Talis Juhna

Dr. Talis Juhna

Water Research Laboratory, Riga Technical University, Riga, Latvia
orcid

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 May 2014 in PLOS ONE
Verified
Journal Article
Open access
PDF file
ANAlina Nescerecka
Alina Nescerecka
JRJanis Rubulis
Janis Rubulis
MVMarius Vital
Marius Vital
Talis JuhnaTalis Juhna
Talis Juhna
FHFrederik Hammes
Frederik Hammes
The purpose of a drinking water distribution system is to deliver drinking water to the consumer, preferably with the same quality as when it left the treatment plant. In this context, the maintenance of good microbiological quality is often referred to as biological stability, and the addition of sufficient chlorine residuals is regarded as one way to achieve this. The full-scale drinking water distribution system of Riga (Latvia) was investigated with respect to biological stability in chlorinated drinking water. Flow cytometric (FCM) intact cell concentrations, intracellular adenosine tri-phosphate (ATP), heterotrophic plate counts and residual chlorine measurements were performed to evaluate the drinking water quality and stability at 49 sampling points throughout the distribution network. Cell viability methods were compared and the importance of extracellular ATP measurements was examined as well. FCM intact cell concentrations varied from 5×103 cells mL−1 to 4.66×105 cells mL−1 in the network. While this parameter did not exceed 2.1×104 cells mL−1 in the effluent from any water treatment plant, 50% of all the network samples contained more than 1.06×105 cells mL−1. This indisputably demonstrates biological instability in this particular drinking water distribution system, which was ascribed to a loss of disinfectant residuals and concomitant bacterial growth. The study highlights the potential of using cultivation-independent methods for the assessment of chlorinated water samples. In addition, it underlines the complexity of full-scale drinking water distribution systems, and the resulting challenges to establish the causes of biological instability.

1 May 2018 in Water Research
Verified
Journal Article
Closed access
ANAlina Nescerecka
Alina Nescerecka
Talis JuhnaTalis Juhna
Talis Juhna
FHFrederik Hammes
Frederik Hammes


15 November 2007 in Applied and Environmental Microbiology
Verified
Journal Article
Closed access
Talis JuhnaTalis Juhna
Talis Juhna
DBD. Birzniece
D. Birzniece
SLSimona Larsson
Simona Larsson
DZD. Zulenkovs
D. Zulenkovs
ASA. Sharipo
A. Sharipo
Charles William KeevilCharles William Keevil
Charles William Keevil
Fluorescence in situ hybridization (FISH) was used for direct detection of Escherichia coli on pipe surfaces and coupons in drinking water distribution networks. Old cast iron main pipes were removed from water distribution networks in France, England, Portugal, and Latvia, and E. coli was analyzed in the biofilm. In addition, 44 flat coupons made of cast iron, polyvinyl chloride, or stainless steel were placed into and continuously exposed to water on 15 locations of 6 distribution networks in France and Latvia and examined after 1 to 6 months exposure to the drinking water. In order to increase the signal intensity, a peptide nucleic acid (PNA) 15-mer probe was used in the FISH screening for the presence or absence of E. coli on the surface of pipes and coupons, thus reducing occasional problems of autofluorescence and low fluorescence of the labeled bacteria. For comparison, cells were removed from the surfaces and examined with culture-based or enzymatic (detection of β- d -glucuronidase) methods. An additional verification was made by using PCR. Culture method indicated presence of E. coli in one of five pipes, whereas all pipes were positive with the FISH methods. E. coli was detected in 56% of the coupons using PNA FISH, but no E. coli was detected using culture or enzymatic methods. PCR analyses confirmed the presence of E. coli in samples that were negative according to culture-based and enzymatic methods. The viability of E. coli cells in the samples was demonstrated by the cell elongation after resuscitation in low-nutrient medium supplemented with pipemidic acid, suggesting that the cells were present in an active but nonculturable state, unable to grow on agar media. E. coli contributed to ca. 0.001 to 0.1% of the total bacterial number in the samples. The presence and number of E. coli did not correlate with any of physical and/or chemical characteristic of the drinking water (e.g., temperature, chlorine, or biodegradable organic matter concentration). We show here that E. coli is present in the biofilms of drinking water networks in Europe. Some of the cells are metabolically active but are often not detected due to limitations of traditionally used culture-based methods, indicating that biofilm should be considered as a reservoir that must be investigated further in order to evaluate the risk for human health.

1 November 2009 in Desalination
Verified
Journal Article
Closed access
LML. Mezule
L. Mezule
STS. Tsyfansky
S. Tsyfansky
VYV. Yakushevich
V. Yakushevich
Talis JuhnaTalis Juhna
Talis Juhna

1 September 2016 in Water Research
Verified
Journal Article
Closed access
ANAlina Nescerecka
Alina Nescerecka
Talis JuhnaTalis Juhna
Talis Juhna
FHFrederik Hammes
Frederik Hammes