Kazuhiro Matsui

Dr. Kazuhiro Matsui

Osaka University, Ōsaka, Japan
orcid

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 November 2014 in The International Journal of Cardiovascular Imaging
Verified
Journal Article
Closed access
PDF file
KMKazuhiro Matsui
Kazuhiro Matsui
HMHaruhiko Machida
Haruhiko Machida
TMTetsuya Mitsuhashi
Tetsuya Mitsuhashi
HOHisako Omori
Hisako Omori
TNTakashi Nakaoka
Takashi Nakaoka
EUEiko Ueno
Eiko Ueno

9 October 2024 in Frontiers in Bioengineering and Biotechnology
Verified
Journal Article
Open access
PDF file
TATetsuya Ando
Tetsuya Ando
KMKazuhiro Matsui
Kazuhiro Matsui
YOYuto Okamoto
Yuto Okamoto
KAKeita Atsuumi
Keita Atsuumi
KTKazuhiro Taniguchi
Kazuhiro Taniguchi
ANAtsushi Nishikawa
Atsushi Nishikawa
Introduction: Many studies have investigated the manipulation of a virtual upper arm using electromyogram (EMG); however, these studies primarily used a machine learning model or trigger control for this purpose. Furthermore, most of them could only display the constant motion of the virtual arm because the motion to be displayed was selected by pattern recognition or trigger control. In addition, these studies did not examine changes in the electromyographic signals after experiencing the virtual arm. By contrast, we propose a real-time, continuous, learning-free avatar that manipulates the virtual arm with electromyogram signals or physio-avatar EMG biofeedback (EB). The goal of the physio-avatar EB system is to induce physiological changes through experiential interactions.Methods: We explored the possibility of changing motor control strategies by applying the system to healthy individuals as a case study. An intervention method that provided an experience of a body different from one’s own was conducted on seven participants using a time-invariant calculation algorithm to determine the joint angles of the avatar. Control strategies for an indicator of the equilibrium point in the baseline and adaptation phases were determined to evaluate the physio-avatar EB intervention effect. The similarity of these BL and adaptation control strategies compared to those used during the washout period was assessed using the coefficient of determination. The accuracy and reliability of the virtual reality (VR) system were evaluated by comparison with existing studies and the required specs.Results and Discussion: Changes in motor control strategies due to the physio-avatar EB system were observed in four experiments, where the participants gradually returned to their pre-intervention control strategies. This result can be attributed to the aftereffects caused by error learning. This implies that the developed system influenced their motor control strategies. The number of EMG acquisition bits was 16 bits, and the sampling rate was 1,000 Hz. The refresh rate of the head-mounted display was 90 Hz, and its resolution was 1440×1600 for a single eye. Additionally, the simulation frame rate was 30 FPS. These values were adequate compared to existing studies and required specs. The essential contribution of this study is the development of an avatar that is controlled by a different method than has been used in previous studies and the demonstration of changes in a subject’s muscle activity after they experience an avatar. In the future, the clinical efficacy of the proposed system will be evaluated with actual patients.

1 January 2024 in Advanced Biomedical Engineering
Verified
Journal Article
Open access
PDF file
YSYuya Suzuki
Yuya Suzuki
KMKazuhiro Matsui
Kazuhiro Matsui
KAKeita Atsuumi
Keita Atsuumi
KTKazuhiro Taniguchi
Kazuhiro Taniguchi
HHHiroaki Hirai
Hiroaki Hirai
ANAtsushi Nishikawa
Atsushi Nishikawa
With recent advancements in human digital twin study, acquiring human neuromuscular characteristics has become a dire necessity. However, many of these studies use large equipment for imaging, such as computed tomography, and are not suitable for conducting clinical screening examinations. Evoked electromyography (eEMG) and manual muscle testing (MMT) are some of the simple clinical examination methods for acquiring human neuromuscular characteristics. The eEMG method is used to examine neural transmission functions. This method involves electrically stimulating nerves and analyzing the compound action potentials obtained from the muscles. However, it can only identify the time delay in the neuromuscular system. Alternatively, MMT is a simple testing method that can only obtain static muscle-force characteristics. Other methods to obtain muscle dynamic characteristics do not consider multiple muscle coordination. In this study, we developed a method to acquire the dynamics of human wrist-joint neuromuscular systems as a second-order and time delay system for clinical screening examinations. This method applies functional electrical stimulation (FES) to agonist-antagonist muscle pairs and achieve isometric force-sensing. The parameters of this dynamic system are indicators of the neuromuscular characteristics of this dynamic system. We confirmed the possibility of using these indicators for clinical examinations. The results suggest that the damping ratio is reproducible and can be applied to the clinical test, particularly for sarcopenia. However, further studies are needed to expand the frequency range of the input FES wave and examine the change of optimization method to fit the transfer function for system identification. In addition, a further study with a larger sample size is needed after strictly defining and recruiting the subject group.

29 September 2022 in Sensors
Verified
Journal Article
Open access
PDF file
KMKazuhiro Matsui
Kazuhiro Matsui
YSYuya Suzuki
Yuya Suzuki
KAKeita ATSUUMI
Keita ATSUUMI
MNMiwa Nagai
Miwa Nagai
SOShotaro Ohno
Shotaro Ohno
KTKazuhiro Taniguchi
Kazuhiro Taniguchi
(1) Background: A mouth-free interface is required for functional electrical stimulation (FES) in people with spinal cord injuries. We developed a novel system for clenching the human metacarpophalangeal (MP) joint using an earphone-type ear canal movement sensor. Experiments to control joint angle and joint stiffness were performed using the developed system. (2) Methods: The proposed FES used an equilibrium point control signal and stiffness control signal: electrical agonist–antagonist ratio and electrical agonist–antagonist sum. An angle sensor was used to acquire the joint angle, and system identification was utilized to measure joint stiffness using the external force of a robot arm. Each experiment included six and five subjects, respectively. (3) Results: While the joint angle could be controlled well by clenching with some hysteresis and delay in three subjects, it could not be controlled relatively well after hyperextension in the other subjects, which revealed a calibration problem and a change in the characteristics of the human MP joint caused by hyperextension. The joint stiffness increased with the clenching amplitude in five subjects. In addition, the results indicated that viscosity can be controlled. (4) Conclusions: The developed system can control joint angle and stiffness. In future research, we will develop a method to show that this system can control the equilibrium point and stiffness simultaneously.

21 May 2024 in PeerJ Computer Science
Verified
Journal Article
Open access
PDF file
YOYuto Okamoto
Yuto Okamoto
KMKazuhiro Matsui
Kazuhiro Matsui
TATetsuya Ando
Tetsuya Ando
KAKeita Atsuumi
Keita Atsuumi
KTKazuhiro Taniguchi
Kazuhiro Taniguchi
ANAtsushi Nishikawa
Atsushi Nishikawa
In recent years, due to the prevalence of virtual reality (VR) and human-computer interaction (HCI) research, along with the expectation that understanding the process of establishing sense of ownership, sense of agency, and limb heaviness (in this study, limb heaviness is replaced with comfort level) will contribute to the development of various medical rehabilitation, various studies have been actively conducted in these fields. Previous studies have indicated that each perceptual characteristics decrease in response to positive delay. However, it is still unclear how each perceptual characteristic changes in response to negative delay. Therefore, the purpose of this study was to deduce how changes occur in the perceptual characteristics when certain settings are manipulated using the avatar developed in this study. This study conducted experiments using an avatar system developed for this research that uses electromyography as the interface. Two separate experiments involved twelve participants: a preliminary experiment and a main experiment. As observed in the previous study, it was confirmed that each perceptual characteristics decreased for positive delay. In addition, the range of the preliminary experiment was insufficient for the purpose of this study, which was to confirm the perceptual characteristics for negative delay, thus confirming the validity of conducting this experiment. Meanwhile, the main experiment showed that the sense of ownership, sense of agency, and comfort level decreased gradually as delay time decreased, (i.e., this event is prior to action with intention, which could not be examined in the previous study). This suggests that control by the brain-machine interface is difficult to use when it is too fast. In addition, the distribution of the most strongly perceived settings in human perceptual characteristics was wider in regions with larger delays, suggesting this may lead to the evaluation of an internal model believed to exist in the human cerebellum. The avatar developed for this study may have the potential to create a new experimental paradigm for perceptual characteristics.

1 January 2000 in BUNSEKI KAGAKU
Verified
Journal Article
Open access
SNShigeaki Nishii
Shigeaki Nishii
YSYoshihiro Soya
Yoshihiro Soya
KMKazuhiro Matsui
Kazuhiro Matsui
TITakuya Ishibashi
Takuya Ishibashi
YKYoshihisa Kawamura
Yoshihisa Kawamura