Andrey Yukhnev

Dr. Andrey Yukhnev


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2023 in Fluid Dynamics
Verified
Journal Article
Open access
PDF file
VMV. M. Molochnikov
V. M. Molochnikov
NDN. S. Dushin
N. S. Dushin
NPN. D. Pashkova
N. D. Pashkova
YGYakov Gataulin
Yakov Gataulin
ESE. M. Smirnov
E. M. Smirnov
AYAndrey Yukhnev
Andrey Yukhnev
The results of experimental studies and numerical simulation of the flow structure in the separation region downstream of an asymmetric narrowing of smooth canal that simulates 70% one-sided stenosis of the artery are presented. The Reynolds number was equal to 1800. The instantaneous flow velocity vector fields were measured using the SIV technique. The numerical solution was obtained by the large eddy simulation (LES) method. Setting the disturbances in numerical simulation close to the experimental conditions made it possible to obtain a satisfactory agreement between the calculated and experimental velocity fields and the components of the Reynolds stress tensor. The data on formation of the local flow turbulence region behind the constriction and subsequent downstream flow relaminarization are obtained. It is shown that a pair of secondary eddies localized within the region of flow separation is formed near the throat of the constriction.

21 September 2022 in Fluids
Verified
Journal Article
Open access
PDF file
YIYana Fedorovna Ivanova
Yana Fedorovna Ivanova
AYAndrey Yukhnev
Andrey Yukhnev
LTLudmila Tikhomolova
Ludmila Tikhomolova
ESEvgueni Smirnov
Evgueni Smirnov
AVAndrey Vrabiy
Andrey Vrabiy
VVValery Vavilov
Valery Vavilov
Femoral artery bypass surgery needs postoperative monitoring due to the high complication risks after bypass. Numerical simulation is an effective tool to help solve this task. This work presents the experience of patient-specific CFD simulation of blood flow in proximal anastomosis for femoral-popliteal bypass, including patient follow-up after bypass surgery. Six cases of proximal anastomosis of femoral-popliteal bypass 3–30 months after surgery were studied. A repeated study was performed for four patients to monitor geometric and hemodynamic changes. The blood flow structure variety in proximal anastomoses and the blood flow dynamics during the cardiac cycle are described in detail using CFD simulation. Special attention is paid to time-average wall shear stresses (TAWSS) and oscillatory shear index (OSI) distributions. Low and oscillatory wall shear stresses were registered in the graft downstream from the suture, especially in case of low inlet flow. It was shown that the postoperative geometry changes led to significant hemodynamic changes; thereby, neointima has grown in areas with initially low and oscillatory wall shear stresses.

1 December 2015 in St. Petersburg Polytechnical University Journal: Physics and Mathematics
Verified
Journal Article
Open access
YGYakov Gataulin
Yakov Gataulin
DZDmitriy K. Zaitsev
Dmitriy K. Zaitsev
ESEvgueni M. Smirnov
Evgueni M. Smirnov
EFEkaterina A. Fedorova
Ekaterina A. Fedorova
AYAndrey Yukhnev
Andrey Yukhnev
Investigation of weakly swirling flow in a model of a blood vessel with asymmetrical stenosis has been performed using both experimental flow measurement techniques (ultrasound Doppler) and computational fluid dynamics methods. A special attention is paid to getting data for the length of the reverse-flow zone occurring past the stenosis. It has been established that the laminar steady-state flow model is acceptable for numerical analysis of flow past the given-geometry stenosis at Reynolds number values less than 300. At higher values of this parameter, application of the semi-empirical k-ω SST turbulence model is preferable. It has been shown that flow swirl can lead to an increase of the reverse-flow zone

26 June 2019
Verified
Book Chapter
Closed access
PDF file
AYAndrey Yukhnev
Andrey Yukhnev
DTDmitriy Tarkhov
Dmitriy Tarkhov
YGYakov Gataulin
Yakov Gataulin
YIYana Ivanova
Yana Ivanova
ABAlexander Berkovich
Alexander Berkovich

4 March 2024 in Fluids
Verified
Journal Article
Open access
PDF file
AYAndrey Yukhnev
Andrey Yukhnev
LTLudmila Tikhomolova
Ludmila Tikhomolova
YGYakov Gataulin
Yakov Gataulin
AMAlexandra Marinova
Alexandra Marinova
ESEvgueni Smirnov
Evgueni Smirnov
GKGennady Khubulava
Gennady Khubulava
This paper presents the experience of using the V Flow high-frame-rate ultrasound vector imaging method to study the pulsatile velocity fields in the area of the proximal anastomosis for femoral popliteal bypass surgery in vitro and in vivo. A representative (average) anastomosis model and the experimental setup designed for in vitro studies covering forward and reverse flow phases throughout the cycle are described. The results of the measurements are presented for areas with a relatively uniform velocity distribution and for areas with pronounced spatial inhomogeneities due to the jet or recirculating nature of the flow. The results of ultrasonic studies of the velocity field of the three-dimensional pulsatile flow in vitro and in vivo are compared with the data of numerical simulations carried out for the average and personalized models based on the Navier–Stokes equations. Acceptable consistency between the results of experimental and numerical studies is demonstrated.

18 June 2018 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
PDF file
ABAleksander E. Berkovich
Aleksander E. Berkovich
ESEvgueni M. Smirnov
Evgueni M. Smirnov
AYAndrey Yukhnev
Andrey Yukhnev
YGYakov A. Gataulin
Yakov A. Gataulin
DSDaria E. Sinitsyna
Daria E. Sinitsyna
DTDmitriy A. Tarkhov
Dmitriy A. Tarkhov
A phantom with heating of tissue-equivalent material has been designed to elaborate the method of ultrasound thermometry. Algorithms have been developed to evaluate backscatter ultrasound signals shift caused by temperature-sensitivity of the speed of sound. Time-dependent material temperature field needed for estimation of the method accuracy was measured with thermistor probes.