To verify the performance of the high-resolution fully polarimetric synthetic aperture radar (SAR) sensor carried by the Xinzhou 60 remote-sensing aircraft, we used corner reflectors to calibrate the acquired data. The target mechanism in high-resolution SAR images is more complex than it is in low-resolution SAR images, the impact of the point target pointing error on the calibration results is more obvious, and the target echo signal of high-resolution images is more easily affected by speckle noise; thus, more accurate extraction of the point target position and the response energy is required. To solve this problem, this paper introduces image context information and proposes a method to precisely determine the integration region of the corner reflector using sliding windows based on the integral method. The validation indicates that the fully polarimetric SAR sensor on the Xinzhou 60 remote-sensing aircraft can accurately reflect the radiometric characteristics of the ground features and that the integral method can obtain more stable results than the peak method. The sliding window allows the position of the point target to be determined more accurately, and the response energy extracted from the image via the integral method is closer to the theoretical value, which means that the high-resolution SAR system can achieve a higher radiometric calibration accuracy. Additionally, cross-validation reveals that the airborne SAR images have similar quality levels to Sentinel-1A and Gaofen-3 images.
C-SAR/01, the successor of China’s Gaofen-3 Satellite, which launched on 23 November 2021, is the first synthetic aperture radar (SAR) satellite to be launched in China’s civil space infrastructure plan and has served as an invaluable data resource. Radiometric calibration and validation are prerequisites for the quantitative application of SAR data. In this study, the radiometric calibration experiments of C-SAR/01 data of the ultra-fine strip (UFS) and fine strip I (FSI) modes were conducted applying flexible automatic triangular trihedral corner reflectors deployed in Xilinhot SAR satellite calibration and validation site. Accordingly, the image quality and radiometric calibration accuracy were evaluated. The results show that the spatial resolution, peak sidelobe ratio, and integrated sidelobe ratio of UFS and FSI mode data of C-SAR/01 are better than those of the design indexes, and the calibration results from the integral method are more stable than those from the peak method. Furthermore, the standard deviation of the calibration constant for UFS mode data is 0.234 dB, with the relative and absolute calibration accuracies obtained as 0.233 and 0.532 dB, respectively, whereas the standard deviation calibration constant for FSI mode data is 0.198 dB, with its relative and absolute calibration accuracies evaluated as 0.199 and 0.333 dB, respectively.
Validation is the basis of synthetic aperture radar (SAR) image quantification applications. Based on the point target of the field site, the radiation characteristics of the backscattering coefficient image can be used to optimize the SAR imaging, and the product production system can be more closely targeted, to ensure the image product accuracy in the actual quantification application. In this study, the validation of the backscattering coefficient image was examined using calibrators, and the radiometric properties of the image were evaluated by extracting the radar cross-section of each point target. Bilinear interpolation and fast Fourier transform (FFT) interpolation methods were introduced for the local area interpolation of point targets, and the two methods were compared from the perspective of response function imaging and validation accuracy. The results show that the FFT interpolation method is more favorable for validating the backscattering coefficient.
C-SAR/01 and C-SAR/02 serve as successors to the GF-3 satellite. They are designed to operate in tandem with GF-3, collectively forming a C-band synthetic aperture radar (SAR) satellite constellation. This constellation aims to achieve 1 m resolution imaging with a revisit rate of one day. It can effectively cater to various applications such as marine disaster prevention, monitoring marine dynamic environments, and supporting marine scientific research, disaster mitigation, environmental protection, and agriculture. Geometric correction plays a pivotal role in acquiring highly precise geographic location data for ground targets. The geometric positioning accuracy without control points signifies the SAR satellite’s geometric performance. However, SAR images do not exhibit a straightforward image-point–object-point correspondence, unlike optical images. In this study, we introduce a novel approach employing high-precision automatic trihedral corner reflectors as ground control points (GCPs) to assess the geometric positioning accuracy of SAR images. A series of satellite-ground synchronization experiments was conducted at the Xilinhot SAR satellite calibration and validation site to evaluate the geometric positioning accuracy of different C-SAR image modes. Firstly, we calculated the azimuth and elevation angles of the corner reflectors based on satellite orbit parameters. During satellite transit, these corner reflectors were automatically adjusted to align with the radar-looking direction. We subsequently measured the exact longitude and latitude coordinates of the corner reflector vertex in situ using a high-precision real-time kinematics instrument. Next, we computed the theoretical image coordinates of the corner reflectors using the rational polynomial coefficients (RPC) model. After that, we determined the accurate position of the corner reflector in the Single Look Complex (SLC) SAR image using FFT interpolation and the sliding window method. Finally, we evaluated and validated the geometric positioning accuracy of C-SAR images by comparing the two coordinates. The preliminary results indicate that the positioning accuracy varies based on the satellite, imaging modes, and orbital directions. Nevertheless, for most sample points, the range positioning accuracy was better than 60 m, and the azimuth positioning accuracy was better than 80 m. These findings can serve as a valuable reference for subsequent applications of C-SAR satellites.