The purpose of a drinking water distribution system is to deliver drinking water to the consumer, preferably with the same quality as when it left the treatment plant. In this context, the maintenance of good microbiological quality is often referred to as biological stability, and the addition of sufficient chlorine residuals is regarded as one way to achieve this. The full-scale drinking water distribution system of Riga (Latvia) was investigated with respect to biological stability in chlorinated drinking water. Flow cytometric (FCM) intact cell concentrations, intracellular adenosine tri-phosphate (ATP), heterotrophic plate counts and residual chlorine measurements were performed to evaluate the drinking water quality and stability at 49 sampling points throughout the distribution network. Cell viability methods were compared and the importance of extracellular ATP measurements was examined as well. FCM intact cell concentrations varied from 5×103 cells mL−1 to 4.66×105 cells mL−1 in the network. While this parameter did not exceed 2.1×104 cells mL−1 in the effluent from any water treatment plant, 50% of all the network samples contained more than 1.06×105 cells mL−1. This indisputably demonstrates biological instability in this particular drinking water distribution system, which was ascribed to a loss of disinfectant residuals and concomitant bacterial growth. The study highlights the potential of using cultivation-independent methods for the assessment of chlorinated water samples. In addition, it underlines the complexity of full-scale drinking water distribution systems, and the resulting challenges to establish the causes of biological instability.
1 June 2007 in Applied and Environmental Microbiology
The effect of phosphorus addition on survival of Escherichia coli in an experimental drinking water distribution system was investigated. Higher phosphorus concentrations prolonged the survival of culturable E. coli in water and biofilms. Although phosphorus addition did not affect viable but not culturable (VBNC) E. coli in biofilms, these structures could act as a reservoir of VBNC forms of E. coli in drinking water distribution systems.
Effect of microbially available phosphorus (MAP) on biofilm development in drinking water systems was investigated at the pilot-scale experiments over 3 years. Completely mixed biofilm reactors Propella® (water detention time 24 h, flow rate 0.25 m s−1, PVC pipe coupons) were used as water distribution network models. Four experimental runs were carried out with water containing different levels of phosphorus which was limiting nutrient for bacterial growth. Positive correlation between MAP in the inlet water and heterotrophic plate count (correlation coefficient 0.95) in biofilm, as well as for the total bacteria number (correlation coefficient 0.71), was observed. However, our experiments showed that removal of phosphorus down to very low levels (below detection limits of chemical method and MAP < 1 μg L−1) was not an efficient strategy to eliminate bacterial regrowth and biofilm formation (<51,00,000 cells/cm2) in drinking water supply systems.
By using industrial aluminium recycling waste, recycled silicate glass from outworn fluorescence lamp recycling plant, calcined kaolinite clay supplemented with alkali activator with different silicate modulus the new type of porous material for biotechnologic processes without the need for additional equipment for pH control was researched. This controlled-release system contains an alkali activated matrix in which NaOH crystals are encased. In this study ability to release NaOH per time in water according to material composition and structure were investigated. Three alkaline activated materials AAM 7.5, 10 and 12.5, with different alkali activator content were characterized.
Chemical precipitation in combination with biological treatment is a commonly used method for removal of turbidity and dissolved organic carbon (DOC) from drinking water. DOC is largely removed during biological treatment, which includes ozonation and filtration through a biologically active carbon (BAC) filter. Ozone converts humic substances into a biologically labile form that is mineralised by bacteria living in the following BAC filter. This study shows that this approach is often not efficient for removal of DOC from waters with a high amount of humic substances. During chemical treatment, the microbiologically available phosphorus is very efficiently removed, which results in shortages of phosphorus needed for bacteria to mineralise carbon in BAC filters. To enhance removal of DOC by biological treatment, addition of phosphorus prior to the BAC filters should be considered.
3 September 2012 in Drinking Water Engineering and Science
The effect of pipe fittings (mainly T-pieces) on particle accumulation in drinking water distribution networks were shown in this work. The online measurements of flow and turbidity for cast iron, polyethylene and polyvinyl chloride pipe sections were linked with analysis of pipe geometry. Up to 0.29 kg of the total amount mobilized in T-pieces ranging from DN 100/100–DN 250/250. The accumulated amount of particles in fittings was defined as J and introduced into the existing turbidity model PODDS (prediction of discoloration in distribution systems) proposed by Boxall et al. (2001) which describes the erosion of particles leading to discoloration events in drinking water network viz sections of straight pipes. However, this work does not interpret mobilization of particles in pipe fittings which have been considered in this article. T-pieces were the object of this study and depending of the diameter or daily flow velocity, the coefficient J varied from 1.16 to 8.02. The study showed that pipe fittings act as catchment areas for particle accumulation in drinking water networks.