Stefan Schröder

Dr. Stefan Schröder

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 February 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
SSStefan Schröder
Stefan Schröder
Thomas StrunskusThomas Strunskus
Thomas Strunskus
SRStefan Rehders
Stefan Rehders
KGKaren K. Gleason
Karen K. Gleason
Franz FaupelFranz Faupel
Franz Faupel
Bulk polytetrafluoroethylene (PTFE) possesses excellent chemical stability and dielectric properties. Indeed, thin films with these same characteristics would be ideal for electret applications. Previously, the electret properties of PTFE-like thin films produced by rf sputtering or plasma enhanced chemical vapor deposition were found to deteriorate due to structural changes and surface oxidation. In this article, the technique of initiated chemical vapor deposition (iCVD) is evaluated for electret applications for the first time. The iCVD method is known for its solvent-free deposition of conformal, pinhole-free polymer thin films in mild process conditions. It is shown that PTFE thin films prepared in this way, show excellent agreement to commercial bulk PTFE with regard to chemical properties and dielectric dissipation factors. After ion irradiation in a corona discharge the iCVD PTFE thin films exhibit stable electret properties, which can be tailored by the process parameters. Due to the mild deposition conditions, the iCVD technique is suitable for deposition on flexible organic substrates for the next-generation electret devices. It is also compatible with state-of-the-art microelectronic processing lines due to the characteristics of conformal growth and easy scaling up to larger size substrates.

1 July 2020 in Materials Today
Verified
Journal Article
Closed access
SSStefan Schröder
Stefan Schröder
OPOleksandr Polonskyi
Oleksandr Polonskyi
TSThomas Strunskus
Thomas Strunskus
FFFranz Faupel
Franz Faupel

19 January 2023 in Polymers
Verified
Journal Article
Open access
PDF file
SSStefan Schröder
Stefan Schröder
Ababii NicolaiAbabii Nicolai
Ababii Nicolai
Mihai BrînzăMihai Brînză
Mihai Brînză
NMNicolae Magariu
Nicolae Magariu
LZLukas Zimoch
Lukas Zimoch
Oleg LupanOleg Lupan
Oleg Lupan
Metal oxide gas sensors are of great interest for applications ranging from lambda sensors to early hazard detection in explosive media and leakage detection due to their superior properties with regard to sensitivity and lifetime, as well as their low cost and portability. However, the influence of ambient gases on the gas response, energy consumption and selectivity still needs to be improved and they are thus the subject of intensive research. In this work, a simple approach is presented to modify and increase the selectivity of gas sensing structures with an ultrathin polymer thin film. The different gas sensing surfaces, CuO, Al2O3/CuO and TiO2 are coated with a conformal < 30 nm Poly(1,3,5,7-tetramethyl-tetravinyl cyclotetrasiloxane) (PV4D4) thin film via solvent-free initiated chemical vapor deposition (iCVD). The obtained structures demonstrate a change in selectivity from ethanol vapor to 2-propanol vapor and an increase in selectivity compared to other vapors of volatile organic compounds. In the case of TiO2 structures coated with a PV4D4 thin film, the increase in selectivity to 2-propanol vapors is observed even at relatively low operating temperatures, starting from >200 °C. The present study demonstrates possibilities for improving the properties of metal oxide gas sensors, which is very important in applications in fields such as medicine, security and food safety.

1 June 2018 in Organic Electronics
Verified
Journal Article
Closed access
RHRalph E. Hirschberg
Ralph E. Hirschberg
MSMichael Scharnberg
Michael Scharnberg
SSStefan Schröder
Stefan Schröder
SRStefan Rehders
Stefan Rehders
TSThomas Strunskus
Thomas Strunskus
Franz FaupelFranz Faupel
Franz Faupel

11 May 2023 in Biosensors
Verified
Journal Article
Open access
PDF file
Mihai BrînzăMihai Brînză
Mihai Brînză
SSStefan Schröder
Stefan Schröder
Ababii NicolaiAbabii Nicolai
Ababii Nicolai
MGMonja Gronenberg
Monja Gronenberg
Thomas StrunskusThomas Strunskus
Thomas Strunskus
Oleg LupanOleg Lupan
Oleg Lupan
Certain molecules act as biomarkers in exhaled breath or outgassing vapors of biological systems. Specifically, ammonia (NH3) can serve as a tracer for food spoilage as well as a breath marker for several diseases. H2 gas in the exhaled breath can be associated with gastric disorders. This initiates an increasing demand for small and reliable devices with high sensitivity capable of detecting such molecules. Metal-oxide gas sensors present an excellent tradeoff, e.g., compared to expensive and large gas chromatographs for this purpose. However, selective identification of NH3 at the parts-per-million (ppm) level as well as detection of multiple gases in gas mixtures with one sensor remain a challenge. In this work, a new two-in-one sensor for NH3 and H2 detection is presented, which provides stable, precise, and very selective properties for the tracking of these vapors at low concentrations. The fabricated 15 nm TiO2 gas sensors, which were annealed at 610 °C, formed two crystal phases, namely anatase and rutile, and afterwards were covered with a thin 25 nm PV4D4 polymer nanolayer via initiated chemical vapor deposition (iCVD) and showed precise NH3 response at room temperature and exclusive H2 detection at elevated operating temperatures. This enables new possibilities in application fields such as biomedical diagnosis, biosensors, and the development of non-invasive technology.

7 February 2020 in Macromolecules
Verified
Journal Article
Closed access
MBMaximilian H. Burk
Maximilian H. Burk
SSStefan Schröder
Stefan Schröder
WMWidukind Moormann
Widukind Moormann
DLDaniel Langbehn
Daniel Langbehn
Thomas StrunskusThomas Strunskus
Thomas Strunskus
Franz FaupelFranz Faupel
Franz Faupel