HL.

1 January 2022 in Journal of Korean Medical Science
Verified
Journal Article
Open access
PDF file
GKGa-Young Kim
Ga-Young Kim
SKSunyoung Kim
Sunyoung Kim
MJMini Jo
Mini Jo
HSHye Yoon Seol
Hye Yoon Seol
YCYoung Sang Cho
Young Sang Cho
IMIl Joon Moon
Il Joon Moon
Kim GY, et al. J Korean Med Sci. 2022 Mar;37(12):e94. https://doi.org/10.3346/jkms.2022.37.e94

1 January 2022 in Yonsei Medical Journal
Verified
Journal Article
Open access
PDF file
GKGa-Young Kim
Ga-Young Kim
YCYoung Sang Cho
Young Sang Cho
HBHye Min Byun
Hye Min Byun
HSHye Yoon Seol
Hye Yoon Seol
JLJihyun Lim
Jihyun Lim
IMIl Joon Moon
Il Joon Moon
Kim GY, et al. Yonsei Med J. 2022 Jun;63(6):570-577. https://doi.org/10.3349/ymj.2022.63.6.570

1 August 2021 in Clinical and Experimental Otorhinolaryngology
Verified
Journal Article
Open access
HSHye Yoon Seol
Hye Yoon Seol
GKGa-Young Kim
Ga-Young Kim
SKSoojin Kang
Soojin Kang
MJMini Jo
Mini Jo
UHUl Gyu Han
Ul Gyu Han
IMIl Joon Moon
Il Joon Moon

23 March 2022 in JMIR mHealth and uHealth
Verified
Journal Article
Open access
UHUl Gyu Han
Ul Gyu Han
JLJung-Yup Lee
Jung-Yup Lee
GKGa-Young Kim
Ga-Young Kim
MJMini Jo
Mini Jo
JLJaeseong Lee
Jaeseong Lee
IMIl Joon Moon
Il Joon Moon
Background: Hearing loss limits communication and social activity, and hearing aids (HAs) are an efficient rehabilitative option for improving oral communication and speech comprehension, as well as the psychosocial comfort of people with hearing loss. To overcome this problem, over-the-counter amplification devices including personal sound amplification products and wearable augmented reality devices (WARDs) have been introduced. Objective: This study aimed to evaluate the clinical effectiveness of WARDs for patients with mild to moderate hearing loss. Methods: A total of 40 patients (18 men and 22 women) with mild to moderate hearing loss were enrolled prospectively in this study. All participants were instructed to wear a WARD, Galaxy Buds Pro (Samsung Electronics), at least 4 hours a day for 2 weeks, for amplifying ambient sounds. Questionnaires including the Korean version of the abbreviated profile of hearing aid benefit (K-APHAB) and the Korean adaptation of the international outcome inventory for hearing aids (K-IOI-HA) were used to assess personal satisfaction in all participants. Audiologic tests, including sound field audiometry, sound field word recognition score (WRS), and the Korean version of hearing in noise test (K-HINT), were administered to 14 of 40 patients. The tests were performed under two conditions: unaided and aided with WARDs. Results: The mean age of the participants was 55.4 (SD 10.7) years. After 2 weeks of the field trial, participants demonstrated a benefit of WARDs on the K-APHAB. Scores of 3 subscales of ease of communication, reverberation, and background noise were improved significantly (P<.001). However, scores regarding aversiveness were worse under the aided condition (P<.001). K-IOI-HA findings indicated high user satisfaction after the 2-week field trial. On audiologic evaluation, the K-HINT did not show significant differences between unaided and aided conditions (P=.97). However, the hearing threshold on sound field audiometry (P=.001) and the WRS (P=.002) showed significant improvements under the aided condition. Conclusions: WARDs can be beneficial for patients with mild to moderate hearing loss as a cost-effective alternative to conventional hearing aids.