(1) Background: A mouth-free interface is required for functional electrical stimulation (FES) in people with spinal cord injuries. We developed a novel system for clenching the human metacarpophalangeal (MP) joint using an earphone-type ear canal movement sensor. Experiments to control joint angle and joint stiffness were performed using the developed system. (2) Methods: The proposed FES used an equilibrium point control signal and stiffness control signal: electrical agonist–antagonist ratio and electrical agonist–antagonist sum. An angle sensor was used to acquire the joint angle, and system identification was utilized to measure joint stiffness using the external force of a robot arm. Each experiment included six and five subjects, respectively. (3) Results: While the joint angle could be controlled well by clenching with some hysteresis and delay in three subjects, it could not be controlled relatively well after hyperextension in the other subjects, which revealed a calibration problem and a change in the characteristics of the human MP joint caused by hyperextension. The joint stiffness increased with the clenching amplitude in five subjects. In addition, the results indicated that viscosity can be controlled. (4) Conclusions: The developed system can control joint angle and stiffness. In future research, we will develop a method to show that this system can control the equilibrium point and stiffness simultaneously.
1 January 2023 in Transactions of the JSME (in Japanese)
The nylon thread actuator, a type of super coiled polymer actuator, proposed by Haines et al. in 2014 has many useful advantages, including its relatively high power, lightweight, and low cost. Although the fabrication process seems simple, to fabricate such actuators, we must do so by hand because the finished products are not currently for sale. Thus, we are developing fully automated manufacturing equipment for overtwisted-type actuators using Ag-coated sewing machine nylon threads. In this study, we depict the details of a prototype machine and the basic specifications of conductive nylon thread actuators through experiments. This machine has three stepper motors. We found the maximum recommended drive speed of each spindle: the twist spindle with the drive is approximately 32.8 [rad/s] (313 [rpm]), the feeder speed is 37 [mm/min], and the winding speed is 61 [mm/min]. This condition provides steady overtwisted patterns with simply open-loop control, and the measured tension is approximately 20-30 [cN] during twisting, whereas it is approximately 40-50 [cN] during annealing. These processes run continuously for a single long thread; thus, the overall throughput is equal to the winding speed, which is determined by both the desired annealing tension and time.