Numerical flow simulations that analyze the turbulent flow characteristics within a turbopump are important for optimizing the efficiency of such machines. In the case of ventricular assist devices (VADs), turbulent flow characteristics must be also examined in order to improve hemocompatibility. Turbulence increases the shear stresses in the VAD flow, which can lead to an increased damage to the transported blood components. Therefore, an understanding of the turbulent flow patterns and their significance for the numerical blood damage prediction is particularly important for flow optimizations in VADs in order to identify and thus minimize flow regions where blood could be damaged due to high turbulent stresses. Nevertheless, the turbulence occurring in VADs and the local turbulent structures that lead to increased turbulent stresses have not yet been analyzed in detail in these machines. Therefore, this study aims to investigate the turbulence in an axial VAD in a comprehensive and double tracked way. First, the flow in an axial VAD was computed using the large‐eddy simulation method, and it was verified that the majority of the turbulence was directly resolved by the simulation. Then, the turbulent flow state of the VAD was quantified globally. For this purpose, a self‐designed evaluation method, the power loss analysis, was used. Subsequently, local flow regions and flow structures were identified where significant turbulent stresses prevail. It will be shown that the identified regions are universal and will also occur in other axial blood pumps as well, for example, in the HeartMate II.
13 June 2018 in The International Journal of Artificial Organs
Purpose: Numerical flow analysis (computational fluid dynamics) in combination with the prediction of blood damage is an important procedure to investigate the hemocompatibility of a blood pump, since blood trauma due to shear stresses remains a problem in these devices. Today, the numerical damage prediction is conducted using unsteady Reynolds-averaged Navier–Stokes simulations. Investigations with large eddy simulations are rarely being performed for blood pumps. Hence, the aim of the study is to examine the viscous shear stresses of a large eddy simulation in a blood pump and compare the results with an unsteady Reynolds-averaged Navier–Stokes simulation. Methods: The simulations were carried out at two operation points of a blood pump. The flow was simulated on a 100M element mesh for the large eddy simulation and a 20M element mesh for the unsteady Reynolds-averaged Navier-Stokes simulation. As a first step, the large eddy simulation was verified by analyzing internal dissipative losses within the pump. Then, the pump characteristics and mean and turbulent viscous shear stresses were compared between the two simulation methods. Results: The verification showed that the large eddy simulation is able to reproduce the significant portion of dissipative losses, which is a global indication that the equivalent viscous shear stresses are adequately resolved. The comparison with the unsteady Reynolds-averaged Navier–Stokes simulation revealed that the hydraulic parameters were in agreement, but differences for the shear stresses were found. Conclusion: The results show the potential of the large eddy simulation as a high-quality comparative case to check the suitability of a chosen Reynolds-averaged Navier–Stokes setup and turbulence model. Furthermore, the results lead to suggest that large eddy simulations are superior to unsteady Reynolds-averaged Navier–Stokes simulations when instantaneous stresses are applied for the blood damage prediction.
Ventricular assist devices (VADs) are implantable turbomachines that save and improve the lives of patients with severe heart failure. In the preclinical evaluation, a VAD design must be experimentally or numerically tested regarding its pump characteristics, primarily for its pressure buildup (pressure head ) since it must provide the cardiovascular system with a sufficient blood flow rate . Those pump characteristics are determined on a test bench. Here, a glycerol-water mixture is almost exclusively used as blood-analogous fluid, which should reflect the properties (density, viscosity) of blood as close as possible. However, glycerol water has some disadvantages, such as a higher density compared to real blood and a relatively high cost. Therefore, the study aimed to analyze six different blood analogous fluids to select the most suitable one in consideration of fluid handling, costs, and, most importantly, fluid properties (material and rheological). First, all fluids were mixed to achieve reference values of blood density and viscosity from the literature. Afterwards, the pump characteristics (pressure heads and efficiencies via the VAD) were experimentally and numerically determined and compared among each other and with literature values. Of all six investigated fluids, only the aqueous–polyethylene glycol 200 (PEG 200) solution matches exactly the desired blood properties, and the pump characteristics of this fluid are in the expected range for the analyzed operation point of the VAD. Another advantage is that the cost of the mixture is 35% lower compared to glycerol water. Additionally, we demonstrate that non-Newtonian flow behavior has little effect on the pump characteristics in our VAD.
28 November 2022 in Biomechanics and Modeling in Mechanobiology
The improvement and development of blood-contacting devices, such as mechanical circulatory support systems, is a life saving endeavor. These devices must be designed in such a way that they ensure the highest hemocompatibility. Therefore, in-silico trials (flow simulations) offer a quick and cost-effective way to analyze and optimize the hemocompatibility and performance of medical devices. In that regard, the prediction of blood trauma, such as hemolysis, is the key element to ensure the hemocompatibility of a device. But, despite decades of research related to numerical hemolysis models, their accuracy and reliability leaves much to be desired. This study proposes a novel optimization path, which is capable of improving existing models and aid in the development of future hemolysis models. First, flow simulations of three, turbulent blood flow test cases (capillary tube, FDA nozzle, FDA pump) were performed and hemolysis was numerically predicted by the widely-applied stress-based hemolysis models. Afterward, a multiple-objective particles swarm optimization (MOPSO) was performed to tie the physiological stresses of the simulated flow field to the measured hemolysis using an equivalent of over one million numerically determined hemolysis predictions. The results show that our optimization is capable of improving upon existing hemolysis models. However, it also unveils some deficiencies and limits of hemolysis prediction with stress-based models, which will need to be addressed in order to improve its reliability.
5 March 2021 in Cardiovascular Engineering and Technology
Purpose: Cardiovascular engineering includes flows with fluid-dynamical stresses as a parameter of interest. Mechanical stresses are high-risk factors for blood damage and can be assessed by computational fluid dynamics. By now, it is not described how to calculate an adequate scalar stress out of turbulent flow regimes when the whole share of turbulence is not resolved by the simulation method and how this impacts the stress calculation. Methods: We conducted direct numerical simulations (DNS) of test cases (a turbulent channel flow and the FDA nozzle) in order to access all scales of flow movement. After validation of both DNS with literature und experimental data using magnetic resonance imaging, the mechanical stress is calculated as a baseline. Afterwards, same flows are calculated using state-of-the-art turbulence models. The stresses are computed for every result using our definition of an equivalent scalar stress, which includes the influence from respective turbulence model, by using the parameter dissipation. Afterwards, the results are compared with the baseline data. Results: The results show a good agreement regarding the computed stress. Even when no turbulence is resolved by the simulation method, the results agree well with DNS data. When the influence of non-resolved motion is neglected in the stress calculation, it is underpredicted in all cases. Conclusion: With the used scalar stress formulation, it is possible to include information about the turbulence of the flow into the mechanical stress calculation even when the used simulation method does not resolve any turbulence.
Ventricular assist devices (VADs) are used to assist the heart function of patients with advanced heart failure. Computational fluid dynamics in VADs are widely applied in the development and optimization, for example, to evaluate blood damage. For these simulations, the pulsating operating conditions, in which the VAD operates, should be included accurately. Therefore, this study aims to evaluate the flow in a VAD by interacting with patient-specific cardiovascular systems of heart failure patients. A numeric method will be presented, which includes a patient-specific cardiovascular system model that is bidirectionally coupled with a three-dimensional (3D) flow simulation of the HeartMate 3. The cardiovascular system is represented by a lumped parameter model. Three heart failure patients are considered, based on clinical data from end-stage heart failure patients. Various parameters of the cardiovascular system and the VAD are analyzed, for example, flow rates, pressures, VAD heads, and efficiencies. A further important parameter is the blood damage potential of the VAD, which varies significantly among different patients. Moreover, the predicted blood damage fluctuates within a single heartbeat. The increase in blood damage is evaluated based on the operating conditions. Both, overload and especially partial load conditions during the pulsating operation result in elevated blood damage. Export