Lu Li

Ms. Lu Li


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 December 2022 in Remote Sensing
Verified
Journal Article
Open access
PDF file
HQHuang Qiqi
Huang Qiqi
FZFengli Zhang
Fengli Zhang
LLLu Li
Lu Li
XLXiaochen Liu
Xiaochen Liu
YJYanan Jiao
Yanan Jiao
Huirong LiHuirong Li
Huirong Li
C-SAR/01, the successor of China’s Gaofen-3 Satellite, which launched on 23 November 2021, is the first synthetic aperture radar (SAR) satellite to be launched in China’s civil space infrastructure plan and has served as an invaluable data resource. Radiometric calibration and validation are prerequisites for the quantitative application of SAR data. In this study, the radiometric calibration experiments of C-SAR/01 data of the ultra-fine strip (UFS) and fine strip I (FSI) modes were conducted applying flexible automatic triangular trihedral corner reflectors deployed in Xilinhot SAR satellite calibration and validation site. Accordingly, the image quality and radiometric calibration accuracy were evaluated. The results show that the spatial resolution, peak sidelobe ratio, and integrated sidelobe ratio of UFS and FSI mode data of C-SAR/01 are better than those of the design indexes, and the calibration results from the integral method are more stable than those from the peak method. Furthermore, the standard deviation of the calibration constant for UFS mode data is 0.234 dB, with the relative and absolute calibration accuracies obtained as 0.233 and 0.532 dB, respectively, whereas the standard deviation calibration constant for FSI mode data is 0.198 dB, with its relative and absolute calibration accuracies evaluated as 0.199 and 0.333 dB, respectively.

1 January 2022 in Sensors
Verified
Journal Article
Open access
PDF file
LLLu Li
Lu Li
FZFengli Zhang
Fengli Zhang
YSYun Shao
Yun Shao
QWQiufang Wei
Qiufang Wei
HQHuang Qiqi
Huang Qiqi
YJYanan Jiao
Yanan Jiao
To verify the performance of the high-resolution fully polarimetric synthetic aperture radar (SAR) sensor carried by the Xinzhou 60 remote-sensing aircraft, we used corner reflectors to calibrate the acquired data. The target mechanism in high-resolution SAR images is more complex than it is in low-resolution SAR images, the impact of the point target pointing error on the calibration results is more obvious, and the target echo signal of high-resolution images is more easily affected by speckle noise; thus, more accurate extraction of the point target position and the response energy is required. To solve this problem, this paper introduces image context information and proposes a method to precisely determine the integration region of the corner reflector using sliding windows based on the integral method. The validation indicates that the fully polarimetric SAR sensor on the Xinzhou 60 remote-sensing aircraft can accurately reflect the radiometric characteristics of the ground features and that the integral method can obtain more stable results than the peak method. The sliding window allows the position of the point target to be determined more accurately, and the response energy extracted from the image via the integral method is closer to the theoretical value, which means that the high-resolution SAR system can achieve a higher radiometric calibration accuracy. Additionally, cross-validation reveals that the airborne SAR images have similar quality levels to Sentinel-1A and Gaofen-3 images.

16 July 2024 in Sensors
Verified
Journal Article
Open access
PDF file
YFYE FEI
YE FEI
XWXiaopeng Wang
Xiaopeng Wang
LLLu Li
Lu Li
YCYubao Chen
Yubao Chen
YLYongheng Lei
Yongheng Lei
ZHZehao Huang
Zehao Huang
Weather radar is an active remote sensing device used to monitor the full lifecycle changes in severe convective weather with high spatial and temporal resolution. Effective radar calibration is a crucial foundation for ensuring the high-quality application of observational data. This paper utilizes a UAV platform equipped with a high-precision RTK system and standard metal spheres to study the principles and methods of metal sphere calibration, constructing a complete calibration process and calibration accuracy evaluation metrics. Additionally, a collocated radar comparison observation experiment was conducted for cross-validation, and metal sphere calibration tests were performed on problematic radars. The experimental results indicate the following: (1) The combined application of a high-precision RTK system and a laser range camera can provide real-time position information on the metal sphere, improving the efficiency of radar target acquisition. (2) The calibration method based on UAV-suspended metal spheres can periodically conduct the quantitative calibration of Z and ZDR, achieving calibration accuracies within 0.5 dB and 0.2 dB, respectively, and supports the qualitative inspection of key parameters such as beamwidth and pulse width. (3) During field tests, a high success rate “coarse adjustment + fine adjustment + staring” sphere-finding technique was established, based on automatic switching between RHI, PPI, and FIX scanning modes. This method directs the UAV to adjust the metal sphere to the center of the radar distance bin, reducing the impact of uneven beam filling and bin crossing, ensuring the accuracy of scattering characteristic measurements.

1 January 2023 in Sensors
Verified
Journal Article
Open access
PDF file
YJYanan Jiao
Yanan Jiao
FZFengli Zhang
Fengli Zhang
HQHuang Qiqi
Huang Qiqi
XLXiaochen Liu
Xiaochen Liu
LLLu Li
Lu Li
Validation is the basis of synthetic aperture radar (SAR) image quantification applications. Based on the point target of the field site, the radiation characteristics of the backscattering coefficient image can be used to optimize the SAR imaging, and the product production system can be more closely targeted, to ensure the image product accuracy in the actual quantification application. In this study, the validation of the backscattering coefficient image was examined using calibrators, and the radiometric properties of the image were evaluated by extracting the radar cross-section of each point target. Bilinear interpolation and fast Fourier transform (FFT) interpolation methods were introduced for the local area interpolation of point targets, and the two methods were compared from the perspective of response function imaging and validation accuracy. The results show that the FFT interpolation method is more favorable for validating the backscattering coefficient.