Wojciech Kowalczyk

Prof. Wojciech Kowalczyk

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 June 2007 in Experiments in Fluids
Verified
Journal Article
Closed access
PDF file
WKWojciech Kowalczyk
Wojciech Kowalczyk
BZBogumila Ewelina Zima
Bogumila Ewelina Zima
ADAntonio Delgado
Antonio Delgado

1 January 2012 in Biomedical Engineering / Biomedizinische Technik
Verified
Journal Article
Closed access
DWDaniel Wendt
Daniel Wendt
SSSebastian Stühle
Sebastian Stühle
JPJarowit Adam Piotrowski
Jarowit Adam Piotrowski
HWHermann Wendt
Hermann Wendt
MTMatthias Thielmann
Matthias Thielmann
WKWojciech Kowalczyk
Wojciech Kowalczyk
The aim of the present study was to evaluate and compare the in vitro and flow dynamics of the Magna (MB) and the Magna Ease aortic valve bioprosthesis (MEB) within the ascending aorta. A 2D-particle-image-velocimetry (2D-PIV) study was performed to compare the flow dynamics induced by each pericardial Carpentier-Edwards Magna and Magna Ease aortic valve prosthesis in the aortic flow field directly behind the valve. Both prostheses (diameter 23 mm) were placed inside an artificial aorta under pulsatile flow conditions (70 Hz and 70 ml stroke volume). The flow field was evaluated according to velocity, shear strength, and vorticity. Both prostheses showed a jet flow type profile with a maximum velocity of 0.97±0.09 m/s for MB and 0.83±1.8 m/s for MEB. Flow fields of both valves were similar in acceleration, peak flow deceleration and leakage phase. Maximum shear strength was 20,285±11,774 l/s2 for MB and 17,006±8453 l/s2 for MEB. Vorticity was nearly similar for counterclockwise and clockwise rotation in both prostheses, but slightly higher with MB (251±41 l/s and -250±39 l/s vs. 225±48 l/s and -232±48 l/s). The point-of-interest (POI)-analysis revealed a higher velocity for left-sided aortic wall compared to right-sided at MB (0.12±0.09 m/s vs. 0.18±0.10 m/s, p<0.001), but was consistent at MEB (0.09±0.05 m/s vs. 0.08±0.04 m/s, p=0.508), respectively. Velocity, shear strength and vorticity in an in vitro test set-up are lower with MEB compared to MB, thus resulting in improved flow dynamics with a similar flow field, which might have a positive influence on blood rheology and potential valve degeneration.

6 October 2022 in Bioengineering
Verified
Journal Article
Open access
PDF file
Aroj BhattaraiAroj Bhattarai
Aroj Bhattarai
CMCharlotte Anabell May
Charlotte Anabell May
Manfred StaatManfred Staat
Manfred Staat
WKWojciech Kowalczyk
Wojciech Kowalczyk
TTThanh Ngoc Tran
Thanh Ngoc Tran
The mechanical behavior of the large intestine beyond the ultimate stress has never been investigated. Stretching beyond the ultimate stress may drastically impair the tissue microstructure, which consequently weakens its healthy state functions of absorption, temporary storage, and transportation for defecation. Due to closely similar microstructure and function with humans, biaxial tensile experiments on the porcine large intestine have been performed in this study. In this paper, we report hyperelastic characterization of the large intestine based on experiments in 102 specimens. We also report the theoretical analysis of the experimental results, including an exponential damage evolution function. The fracture energies and the threshold stresses are set as damage material parameters for the longitudinal muscular, the circumferential muscular and the submucosal collagenous layers. A biaxial tensile simulation of a linear brick element has been performed to validate the applicability of the estimated material parameters. The model successfully simulates the biomechanical response of the large intestine under physiological and non-physiological loads.

3 March 2019 in Minimally Invasive Therapy & Allied Technologies
Verified
Journal Article
Closed access
PMPhilipp Marx
Philipp Marx
WKWojciech Kowalczyk
Wojciech Kowalczyk
ADAydin Demircioglu
Aydin Demircioglu
SSSharaf-Eldin Shehada
Sharaf-Eldin Shehada
HWHermann Wendta
Hermann Wendta
Daniel WendtDaniel Wendt
Daniel Wendt
Objectives: We aimed to compare the in vitro flow dynamics of the Perimount Magna Ease™ (PME) and the Trifecta™ (TF) bioprostheses. Material and methods: A new flow chamber was designed to compare the flow patterns of the PME (Edwards Lifesciences, Irvine, CA, USA) and the TF (SJM, St. Paul, MN, USA) aortic valve prostheses. This new channel offered the possibility of 2D-particle-image-velocimetry (2D-PIV) to completely evaluate the flow field downstream from the aortic valve to the middle of the aortic arch. Maximum average velocities, vorticity, shear strength, maximum orifice diameters and jet flow diameters were analyzed. Valve sizes of 21, 23 and 25 mm were evaluated. Results: Average velocity values, shear strength and vorticities were smaller in the flow field of the TF (maximum average velocity: 0.81 ± 0.03m/s, PME 23 mm vs. 0.7 ± 0.02m/s TF 23 mm, P < .001) under pulsatile flow conditions (70 Hz, 70 mL stroke volume). The evaluation of the upper orifice area revealed bigger maximum diameters during the peak flow phase for the TF, but more leaflet-flutter. Conclusions: Our flow chamber allowed a precise and highly sensitive characterization and comparison of complex fluid dynamics of different aortic valve prostheses. Both the Trifecta™ and the Perimount Magna Ease™ showed a good performance on a high level.

28 January 2019 in Robotics
Verified
Journal Article
Open access
PDF file
JHJulian Hoth
Julian Hoth
WKWojciech Kowalczyk
Wojciech Kowalczyk
Autonomous underwater vehicles (AUVs) have changed the way marine environment is surveyed, monitored and mapped. Autonomous underwater vehicles have a wide range of applications in research, military, and commercial settings. AUVs not only perform a given task but also adapt to changes in the environment, e.g., sudden side currents, downdrafts, and other effects which are extremely unpredictable. To navigate properly and allow simultaneous localisation and mapping (SLAM) algorithms to be used, these effects need to be detected. With current navigation systems, these disturbances in the water flow are not measured directly. Only the indirect effects are observed. It is proposed to detect the disturbances directly by placing pressure sensors on the surface of the AUV and processing the pressure data obtained. Within this study, the applicability of different learning methods for determining flow parameters of a surrounding fluid from pressure on an AUV body are tested. This is based on CFD simulations using pressure data from specified points on the surface of the AUV. It is shown that support vector machines are most suitable for the given task and yield excellent results.

1 January 2011
Verified
Journal Article
Closed access
SSSebastian Stühle
Sebastian Stühle
Daniel WendtDaniel Wendt
Daniel Wendt
GHGuojun Houl
Guojun Houl
HWHermann Wendt
Hermann Wendt
MSMarc Schlamann
Marc Schlamann
WKWojciech Kowalczyk
Wojciech Kowalczyk