Mohammad Amin Samieian

Dr. Mohammad Amin Samieian

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 September 2022 in Batteries
Verified
Journal Article
Open access
PDF file
MSMohammad Amin Samieian
Mohammad Amin Samieian
Alastair HalesAlastair Hales
Alastair Hales
YPYatish Patel
Yatish Patel
Battery models are one of the most important tools for understanding the behaviour of batteries. This is particularly important for the fast-moving electrical vehicle industry, where new battery chemistries are continually being developed. The main limiting factor on how fast battery models can be developed is the experimental technique used for collection of data required for model parametrisation. Currently, this is a very time-consuming process. In this paper, a fast novel parametrisation testing technique is presented. A model is then parametrised using this testing technique and compared to a model parametrised using current common testing techniques. This comparison is conducted using a WLTP (worldwide harmonised light vehicle test procedure) drive cycle. As part of the validation, the experiments were conducted at different temperatures and repeated using two different temperature control methods: climate chamber and a Peltier element temperature control method. The new technique introduced in this paper, named AMPP (accelerated model parametrisation procedure), is as good as GITT (galvanostatic intermittent titration technique) for parametrisation of ECMs (equivalent circuit models); however, it is 90% faster. When using experimental data from a climate chamber, a model parametrised using GITT was marginally better than AMPP; however, when using experimental data using conductive control, such as the ICP (isothermal control platform), a model parametrised using AMPP performed as well as GITT at 25 °C and better than GITT at 10 °C.

20 September 2022 in HardwareX
Verified
Journal Article
Open access
MSMohammad Amin Samieian
Mohammad Amin Samieian
CGCarlos E. Garcia
Carlos E. Garcia
LDLaura Bravo Diaz
Laura Bravo Diaz
AHAlastair Hales
Alastair Hales
YPYatish Patel
Yatish Patel
GOGregory J. Offer
Gregory J. Offer
Testing of lithium-ion batteries depends greatly on accurate temperature control in order to generate reliable experimental data. Reliable data is essential to parameterise and validate battery models, which are essential to speed up and reduce the cost of battery pack design for multiple applications. There are many methods to control the temperature of cells during testing, such as forced air convection, liquid cooling or conduction cooling using cooling plates. Depending on the size and number of cells, conduction cooling can be a complex and costly option. Although easier to implement, forced air cooling is not very effective and can introduce significant errors if used for battery model parametrisation. Existing commercially available immersion baths are not cost effective (∼£3320) and are usually too small to hold even one large pouch cell. Here, we describe an affordable but effective cooling method using immersion cooling. This bath is designed to house eight large lithium-ion pouch cells (300 mm × 350 mm), each immersed in a base oil cooling fluid (150L total volume). The total cost of this setup is only £1670. The rig is constructed using a heater, chilling unit, and a series of pumps. This immersion bath can maintain a temperature within 0.5 °C of the desired set point, it is operational within the temperature range 5–55 °C and has been validated at a temperature range of 25–45 °C.

1 April 2022 in SSRN Electronic Journal
Verified
Preprint
Open access
PDF file
MSMohammad Amin Samieian
Mohammad Amin Samieian
Alastair HalesAlastair Hales
Alastair Hales
GOGregory Offer
Gregory Offer
YPYatish Patel
Yatish Patel
Battery models are one of the most important tools for understanding the behaviour of batteries. This is particularly important for the fast-moving electrical vehicle industry, where new battery chemistries are continually being developed. The main limiting factor on how fast battery models can be developed is the experimental technique used for collection of data required for model parameterisation. Currently this is a very time-consuming process. In this paper, a fast novel parameterisation testing technique is presented. A model is then parameterised using this testing technique and compared, using a drive cycle, to a model parameterised using conventional testing techniques. The experiments are conducted at different temperatures and repeated using two different temperature control methods: forced-air convection and conduction. The new technique introduced in this paper, named AMPP (Accelerated model parametrisation procedure), is as good as GITT (Galvanostatic intermittent titration technique) for parametrisation of ECM’s (equivalent circuit model’s), however it is 90% faster. When using experimental data collected using forced-air convection, a model parameterised using GITT was marginally better than AMPP, however, when using experimental data using conductive control, a model parameterised using AMPP performed as well as GITT at 25°C and better than GITT at 10°C.

1 December 2022 in Experimental Mechanics
Verified
Journal Article
Open access
PDF file
MSMohammad Amin Samieian
Mohammad Amin Samieian
DCD. Cormie
D. Cormie
DSD. Smith
D. Smith
WWW. Wholey
W. Wholey
BBB.R.K. Blackman
B.R.K. Blackman
PHP.A. Hooper
P.A. Hooper
Background: The bending behaviour of laminated glass plays an important role in determining its overall response to blast loading. It is costly and difficult to characterise the bending behaviour by carrying out full-scale blast tests, therefore an alternative method is required. Objective: The objective of this study is to understand the response of laminated glass under high-rate bending in the laboratory at rates representative of blast loading. Methods: In this paper a novel testing method is presented in which laminated glass strips of 700 mm long by 60 mm wide are tested up to speeds of 10 m/s in the laboratory. The laminated glass is accelerated to speeds comparable to blast loading and then brought to rest at its edges to mimic impulsive blast loading conditions. Different interlayer thickness, impact speeds, and boundary conditions were explored. Additionally, modelling methods were used to study the flexural rigidity of post-cracked laminated glass. Results: From the experiments it was found that the interlayer thickness plays a key role in determining whether the dominant failure mechanism is de-bonding of interlayer from the glass or interlayer tearing. In addition, it was found that by allowing the frame to bend under loading, the laminated glass can carry greater loads without failure. Finally, an iterative method was used to quantify the flexural rigidity of post-cracked laminated glass depending on the speed of travel. This is a novel finding as it is usually assumed that laminated glass behaves like a membrane in the post-cracked phase of the response. Conclusion: In modelling and design of laminated glass structures under blast loading, post-crack flexural rigidity must be taken into account. Additionally, having novel frame designs to add further load bearing capacity to the framing members, plays a key role in reducing the load intensity on the laminated glass structure.