Ning Lang

Dr. Ning Lang


Research Focus & Metrics

Academic Career Length

34Years (1993-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 May 2021 in European Radiology
Verified
Journal Article
Closed access
PDF file
YLYuan Li
Yuan Li
YZYang Zhang
Yang Zhang
EZEnlong Zhang
Enlong Zhang
YCYongye Chen
Yongye Chen
QWQizheng Wang
Qizheng Wang
MSMin-Ying Su
Min-Ying Su

8 March 2015 in European Spine Journal
Verified
Journal Article
Closed access
PDF file
NLNing Lang
Ning Lang
LSLydia Su
Lydia Su
HYHon J. Yu
Hon J. Yu
HYHui-Shu Yuan
Hui-Shu Yuan

12 May 2021 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Closed access
PDF file
JLJianfang Liu
Jianfang Liu
PZPiaoe Zeng
Piaoe Zeng
WGWei Guo
Wei Guo
CWChunjie Wang
Chunjie Wang
YGYayuan Geng
Yayuan Geng
HYHui-Shu Yuan
Hui-Shu Yuan

29 June 2023 in European Radiology
Verified
Journal Article
Open access
PDF file
QWQizheng Wang
Qizheng Wang
WZWeili Zhao
Weili Zhao
XXXiaoying Xing
Xiaoying Xing
YWYing Wang
Ying Wang
PXPeijin Xin
Peijin Xin
NLNing Lang
Ning Lang
Objectives: To evaluate the image quality and diagnostic performance of AI-assisted compressed sensing (ACS) accelerated two-dimensional fast spin-echo MRI compared with standard parallel imaging (PI) in clinical 3.0T rapid knee scans. Methods: This prospective study enrolled 130 consecutive participants between March and September 2022. The MRI scan procedure included one 8.0-min PI protocol and two ACS protocols (3.5 min and 2.0 min). Quantitative image quality assessments were performed by evaluating edge rise distance (ERD) and signal-to-noise ratio (SNR). Shapiro-Wilk tests were performed and investigated by the Friedman test and post hoc analyses. Three radiologists independently evaluated structural disorders for each participant. Fleiss κ analysis was used to compare inter-reader and inter-protocol agreements. The diagnostic performance of each protocol was investigated and compared by DeLong’s test. The threshold for statistical significance was set at p  < 0.05. Results: A total of 150 knee MRI examinations constituted the study cohort. For the quantitative assessment of four conventional sequences with ACS protocols, SNR improved significantly (p < 0.001), and ERD was significantly reduced or equivalent to the PI protocol. For the abnormality evaluated, the intraclass correlation coefficient ranged from moderate to substantial between readers (κ = 0.75–0.98) and between protocols (κ = 0.73–0.98). For meniscal tears, cruciate ligament tears, and cartilage defects, the diagnostic performance of ACS protocols was considered equivalent to PI protocol (Delong test, p > 0.05). Conclusions: Compared with the conventional PI acquisition, the novel ACS protocol demonstrated superior image quality and was feasible for achieving equivalent detection of structural abnormalities while reducing acquisition time by half. Clinical relevance statement: Artificial intelligence–assisted compressed sensing (ACS) providing excellent quality and a 75% reduction in scanning time presents significant clinical advantages in improving the efficiency and accessibility of knee MRI for more patients. Key Points: • The prospective multi-reader study showed no difference in diagnostic performance between parallel imaging and AI-assisted compression sensing (ACS) was found. • Reduced scan time, sharper delineation, and less noise with ACS reconstruction. • Improved efficiency of the clinical knee MRI examination by the ACS acceleration.

30 May 2023 in Cancers
Verified
Journal Article
Open access
PDF file
KLKe Liu
Ke Liu
SQSiyuan Qin
Siyuan Qin
JNJinlai Ning
Jinlai Ning
PXPeijin Xin
Peijin Xin
Qizheng WangQizheng Wang
Qizheng Wang
NLNing Lang
Ning Lang
We aim to investigate the feasibility and evaluate the performance of a ResNet-50 convolutional neural network (CNN) based on magnetic resonance imaging (MRI) in predicting primary tumor sites in spinal metastases. Conventional sequences (T1-weighted, T2-weighted, and fat-suppressed T2-weighted sequences) MRIs of spinal metastases patients confirmed by pathology from August 2006 to August 2019 were retrospectively analyzed. Patients were partitioned into non-overlapping sets of 90% for training and 10% for testing. A deep learning model using ResNet-50 CNN was trained to classify primary tumor sites. Top-1 accuracy, precision, sensitivity, area under the curve for the receiver-operating characteristic (AUC-ROC), and F1 score were considered as the evaluation metrics. A total of 295 spinal metastases patients (mean age ± standard deviation, 59.9 years ± 10.9; 154 men) were evaluated. Included metastases originated from lung cancer (n = 142), kidney cancer (n = 50), mammary cancer (n = 41), thyroid cancer (n = 34), and prostate cancer (n = 28). For 5-class classification, AUC-ROC and top-1 accuracy were 0.77 and 52.97%, respectively. Additionally, AUC-ROC for different sequence subsets ranged between 0.70 (for T2-weighted) and 0.74 (for fat-suppressed T2-weighted). Our developed ResNet-50 CNN model for predicting primary tumor sites in spinal metastases at MRI has the potential to help prioritize the examinations and treatments in case of unknown primary for radiologists and oncologists.

1 June 1993 in Inflammopharmacology
Verified
Journal Article
Closed access
PDF file
PSPredrag Sikiric
Predrag Sikiric
KGK. Gyires
K. Gyires
SSSven Seiwerth
Sven Seiwerth
ZGZ. GrabarevlĆ
Z. GrabarevlĆ
RRR. RuČman
R. RuČman
MBM. Bura
M. Bura