Yana Fedorovna Ivanova

Mrs. Yana Fedorovna Ivanova


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 September 2022 in Fluids
Verified
Journal Article
Open access
PDF file
YIYana Fedorovna Ivanova
Yana Fedorovna Ivanova
AYAndrey Yukhnev
Andrey Yukhnev
LTLudmila Tikhomolova
Ludmila Tikhomolova
ESEvgueni Smirnov
Evgueni Smirnov
AVAndrey Vrabiy
Andrey Vrabiy
VVValery Vavilov
Valery Vavilov
Femoral artery bypass surgery needs postoperative monitoring due to the high complication risks after bypass. Numerical simulation is an effective tool to help solve this task. This work presents the experience of patient-specific CFD simulation of blood flow in proximal anastomosis for femoral-popliteal bypass, including patient follow-up after bypass surgery. Six cases of proximal anastomosis of femoral-popliteal bypass 3–30 months after surgery were studied. A repeated study was performed for four patients to monitor geometric and hemodynamic changes. The blood flow structure variety in proximal anastomoses and the blood flow dynamics during the cardiac cycle are described in detail using CFD simulation. Special attention is paid to time-average wall shear stresses (TAWSS) and oscillatory shear index (OSI) distributions. Low and oscillatory wall shear stresses were registered in the graft downstream from the suture, especially in case of low inlet flow. It was shown that the postoperative geometry changes led to significant hemodynamic changes; thereby, neointima has grown in areas with initially low and oscillatory wall shear stresses.

1 November 2019 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
PDF file
YIYana Fedorovna Ivanova
Yana Fedorovna Ivanova
AYA D Yukhnev
A D Yukhnev
YGY A Gataulin
Y A Gataulin
ESE M Smirnov
E M Smirnov
DTD A Tarkhov
D A Tarkhov
ABA E Berkovich
A E Berkovich
The present work is aimed at development of a method for estimation of the accuracy of ultrasound thermometry (UST) when applying during local HIFU heating of a tissue-mimicking material (TMM). The method is based on comparison of the ultrasound measurement results with a temperature field reconstructed inside the TMM using data of the infrared (IR) camera surface measurements. In the case presented, the HIFU transducer heated up the TMM by 30 °C for 10 s in the focus area. Ultrasound signals were processed using an in-house UST application software. A 3D temperature field inside the TMM was reconstructed using a method based on the neural network approach. As a result, it has been achieved a good agreement between the UST measurement data and the reconstructed temperature field, especially for the points along the HIFU transducer axis.

1 December 2020 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
PDF file
YIYana Fedorovna Ivanova
Yana Fedorovna Ivanova
AYA D Yukhnev
A D Yukhnev
YGY A Gataulin
Y A Gataulin
ESE M Smirnov
E M Smirnov
DTD A Tarkhov
D A Tarkhov
ABA E Berkovich
A E Berkovich
High Intensity Focused Ultrasound (HIFU) is widely used in modern medicine. One of the important applications is the ablation of internal organ tumors under the HIFU heating. During this procedure, it is necessary to monitor the temperature in healthy adjacent tissues. Ultrasound thermometry (UST) is a promising non-invasive method of temperature control. The paper presents implementation of the UST technique in case of short-term local heating. A new algorithm suggested for ultrasound data processing improves the accuracy of the ultrasound thermometry technique to 2 °C.