In order to study the restoring-force characteristics of precast concrete ring-lap beam-column joints, three precast concrete ring-lap beam-column joint specimens and one cast-in-place concrete beam-column joint specimen were designed and fabricated, and low-circumferential repeated loading tests were conducted. The results show that the bearing capacity of the ring-lap beam-column joint is higher than that of the cast-in-place beam-column joint, and with the increase in the lap length, the bearing capacity, ductility, and energy dissipation capacity of the ring-lap beam-column joint increase significantly, and the local damage is also mitigated. Based on the test results and the existing restoring-force model theory, a trifold restoring-force model is proposed for precast concrete ring-lap beam-column joints considering the effect of lap length. The proposed restoring-force model is consistent with the hysteresis curve of the assembled column, which indicates that the proposed restoring-force model can better reflect the influence of the lap length on the hysteresis characteristics, and can provide a reference for the structural elastic–plastic analysis and engineering application of the precast concrete ring-lap beam-column joint. The proposed restoring-force model can better reflect the influence of lap length on the hysteretic properties, which can provide a reference for the structural elastoplastic analysis and engineering application of this precast concrete ring-lap beam-column joint.
To study the effects of different parameters on the short-term stiffness and cracking load of precast laminated base slabs, static loading experiments were conducted on five base slabs to obtain their damage patterns, stiffness changes, and deflection. The parametric research on the base slab’s short-term stiffness and cracking load was followed by changing the parameters, such as the truss height, truss spacing, and base slab thickness, using finite element refinement modeling based on test cases. The results show: (1) the ductility, short-term stiffness, and cracking load of the base slab can be significantly improved by reducing the truss spacing, and its short-term stiffness and cracking load with the 300 mm truss spacing are relatively improved by comparing to the 60 mm one; (2) increasing the height of truss improves the short-term stiffness, cracking load, and ductility of base slab; however, the improvements decrease with the increase of truss height. With consideration of the cost and construction requirements, the proper truss spacing is provided.
1 January 2026 in Structural Durability & Health Monitoring
The large thickness of the common composite precast base slab leads to difficulties in construction through reinforcement installation and pipeline laying. To solve this problem, this paper proposes a lightweight ribbed base slab, reducing the base slab thickness to 30 mm compared to the ordinary precast base slab, adding concrete ribs to improve the mechanical properties of the base slab, and analyzing its damage pattern, stiffness change, and deflection deformation through static loading experiments. Based on the experimental conditions, the effect of concrete rib height, rib width, and top chord reinforcement diameter on the short-term stiffness of the base slab was analyzed in depth using finite element modeling. The research results show that setting concrete ribs in precast base slabs can improve the base slabs’ flexural stiffness, cracking load, and ductility. Compared with ordinary precast base slabs, the short-term stiffness of ribbed base slabs is increased by 3.19 times, and the cracking load is increased by 2.56 times, which is much larger than the construction load, meeting the requirement of no cracking during the construction stage. The construction can be completed without support over a certain span, thus speeding up the project’s progress and saving project costs. Increasing the rib height and width of the concrete and increasing the diameter of the top chord reinforcement can improve the short-term stiffness of the ribbed base slab, and in engineering applications, the choice of increasing the rib width to improve the short-term stiffness will have better mechanical properties and cost-effectiveness.