The Ocular Comfort Index (OCI) assesses ocular surface irritation and grades the severity of dry eye disease. This study sought to adapt the OCI questionnaire into Spanish, and then to assess the psychometric performance and validity of the new adapted version (OCI-versión española, OCIVE). The questionnaire was translated, back translated, and then cross-culturally adapted for use with Spanish-speaking individuals. The OCIVE was completed by 450 participants, including 53 subjects that were diagnosed with dry eye disease. Through a Rasch analysis, the psychometric properties of item fit, targeting, person separation, reliability, and differential item functioning (DIF) were assessed. To test the convergent validity, we examined the correlation between the OCIVE and the Computer Vision Symptom Scale (CVSS17). Validity was tested in a subgroup of participants with and without dry eye, and test-retest repeatability was determined in a subset of 151 individuals. We also compared, via DIF, the performance of the OCIVE with that of the original OCI. Our Rasch analysis revealed a good model fit, high accuracy, good targeting, unidimensionality, and no DIF according to gender. The validity and repeatability were good. The OCIVE shows comparable psychometric properties to the original English version, making it a valid tool for measuring dry eye symptoms in Spanish adults.
17 March 2024 in Clinical and Experimental Optometry
Clinical relevance: Multidiagnostic systems have recently appeared on the market. Knowledge of the repeatability and validity of any instrument is mandatory before its introduction in clinical practice. Background: The aim of this work is to examine the intrasession repeatability of anterior pole measurements provided by the multidiagnostic device Wave Analyzer Medica 700 (WAM700) and agreement with Pentacam measurements in normal eyes. Methods: In the right eyes of 113 participants, three repeat measurements of central keratometry, central corneal thickness, anterior chamber depth and corneal eccentricity were made with the WAM700 and Pentacam in random order. Intrasession repeatability and agreement were determined. Results: Employing WAM700, intrasession repeatability for keratometry, central corneal thickness and anterior chamber depth was good (ICCs >= 0.992; CV 0.48-0.98%), yet worse than the values obtained for the Pentacam (ICCs >= 0.998; CV 0-0.33%). WAM700 showed excellent intrasession repeatability when used to measure the anterior chamber depth (Sw 0.03 mm). However, the repeatability of this device was inferior for central corneal thickness (Sw 4.24 mu m) and keratometry measurements (Sw < 0.21 D) and was poor for corneal eccentricity (Sw 0.07; ICC 0.908; CV 14.58%). Agreement between WAM700 and Pentacam showed a high ICC for the keratometry measurements, central corneal thickness and anterior chamber depth (>0.972) but lower for corneal eccentricity (ICC 0.762). Conclusions: In healthy eyes, the WAM700 multidiagnostic device showed good intrasession repeatability for keratometry, central corneal thickness and anterior chamber depth measurements. Agreement between WAM700 and Pentacam was good for the anterior chamber depth measurement. However, these instruments cannot be considered interchangeable for keratometry, central corneal thickness and eccentricity readings.