François Huber

Dr. François Huber

University of Basel, Basel, Basel-Stadt, Switzerland
orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 February 2013 in Nature Nanotechnology
Verified
Journal Article
Closed access
PDF file
FHFrançois Huber
François Huber
HLHans Peter Lang
Hans Peter Lang
NBN. Backmann
N. Backmann
DRD. Rimoldi
D. Rimoldi
CGCh. Gerber
Ch. Gerber

1 February 2006 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
FHFrançois Huber
François Huber
Martin HegnerMartin Hegner
Martin Hegner
CGChristoph Gerber
Christoph Gerber
HGHans-Joachim Güntherodt
Hans-Joachim Güntherodt
HLHans Peter Lang
Hans Peter Lang

22 November 2010 in Beilstein Journal of Nanotechnology
Verified
Journal Article
Open access
PDF file
NBNatalija Backmann
Natalija Backmann
NKNatascha Kappeler
Natascha Kappeler
TBThomas Braun
Thomas Braun
FHFrançois Huber
François Huber
HLHans Peter Lang
Hans Peter Lang
RLRoderick Lim
Roderick Lim
Polymers are often used to modify surface properties to control interfacial processes. Their sensitivity to solvent conditions and ability to undergo conformational transitions makes polymers attractive in tailoring surface properties with specific functionalities leading to applications in diverse areas ranging from tribology to colloidal stability and medicine. A key example is polyethylene glycol (PEG), which is widely used as a protein-resistant coating given its low toxicity and biocompatibility. We report here a microcantilever-based sensor for the in situ characterization of PEG monolayer formation on Au using the “grafting to” approach. Moreover, we demonstrate how microcantilevers can be used to monitor conformational changes in the grafted PEG layer in different solvent conditions. This is supported by atomic force microscope (AFM) images and force–distance curve measurements of the microcantilever chip surface, which show that the grafted PEG undergoes a reversible collapse when switching between good and poor solvent conditions, respectively.

19 April 2013 in Sensors
Verified
Journal Article
Open access
PDF file
JZJiayun Zhang
Jiayun Zhang
HLHans Peter Lang
Hans Peter Lang
FBFelice Battiston
Felice Battiston
NBNatalija Backmann
Natalija Backmann
FHFrançois Huber
François Huber
CGChristoph Gerber
Christoph Gerber
A cantilever-based protein biosensor has been developed providing a customizable multilayer platform for the detection of antibodies. It consists of a biotin-terminated PEG layer pre-functionalized on the gold-coated cantilever surface, onto which NeutrAvidin is adsorbed through biotin/NeutrAvidin specific binding. NeutrAvidin is used as a bridge layer between the biotin-coated surface and the biotinylated biomolecules, such as biotinylated bovine serum albumin (biotinylated BSA), forming a multilayer sensor for direct antibody capture. The cantilever biosensor has been successfully applied to the detection of mouse anti-BSA (m-IgG) and sheep anti-BSA(s-IgG) antibodies. As expected, the average differential surface stress signals of about 5.7 ± 0.8 ´ 10−3 N/m are very similar for BSA/m-IgG and BSA/s-IgG binding, i.e., they are independent of the origin of the antibody. A statistic evaluation of 112 response curves confirms that the multilayer protein cantilever biosensor shows high reproducibility. As a control test, a biotinylated maltose binding protein was used for detecting specificity of IgG, the result shows a signal of bBSA layer in response to antibody is 5.8 ´ 10−3 N/m compared to bMBP. The pre-functionalized biotin/PEG cantilever surface is found to show a long shelf-life of at least 40 days and retains its responsivity of above 70% of the signal when stored in PBS buffer at 4 °C. The protein cantilever biosensor represents a rapid, label-free, sensitive and reliable detection technique for a real-time protein assay.

9 November 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
FHFrançois Huber
François Huber
HLHans Peter Lang
Hans Peter Lang
SHStefanie Heller
Stefanie Heller
JBJulia Anna Bielicki
Julia Anna Bielicki
CGChristoph Gerber
Christoph Gerber
AEAdrian Egli
Adrian Egli
Sepsis is a life-threatening condition mostly caused by a bacterial infection resulting in inflammatory reaction and organ dysfunction if not treated effectively. Rapid identification of the causing bacterial pathogen already in the early stage of bacteremia is therefore vital. Current technologies still rely on time-consuming procedures including bacterial culturing up to 72 h. Our approach is based on ultra-rapid and highly sensitive nanomechanical sensor arrays. In measurements we observe two clearly distinguishable distributions consisting of samples with bacteria and without bacteria respectively. Compressive surface stress indicates the presence of bacteria. For this proof-of-concept, we extracted total RNA from EDTA whole blood samples from patients with blood-culture-confirmed bacteremia, which is the reference standard in diagnostics. We determined the presence or absence of bacterial RNA in the sample through 16S-rRNA hybridization and species-specific probes using nanomechanical sensor arrays. Via both probes, we identified two clinically highly-relevant bacterial species i.e., Escherichia coli and Staphylococcus aureus down to an equivalent of 20 CFU per milliliter EDTA whole blood. The dynamic range of three orders of magnitude covers most clinical cases. We correctly identified all patient samples regarding the presence or absence of bacteria. We envision our technology as an important contribution to early and sensitive sepsis diagnosis directly from blood without requirement for cultivation. This would be a game changer in diagnostics, as no commercial PCR or POCT device currently exists who can do this.

1 August 2008 in Review of Scientific Instruments
Verified
Journal Article
Closed access
FHFrançois Huber
François Huber
HLHans Peter Lang
Hans Peter Lang
Martin HegnerMartin Hegner
Martin Hegner
MDMichel Despont
Michel Despont
UDUte Drechsler
Ute Drechsler
CGChristoph Gerber
Christoph Gerber
A new microcantilever array design is investigated comprising eight flexible microcantilevers introducing two solid bars, enabling to subtract contributions from differences in refractive index in an optical laser read out system. Changes in the refractive index do not contribute undesirably to bending signals at picomolar to micromolar DNA or protein concentrations. However, measurements of samples with high salt concentrations or serum are affected, requiring corrections for refractive index artifacts. Moreover, to obtain a deeper understanding of molecular stress formation, the differential curvature of cantilevers is analyzed by positioning the laser spots along the surface of the levers during pH experiments.