RuLu OuYang

Ms. RuLu OuYang


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 April 2023 in Membranes
Verified
Journal Article
Open access
PDF file
Chun-Hai WeiChun-Hai Wei
Chun-Hai Wei
YLYequan Lao
Yequan Lao
RORuLu OuYang
RuLu OuYang
GZGUORUI ZHANG
GUORUI ZHANG
GHGuijing Huang
Guijing Huang
HZHong Zhou
Hong Zhou
Different commercial reverse osmosis (RO) membranes from Vontron and DuPont Filmtec were evaluated for textile dyeing and finishing wastewater (TDFW) reuse in China. All six tested RO membranes produced qualified permeate meeting TDFW reuse standards at a water recovery ratio (WRR) of 70% in single batch tests. The rapid decline of apparent specific flux at WRR over 50% was mainly ascribed to feed osmotic pressure increase caused by concentrating effects. Multiple batch tests using Vontron HOR and DuPont Filmtec BW RO membranes with comparable permeability and selectivity demonstrated the reproducibility and showed low fouling development. The occurrence of carbonate scaling on both RO membranes was identified by scanning electron microscopy and energy disperse spectroscopy. No obvious organic fouling was detected on both RO membranes by attenuated total reflectance Fourier transform infrared spectrometry. From the orthogonal tests, with an integrated RO membrane performance index (i.e., 25% rejection ratio of total organic carbon + 25% rejection ratio of conductivity + 50% flux ratio of final to initial) as a target, the optimal parameters were determined as WRR of 60%, cross-flow velocity (CFV) of 1.0 m/s, temperature (T) of 20 °C for both RO membranes, while trans-membrane pressures (TMP) of 2 and 4 MPa were optimal for Vontron HOR RO membrane and DuPont Filmtec BW RO membrane, respectively. Both RO membranes with the optimal parameters produced good permeate quality for TDFW reuse and kept a high flux ratio of final to initial, demonstrating the effectiveness of the orthogonal tests.

21 August 2022 in Membranes
Verified
Journal Article
Open access
PDF file
RORuLu OuYang
RuLu OuYang
BHBin Huang
Bin Huang
Chun-Hai WeiChun-Hai Wei
Chun-Hai Wei
HRHongwei Rong
Hongwei Rong
HYHuarong Yu
Huarong Yu
XHXia Huang
Xia Huang
It is of great importance to quantitatively characterize feed fouling potential for the effective and efficient prevention and control of reverse osmosis membrane fouling. A gradient filtration method with microfiltration (MF 0.45 μm) → ultrafiltration (UF 100 kDa) → nanofiltration (NF 300 Da) was proposed to extract the cake layer fouling index, I, of different feed foulants in this study. MF, UF, and NF showed high rejection of model suspended solids (kaolin), colloids (sodium alginate and bovine serum albumin), and dissolved organic matters (humic acid) during constant-pressure individual filtration tests, where the cake layer was the dominant fouling mechanism, with I showing a good linear positive correlation with the foulant concentration. MF → UF → NF gradient filtration tests of synthetic wastewater (i.e., model mixture) showed that combined models were more effective than single models to analyze membrane fouling mechanisms. For each membrane of gradient filtration, I showed a positive correlation with the targeted foulant concentration. Therefore, a quantitative assessment method based on MF → UF → NF gradient filtration, the correlation of combined fouling models, and the calculation of I would be useful for characterizing the fouling potentials of different foulants. This method was further successfully applied for characterizing the fouling potential of real wastewater (i.e., sludge supernatant from a membrane bioreactor treating dyeing and finishing wastewater).

4 January 2026 in Membranes
Verified
Journal Article
Open access
PDF file
ZWZhengwei Wang
Zhengwei Wang
RORuLu OuYang
RuLu OuYang
GZGUORUI ZHANG
GUORUI ZHANG
Chun-Hai WeiChun-Hai Wei
Chun-Hai Wei
SJShiming Ji
Shiming Ji
HRHongwei Rong
Hongwei Rong
Reverse osmosis (RO) is the key process for textile dyeing wastewater reuse applications. Membrane fouling reduces both permeability and rejection capability, negatively affecting the technological economy of RO process. Membrane cleaning is critical to recovery of the permeability of fouled RO membranes. Based on multi-batch filtration and cleaning experiments, this study systematically evaluated the RO membrane fouling potential of pre-treated textile dyeing wastewater by a membrane bioreactor and the recovery performance of fouled RO membranes after different cleaning methods. A significant decline (more than 15%) in RO membrane permeability occurred after RO membrane permeate production of 625 L/m2 at a water recovery ratio of 60%. Protein-like substances and soluble microbial products were identified as the primary organic foulants via three-dimensional fluorescence excitation-emission matrix spectrometry (3D-FEEM). The single forward flushing with either pure water, acid, alkaline, or sodium hypochlorite solutions with a low active chlorine concentration showed very limited recovery of fouled RO membrane permeability. The combined forward flushing with acid followed by alkaline solutions restored fouled membrane permeability by up to 87% of a new RO membrane. The addition of pure water backwashing at a transmembrane pressure (TMP) of 0.5 MPa after both acid and alkaline solutions combined forward flushing restored fouled membrane permeability by up to 97% of a new RO membrane but deteriorated the rejection capability of the RO membrane. The backwashing parameters were further optimized at a TMP of 0.125 MPa and crossflow velocity (CFV) of 0.5 m/s, achieving fouled RO membrane permeability by up to 96% of a new RO membrane, and there were no negative effects on the rejection capability of the RO membrane. Alkaline forward flushing followed by pure water backwashing was the dominant contributor for fouled RO membrane permeability recovery. A preliminary economic analysis showed that the total chemical cost per RO production was 0.763 CNY/m3 and could be further reduced via removing acid cleaning and replacing combined alkaline flushing and pure water backwashing with alkaline backwashing.

17 November 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
ZWZhengwei Wang
Zhengwei Wang
RORuLu OuYang
RuLu OuYang
GZGUORUI ZHANG
GUORUI ZHANG
Chun-Hai WeiChun-Hai Wei
Chun-Hai Wei
SJShiming Ji
Shiming Ji
HRHongwei Rong
Hongwei Rong
Based on multi-batch filtration and cleaning experiments, this study systematically evaluated the fouling potential of pre-treated textile dyeing wastewater by membrane bioreactor on reverse osmosis (RO) membranes and the recovery performance of fouled RO membranes after different cleaning methods. After a permeate production of 625 L/m², continuous foulants accumulation resulted in a significant decline in RO membrane permeability. Protein-like substances and sol-uble microbial products were identified as the primary organic foulants via three-dimensional fluorescence excitation-emission matrix spectrometry (3D-FEEM). The single forward flushing with pure water, acid solution (pH 3.5), alkaline solution (pH 10.5), and sodium hypochlorite with low effective chlorine concentration (1-2 mg/L) showed very limited recovery of fouled RO membrane permeability. The combined forward flushing with acid solution (pH 2) followed by alkaline solution (pH 11.5) restored fouled membrane permeability up to 87% of new RO mem-brane. The addition of pure water backwashing at transmembrane pressure of 0.5 MPa after both acid and alkaline combined forward flushing restored fouled membrane permeability up to 97% of new RO membrane but deteriorated the rejection capacity of RO membrane. The backwashing parameters were further optimized as transmembrane pressure of 0.5 MPa and crossflow veloci-ty of 0.5 m/s, achieving fouled membrane permeability up to 96% of new RO membrane and no negative effects on the rejection capacity of RO membrane. Therefore, the combined cleaning of acid forward flushing → pure water backwashing → alkaline forward flushing → pure water backwashing was proposed for RO membrane cleaning from textile dyeing wastewater reuse application.