Nicolae Magariu

Dr. Nicolae Magariu

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 January 2023 in Polymers
Verified
Journal Article
Open access
PDF file
SSStefan Schröder
Stefan Schröder
Ababii NicolaiAbabii Nicolai
Ababii Nicolai
Mihai BrînzăMihai Brînză
Mihai Brînză
NMNicolae Magariu
Nicolae Magariu
LZLukas Zimoch
Lukas Zimoch
Oleg LupanOleg Lupan
Oleg Lupan
Metal oxide gas sensors are of great interest for applications ranging from lambda sensors to early hazard detection in explosive media and leakage detection due to their superior properties with regard to sensitivity and lifetime, as well as their low cost and portability. However, the influence of ambient gases on the gas response, energy consumption and selectivity still needs to be improved and they are thus the subject of intensive research. In this work, a simple approach is presented to modify and increase the selectivity of gas sensing structures with an ultrathin polymer thin film. The different gas sensing surfaces, CuO, Al2O3/CuO and TiO2 are coated with a conformal < 30 nm Poly(1,3,5,7-tetramethyl-tetravinyl cyclotetrasiloxane) (PV4D4) thin film via solvent-free initiated chemical vapor deposition (iCVD). The obtained structures demonstrate a change in selectivity from ethanol vapor to 2-propanol vapor and an increase in selectivity compared to other vapors of volatile organic compounds. In the case of TiO2 structures coated with a PV4D4 thin film, the increase in selectivity to 2-propanol vapors is observed even at relatively low operating temperatures, starting from >200 °C. The present study demonstrates possibilities for improving the properties of metal oxide gas sensors, which is very important in applications in fields such as medicine, security and food safety.

1 March 2022 in Materials Today Chemistry
Verified
Journal Article
Closed access
SSStefan Schröder
Stefan Schröder
Ababii NicolaiAbabii Nicolai
Ababii Nicolai
OLO. Lupan
O. Lupan
JDJ. Drewes
J. Drewes
NMNicolae Magariu
Nicolae Magariu
Franz FaupelFranz Faupel
Franz Faupel

6 September 2021 in Chemosensors
Verified
Journal Article
Open access
PDF file
Oleg LupanOleg Lupan
Oleg Lupan
HKHelge Krüger
Helge Krüger
LSLeonard Siebert
Leonard Siebert
Ababii NicolaiAbabii Nicolai
Ababii Nicolai
NKNiklas Kohlmann
Niklas Kohlmann
SHSandra Hansen
Sandra Hansen
Lithium-ion batteries (LIBs) still need continuous safety monitoring based on their intrinsic properties, as well as due to the increase in their sizes and device requirements. The main causes of fires and explosions in LIBs are heat leakage and the presence of highly inflammable components. Therefore, it is necessary to improve the safety of the batteries by preventing the generation of these gases and/or their early detection with sensors. The improvement of such safety sensors requires new approaches in their manufacturing. There is a growing role for research of nanostructured sensor’s durability in the field of ionizing radiation that also can induce structural changes in the LIB’s component materials, thus contributing to the elucidation of fundamental physicochemical processes; catalytic reactions or inhibitions of the chemical reactions on which the work of the sensors is based. A current method widely used in various fields, Direct Ink Writing (DIW), has been used to manufacture heterostructures of Al2O3/CuO and CuO:Fe2O3, followed by an additional ALD and thermal annealing step. The detection properties of these 3D-DIW printed heterostructures showed responses to 1,3-dioxolan (DOL), 1,2-dimethoxyethane (DME) vapors, as well as to typically used LIB electrolytes containing LiTFSI and LiNO3 salts in a mixture of DOL:DME, as well also to LiPF6 salts in a mixture of ethylene carbonate (EC) and dimethyl carbonate (DMC) at operating temperatures of 200 °C–350 °C with relatively high responses. The combination of the possibility to detect electrolyte vapors used in LIBs and size control by the 3D-DIW printing method makes these heterostructures extremely attractive in controlling the safety of batteries.

5 May 2024 in Chemosensors
Verified
Journal Article
Open access
PDF file
Oleg LupanOleg Lupan
Oleg Lupan
Mihai BrînzăMihai Brînză
Mihai Brînză
JPJulia Piehl
Julia Piehl
Ababii NicolaiAbabii Nicolai
Ababii Nicolai
NMNicolae Magariu
Nicolae Magariu
SSStefan Schröder
Stefan Schröder
Certain biomarkers in exhaled breath are indicators of diseases in the human body. The non-invasive detection of such biomarkers in human breath increases the demand for simple and cost-effective gas sensors to replace state-of-the-art gas chromatography (GC) machines. The use of metal oxide (MOX) gas sensors based on thin-film structures solves the current limitations of breath detectors. However, the response at high humidity levels, i.e., in the case of exhaled human breath, significantly decreases the sensitivity of MOX sensors, making it difficult to detect small traces of biomarkers. We have introduced, in previous work, the concept of a hybrid gas sensor, in which thin-film-based MOX gas sensors are combined with an ultra-thin (20–30 nm) polymer top layer deposited by solvent-free initiated chemical vapor deposition (iCVD). The hydrophobic top layer enables sensor measurement in high-humidity conditions as well as the precise tuning of selectivity and sensitivity. In this paper, we present a way to increase the hydrogen (H2) sensitivity of hybrid sensors through chemical modification of the polymer top layer. A poly(1,3,5,7-tetramethyl-tetravinylcyclotetrasiloxane) (PV4D4) thin film, already applied in one of our previous studies, is transformed into a silsesquioxane-containing top layer by a simple heating step. The transformation results in a significant increase in the gas response for H2 ~709% at an operating temperature of 350 °C, which we investigate based on the underlying sensing mechanism. These results reveal new pathways in the biomedical application field for the analysis of exhaled breath, where H2 indicates gastrointestinal diseases.

22 October 2025 in Materials Chemistry Frontiers
Verified
Journal Article
Open access
PDF file
Rajat NagpalRajat Nagpal
Rajat Nagpal
MSMasaya Sugihara
Masaya Sugihara
NMNicolae Magariu
Nicolae Magariu
TTTim Tjardts
Tim Tjardts
NLNahomy Meling Lizarde
Nahomy Meling Lizarde
Oleg LupanOleg Lupan
Oleg Lupan
ZIF-8 provides accessible channel to small molecules like hydrogen to pass through the pores to interact at the CuO:Al surface. The interaction strength of VOCs with ZIF-8 is defined by the electronic polarizability of tested VOCs.

12 September 2023
Verified
Book Chapter
Closed access
PDF file
BCBarnika Chakraborty
Barnika Chakraborty
PSPhilipp Schadte
Philipp Schadte
MPMirjam Patricia Margarete Poschmann
Mirjam Patricia Margarete Poschmann
CLCristian Lupan
Cristian Lupan
TZTudor Zadorojneac
Tudor Zadorojneac
RARainer Adelung
Rainer Adelung