Christoph Gerber

Dr. Christoph Gerber


Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2006 in Nature Nanotechnology
Verified
Journal Article
Closed access
CGChristoph Gerber
Christoph Gerber
HLHans Peter Lang
Hans Peter Lang

22 November 2010 in Beilstein Journal of Nanotechnology
Verified
Journal Article
Open access
PDF file
NBNatalija Backmann
Natalija Backmann
NKNatascha Kappeler
Natascha Kappeler
TBThomas Braun
Thomas Braun
FHFrançois Huber
François Huber
HLHans Peter Lang
Hans Peter Lang
RLRoderick Lim
Roderick Lim
Polymers are often used to modify surface properties to control interfacial processes. Their sensitivity to solvent conditions and ability to undergo conformational transitions makes polymers attractive in tailoring surface properties with specific functionalities leading to applications in diverse areas ranging from tribology to colloidal stability and medicine. A key example is polyethylene glycol (PEG), which is widely used as a protein-resistant coating given its low toxicity and biocompatibility. We report here a microcantilever-based sensor for the in situ characterization of PEG monolayer formation on Au using the “grafting to” approach. Moreover, we demonstrate how microcantilevers can be used to monitor conformational changes in the grafted PEG layer in different solvent conditions. This is supported by atomic force microscope (AFM) images and force–distance curve measurements of the microcantilever chip surface, which show that the grafted PEG undergoes a reversible collapse when switching between good and poor solvent conditions, respectively.

5 March 2008
Verified
Book Chapter
Closed access
PDF file
HLHans Peter Lang
Hans Peter Lang
CGChristoph Gerber
Christoph Gerber

22 July 2016 in Sensors
Verified
Journal Article
Open access
PDF file
HLHans Peter Lang
Hans Peter Lang
FLFrédéric Loizeau
Frédéric Loizeau
AHAgnès Hiou-Feige
Agnès Hiou-Feige
JRJean-Paul Rivals
Jean-Paul Rivals
PRPedro Romero
Pedro Romero
EMErnst Meyer
Ernst Meyer
For many diseases, where a particular organ is affected, chemical by-products can be found in the patient’s exhaled breath. Breath analysis is often done using gas chromatography and mass spectrometry, but interpretation of results is difficult and time-consuming. We performed characterization of patients’ exhaled breath samples by an electronic nose technique based on an array of nanomechanical membrane sensors. Each membrane is coated with a different thin polymer layer. By pumping the exhaled breath into a measurement chamber, volatile organic compounds present in patients’ breath diffuse into the polymer layers and deform the membranes by changes in surface stress. The bending of the membranes is measured piezoresistively and the signals are converted into voltages. The sensor deflection pattern allows one to characterize the condition of the patient. In a clinical pilot study, we investigated breath samples from head and neck cancer patients and healthy control persons. Evaluation using principal component analysis (PCA) allowed a clear distinction between the two groups. As head and neck cancer can be completely removed by surgery, the breath of cured patients was investigated after surgery again and the results were similar to those of the healthy control group, indicating that surgery was successful.

1 January 2010
Verified
Book Chapter
Closed access
PDF file
HLHans Peter Lang
Hans Peter Lang
Martin HegnerMartin Hegner
Martin Hegner
CGChristoph Gerber
Christoph Gerber

1 January 2017
Verified
Book Chapter
Closed access
PDF file
HLHans Peter Lang
Hans Peter Lang
Martin HegnerMartin Hegner
Martin Hegner
CGChristoph Gerber
Christoph Gerber