Ce Chen

Ce Chen


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 January 2023 in Buildings
Verified
Journal Article
Open access
PDF file
CCCe Chen
Ce Chen
ZXZhengrong Xue
Zhengrong Xue
YCYihu Chen
Yihu Chen
DLDan Lu
Dan Lu
WQWen Qin
Wen Qin
WYWei Yu
Wei Yu
In order to study the restoring-force characteristics of precast concrete ring-lap beam-column joints, three precast concrete ring-lap beam-column joint specimens and one cast-in-place concrete beam-column joint specimen were designed and fabricated, and low-circumferential repeated loading tests were conducted. The results show that the bearing capacity of the ring-lap beam-column joint is higher than that of the cast-in-place beam-column joint, and with the increase in the lap length, the bearing capacity, ductility, and energy dissipation capacity of the ring-lap beam-column joint increase significantly, and the local damage is also mitigated. Based on the test results and the existing restoring-force model theory, a trifold restoring-force model is proposed for precast concrete ring-lap beam-column joints considering the effect of lap length. The proposed restoring-force model is consistent with the hysteresis curve of the assembled column, which indicates that the proposed restoring-force model can better reflect the influence of the lap length on the hysteresis characteristics, and can provide a reference for the structural elastic–plastic analysis and engineering application of the precast concrete ring-lap beam-column joint. The proposed restoring-force model can better reflect the influence of lap length on the hysteretic properties, which can provide a reference for the structural elastoplastic analysis and engineering application of this precast concrete ring-lap beam-column joint.

19 October 2022 in Sustainability
Verified
Journal Article
Open access
PDF file
YCYihu Chen
Yihu Chen
YCYiyan Chen
Yiyan Chen
DLDan Lu
Dan Lu
CCCe Chen
Ce Chen
PLPengyuan Lu
Pengyuan Lu
JCJingyi Chen
Jingyi Chen
To study the effects of different parameters on the short-term stiffness and cracking load of precast laminated base slabs, static loading experiments were conducted on five base slabs to obtain their damage patterns, stiffness changes, and deflection. The parametric research on the base slab’s short-term stiffness and cracking load was followed by changing the parameters, such as the truss height, truss spacing, and base slab thickness, using finite element refinement modeling based on test cases. The results show: (1) the ductility, short-term stiffness, and cracking load of the base slab can be significantly improved by reducing the truss spacing, and its short-term stiffness and cracking load with the 300 mm truss spacing are relatively improved by comparing to the 60 mm one; (2) increasing the height of truss improves the short-term stiffness, cracking load, and ductility of base slab; however, the improvements decrease with the increase of truss height. With consideration of the cost and construction requirements, the proper truss spacing is provided.

10 September 2022 in Sustainability
Verified
Journal Article
Open access
PDF file
YWYanwei Wang
Yanwei Wang
QZQingxu Zhao
Qingxu Zhao
YLYuandi Li
Yuandi Li
CCCe Chen
Ce Chen
WZWanxu Zhu
Wanxu Zhu
The cable force of cable-stayed bridges may become abnormal during operation, so cable force anomaly detection is essential for evaluating the health of cables. The current methods for detecting cable force anomalies have poor resistance to temperature disturbances and are insensitive to abnormal cable force, making it challenging to detect minor cable force anomalies. Therefore, this work employs the short-time-average over long-time-average (STA/LTA) method to detect cable force anomalies. The characteristic function and key parameters of the STA/LTA method are optimized and tested by combining measured cable force data with cable force anomaly simulation. The results show that the STA/LTA method can effectively mitigate the interference of temperature in the detection of cable force anomalies and that it has good sensitivity to minor cable force anomalies. By examining detecting the measured cable force data of the Xiangjiang Bridge in Dongzhou, Hengyang, China, it is further verified that the STA/LTA method could effectively detect a cable force anomaly with a cable force deviation rate of higher than 1%.

18 April 2025 in Smart Construction
Verified
Journal Article
Closed access
YCYihu Chen
Yihu Chen
XYXingshuo Yang
Xingshuo Yang
JLJinchao Lin
Jinchao Lin
GXGuangxin Xie
Guangxin Xie
CCCe Chen
Ce Chen
YWYanwei Wang
Yanwei Wang
Grouted Bellows Connect Rebar (GBR) technology is critical for ensuring reliable connections in precast concrete components. The bond-slip behaviour, a core metric for assessing GBR connection perform...