Alvaro Jesus Gutierrez Bautista

Dr. Alvaro Jesus Gutierrez Bautista

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2019 in Journal of Applied Physiology
Verified
Journal Article
Closed access
IAIsaac Almendros
Isaac Almendros
PMPaula Martínez-Ros
Paula Martínez-Ros
NFNuria Farre
Nuria Farre
MRMónica Rubio-Zaragoza
Mónica Rubio-Zaragoza
MTMarta Torres
Marta Torres
RFRamon Farre
Ramon Farre
Obstructive sleep apnea (OSA), characterized by events of hypoxia-reoxygenation, is highly prevalent in pregnancy, negatively affecting the gestation process and particularly the fetus. Whether the consequences of OSA for the fetus and offspring are mainly caused by systemic alterations in the mother or by a direct effect of intermittent hypoxia in the fetus is unknown. In fact, how apnea-induced hypoxemic swings in OSA are transmitted across the placenta remains to be investigated. The aim of this study was to test the hypothesis, based on a theoretical background on the damping effect of oxygen transfer in the placenta, that oxygen partial pressure (Po2) swings resulting from obstructive apneas mimicking OSA are mitigated in the fetal circulation. To this end, four anesthetized ewes close to term pregnancy were subjected to obstructive apneas consisting of 25-s airway obstructions. Real-time Po2 was measured in the maternal carotid artery and in the umbilical vein with fast-response fiber-optic oxygen sensors. The amplitudes of Po2 swings in the umbilical vein were considerably smaller [3.1 ± 1.0 vs. 21.0 ± 6.1 mmHg (mean ± SE); P < 0.05]. Corresponding estimated swings in fetal and maternal oxyhemoglobin saturation tracked Po2 swings. This study provides novel insights into fetal oxygenation in a model of gestational OSA and highlights the importance of further understanding the impact of sleep-disordered breathing on fetal and offspring development. NEW & NOTEWORTHY This study in an airway obstruction sheep model of gestational sleep apnea provides novel data on how swings in oxygen partial pressure (Po2) translate from maternal to fetal blood. Real-time simultaneous measurement of Po2 in maternal artery and in umbilical vein shows that placenta transfer attenuates the magnitude of oxygenation swings. These data prompt further investigation of the extent to which maternal apneas could induce similar direct oxidative stress in fetal and maternal tissues.

1 January 2021 in Journal of Veterinary Science
Verified
Journal Article
Open access
HLHannah Leigh
Hannah Leigh
MGMiguel Gozalo-Marcilla
Miguel Gozalo-Marcilla
VEVicente Esteve
Vicente Esteve
ABAlvaro Jesus Gutierrez Bautista
Alvaro Jesus Gutierrez Bautista
TGTamara Martin Gimenez
Tamara Martin Gimenez
JVJaime Viscasillas
Jaime Viscasillas
Leigh H, et al. J Vet Sci. 2021 Feb;22:e22. https://doi.org/10.4142/jvs.2021.22.e22

1 November 2018 in Veterinary Anaesthesia and Analgesia
Verified
Journal Article
Closed access
ABAlvaro Jesus Gutierrez Bautista
Alvaro Jesus Gutierrez Bautista
JMJuan Morgaz
Juan Morgaz
MGMaría del Mar Granados
María del Mar Granados
RGRafael J. Gómez-Villamandos
Rafael J. Gómez-Villamandos
JDJuan M. Dominguez
Juan M. Dominguez
RNRocío Navarrete-Calvo
Rocío Navarrete-Calvo

21 November 2023 in Animals
Verified
Journal Article
Open access
PDF file
ABAlvaro Jesus Gutierrez Bautista
Alvaro Jesus Gutierrez Bautista
FSFranz Josef Söbbeler
Franz Josef Söbbeler
RKRuediger Koch
Ruediger Koch
JVJaime Viscasillas
Jaime Viscasillas
SKSabine Beate Rita Kästner
Sabine Beate Rita Kästner
In neonatal equines, pathologies involving umbilical structures are an important cause of morbidity, and surgical removal of urachal remnants is a common procedure in clinical practice. Surgery involving the ventral abdominal wall can cause substantial pain, leading to complications and prolonged recovery. The objectives of this study were to describe a two-point bilateral ultrasound-guided rectus sheath block at the level of the umbilicus and to evaluate the extent of dye distribution in foal cadavers. Ten foal cadavers were included in the study, in which a bilateral two-point ultrasound-guided rectus sheath block was performed—one injection 5 cm cranially and a second one 5 cm caudally to the umbilicus. The injectate consisted of a mixture of iodinated contrast medium and blue dye at a volume of 0.25 mL kg−1 per injection point (total 1 mL kg−1). After the injection, computer tomography and subsequent dissection of the ventral abdominal wall were performed. The extension of the contrast medium, the number of stained nerves, and contamination of the abdominal cavity were evaluated. The cranio-caudal extension of the contrast ranged from 0.8 to 1.4 cm per milliliter of injectate. The most commonly stained ventral branches of spinal nerves were thoracic (Th) nerves 16, 17, and 18 (95%, 85%, and 80% of the nerves, respectively). Abdominal contamination was found in four animals. The results suggest that the block could provide periumbilical analgesia. Further studies with different volumes of injectate and living animals are warranted.

27 January 2021 in Regional Anesthesia & Pain Medicine
Verified
Journal Article
Closed access
PDF file
CGCarles García-Vitoria
Carles García-Vitoria
MGMireia García-Roselló
Mireia García-Roselló
MRMiguel A. Reina
Miguel A. Reina
JAJose De Andres
Jose De Andres
ABAlvaro Jesus Gutierrez Bautista
Alvaro Jesus Gutierrez Bautista
JRJosé Ignacio Redondo
José Ignacio Redondo
Background We designed a device to close accidental dural puncture via the offending puncturing epidural needle directly after diagnosis of the puncture and before removing the needle. The aim of this study was to quantify this device’s ability to seal cerebrospinal fluid leakage. Methods Forty-six anesthetized adult sheep were studied in a single-blind randomized controlled fashion in two equal groups. An intentional dural puncture was performed with an 18-gage Tuohy needle on all the sheep between L6 and S1 levels. Contrast medium was injected through the needle. Twenty-three animals receive treatment with the sealing device. Two minutes after device placement, or dural puncture in the control group, a CT scan was performed on the animals to estimate contrast material leakage. A region of interest (ROI) was defined as the region that enclosed the subarachnoid space, epidural space, and neuroforaminal canal (the vertebral body above and half of its equivalent height in sacrum below the puncture site). In this region, the total contrast volume and the volumes in the epidural space (EPIDURAL) were measured. The primary outcome measure was the EPIDURAL/ROI ratio to ascertain the proportion of intrathecally injected fluid that passed into the epidural space in both groups. The secondary outcomes were the total amount of contrast in the ROI and the EPIDURAL. Results The device was deployed successfully in all but two instances, where it suffered from manufacturing defects. Leakage was less in the study group (1.0 vs 1.4 mL, p=0.008). The median EPIDURAL/ROI ratio was likewise less in the study group (29 vs 46; p=0.013; 95% CI (−27 to –3.5)). Conclusion This novel dural puncture-sealing device, also envisaged to be used in other comparable iatrogenic leakage scenarios to be identified in the future, was able to reduce the volume of cerebrospinal fluid that leaked into the epidural space after dural puncture. The device is possibly a valuable way of preventing fluid leakage immediately after the recognition of membrane puncture.

31 May 2024 in Animals
Verified
Journal Article
Open access
PDF file
ABAlvaro Jesus Gutierrez Bautista
Alvaro Jesus Gutierrez Bautista
MMManon Mikic
Manon Mikic
POPablo E Otero
Pablo E Otero
VRVirginia Rega
Virginia Rega
FMFrancisco Medina-Bautista
Francisco Medina-Bautista
AWAdriano Wang-Leandro
Adriano Wang-Leandro
The trigeminal nerve is responsible for innervating the periorbita. Ultrasound-guided trigeminal block is employed in humans for trigeminal neuralgia or periorbital surgery. There are no studies evaluating this block in dogs. This study aims to evaluate and compare two approaches (coronoid and temporal) of the trigeminal nerve block. We hypothesised superior staining with the coronoid approach. Thirteen dog heads were used. After a preliminary anatomical study, two ultrasound-guided injections per head (right and left, coronoid and temporal approach, randomly assigned), with an injectate volume of 0.15 mL cm−1 of cranial length, were performed (iodinated contrast and tissue dye mixture). The ultrasound probe was placed over the temporal region, visualising the pterygopalatine fossa. For the temporal approach, the needle was advanced from the medial aspect of the temporal region in a dorsoventral direction. For the coronoid approach, it was advanced ventral to the zygomatic arch in a lateromedial direction. CT scans and dissections were conducted to assess and compare the position of the needle, the spread of the injectate, and nerve staining. No significant differences were found. Both approaches demonstrated the effective interfascial distribution of the injectate, with some minimal intracranial spread. Although the coronoid approach did not yield superior staining as hypothesised, it presents a viable alternative to the temporal approach. Studies in live animals are warranted to evaluate clinical efficacy and safety.