Muhammad Aniq Shazni Mohammad Haniff

Dr. Muhammad Aniq Shazni Mohammad Haniff

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2015 in Scientific Reports
Verified
Journal Article
Open access
MHMuhammad Aniq Shazni Mohammad Haniff
Muhammad Aniq Shazni Mohammad Haniff
SHSyed Muhammad Hafiz
Syed Muhammad Hafiz
KWKhairul Anuar Abd Wahid
Khairul Anuar Abd Wahid
ZEZulkarnain Endut
Zulkarnain Endut
HLHing Wah Lee
Hing Wah Lee
SRSaadah Abdul Rahman
Saadah Abdul Rahman
In this work, the piezoresistive effects of defective graphene used on a flexible pressure sensor are demonstrated. The graphene used was deposited at substrate temperatures of 750, 850 and 1000 °C using the hot-filament thermal chemical vapor deposition method in which the resultant graphene had different defect densities. Incorporation of the graphene as the sensing materials in sensor device showed that a linear variation in the resistance change with the applied gas pressure was obtained in the range of 0 to 50 kPa. The deposition temperature of the graphene deposited on copper foil using this technique was shown to be capable of tuning the sensitivity of the flexible graphene-based pressure sensor. We found that the sensor performance is strongly dominated by the defect density in the graphene, where graphene with the highest defect density deposited at 750 °C exhibited an almost four-fold sensitivity as compared to that deposited at 1000 °C. This effect is believed to have been contributed by the scattering of charge carriers in the graphene networks through various forms such as from the defects in the graphene lattice itself, tunneling between graphene islands and tunneling between defect-like structures.

2 April 2024 in Nanotechnology
Verified
Journal Article
Closed access
ARAini Ayunni Mohd Raub
Aini Ayunni Mohd Raub
RBRaihana Bahru
Raihana Bahru
MMMohd Ambri Mohamed
Mohd Ambri Mohamed
RLRhonira Latif
Rhonira Latif
MHMuhammad Aniq Shazni Mohammad Haniff
Muhammad Aniq Shazni Mohammad Haniff
JYJumril Yunas
Jumril Yunas
Nanostructured metal oxide semiconductors have emerged as promising nanoscale photocatalysts due to their excellent photosensitivity, chemical stability, non-toxicity, and biocompatibility. Enhancing the photocatalytic activity of metal oxide is critical in improving their efficiency in radical ion production upon optical exposure for various applications. Therefore, this review paper provides an in-depth analysis of the photocatalytic activity of nanostructured metal oxides, including the photocatalytic mechanism, factors affecting the photocatalytic efficiency, and approaches taken to boost the photocatalytic performance through structure or material modifications. This paper also highlights an overview of the recent applications and discusses the recent advancement of ZnO-based nanocomposite as a promising photocatalytic material for environmental remediation, energy conversion, and biomedical applications.

29 March 2021 in Materials
Verified
Journal Article
Open access
PDF file
USUmahwathy Sundararaju
Umahwathy Sundararaju
MHMuhammad Aniq Shazni Mohammad Haniff
Muhammad Aniq Shazni Mohammad Haniff
Pin Jern KerPin Jern Ker
Pin Jern Ker
P Susthitha MenonP Susthitha Menon
P Susthitha Menon
A photodetector converts optical signals to detectable electrical signals. Lately, self-powered photodetectors have been widely studied because of their advantages in device miniaturization and low power consumption, which make them preferable in various applications, especially those related to green technology and flexible electronics. Since self-powered photodetectors do not have an external power supply at zero bias, it is important to ensure that the built-in potential in the device produces a sufficiently thick depletion region that efficiently sweeps the carriers across the junction, resulting in detectable electrical signals even at very low-optical power signals. Therefore, two-dimensional (2D) materials are explored as an alternative to silicon-based active regions in the photodetector. In addition, plasmonic effects coupled with self-powered photodetectors will further enhance light absorption and scattering, which contribute to the improvement of the device’s photocurrent generation. Hence, this review focuses on the employment of 2D materials such as graphene and molybdenum disulfide (MoS2) with the insertion of hexagonal boron nitride (h-BN) and plasmonic nanoparticles. All these approaches have shown performance improvement of photodetectors for self-powering applications. A comprehensive analysis encompassing 2D material characterization, theoretical and numerical modelling, device physics, fabrication and characterization of photodetectors with graphene/MoS2 and graphene/h-BN/MoS2 heterostructures with plasmonic effect is presented with potential leads to new research opportunities.

24 April 2017 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
MHMuhammad Aniq Shazni Mohammad Haniff
Muhammad Aniq Shazni Mohammad Haniff
SHS. M. Hafiz
S. M. Hafiz
NHNay Ming Huang
Nay Ming Huang
SRS. A. Rahman
S. A. Rahman
KWK. A. A. Wahid
K. A. A. Wahid
IAI. A. Azid
I. A. Azid

7 August 2021 in Biosensors
Verified
Journal Article
Open access
PDF file
SNSiti Nur Ashakirin Binti Mohd Nashruddin
Siti Nur Ashakirin Binti Mohd Nashruddin
JAJaafar Abdullah
Jaafar Abdullah
MHMuhammad Aniq Shazni Mohammad Haniff
Muhammad Aniq Shazni Mohammad Haniff
MZMohd hazani Mat zaid
Mohd hazani Mat zaid
OCOoi Poh Choon
Ooi Poh Choon
MWMohd farhanulhakim Mohd razip wee
Mohd farhanulhakim Mohd razip wee
The electrochemical biosensor devices based on enzymes for monitoring biochemical substances are still considered attractive. We investigated the immobilization of glucose oxidase (GOx) on a new composite nanomaterial poly(3,4-ethylenedioxythiophene): polystyrene sulfonate (PEDOT:PSS)/titanium carbide,(Ti3C2)/graphene quantum dots(GQD) modified screen-printed carbon electrode (SPCE) for glucose sensing. The characterization and electrochemical behavior of PEDOT:PSS/Ti3C2/GQD towards the electrocatalytic oxidation of GOx was analyzed by FTIR, XPS, SEM, cyclic voltammetry (CV), and differential pulse voltammetry (DPV). This composite nanomaterial was found to tend to increase the electrochemical behavior and led to a higher peak current of 100.17 µA compared to 82.01 µA and 95.04 µA for PEDOT:PSS and PEDOT:PSS/Ti3C2 alone. Moreover, the detection results demonstrated that the fabricated biosensor had a linear voltammetry response in the glucose concentration range 0–500 µM with a relatively sensitivity of 21.64 µAmM−1cm−2 and a detection limit of 65 µM (S/N = 3), with good stability and selectivity. This finding could be useful as applicable guidance for the modification screen printed carbon (SPCE) electrodes focused on composite PEDOT:PSS/Ti3C2/GQD for efficient detection using an enzyme-based biosensor.

24 February 2023 in Nanomaterials
Verified
Journal Article
Open access
PDF file
SISiti Nor Ashikin Ismail
Siti Nor Ashikin Ismail
NNNazrul Anuar Nayan
Nazrul Anuar Nayan
MHMuhammad Aniq Shazni Mohammad Haniff
Muhammad Aniq Shazni Mohammad Haniff
RJRosmina Jaafar
Rosmina Jaafar
ZMZazilah May
Zazilah May
Flexible sensors have been extensively employed in wearable technologies for physiological monitoring given the technological advancement in recent years. Conventional sensors made of silicon or glass substrates may be limited by their rigid structures, bulkiness, and incapability for continuous monitoring of vital signs, such as blood pressure (BP). Two-dimensional (2D) nanomaterials have received considerable attention in the fabrication of flexible sensors due to their large surface-area-to-volume ratio, high electrical conductivity, cost effectiveness, flexibility, and light weight. This review discusses the transduction mechanisms, namely, piezoelectric, capacitive, piezoresistive, and triboelectric, of flexible sensors. Several 2D nanomaterials used as sensing elements for flexible BP sensors are reviewed in terms of their mechanisms, materials, and sensing performance. Previous works on wearable BP sensors are presented, including epidermal patches, electronic tattoos, and commercialized BP patches. Finally, the challenges and future outlook of this emerging technology are addressed for non-invasive and continuous BP monitoring.