(1) Background: Ischemic stroke is one of the leading causes of death and disability. An inflammatory response is observed in multiple stages of cerebral ischemia, particularly in the acute phase. Recent publications revealed that the neutrophil–lymphocyte ratio (NLR) and lymphocyte–monocyte ratio (LMR) may be used to predict long-term prognosis in acute ischemic stroke (AIS) after thrombolysis. To test whether there is a relationship between the combination of these parameters and long-term prognosis, we analyzed the NLR–LMR combination in AIS patients treated with intravenous recombinant tissue plasminogen activator (rtPA); (2) Methods: The study included 285 adults with a diagnosis of AIS and rtPA treatment within a 4.5 h time window. Blood samples were obtained at admission and 24 h after thrombolysis to calculate pre- and post-thrombolysis NLR and LMR. Clinical data, including NIHSS was registered on admission and day 1. The long-term outcome was defined 90 days post-event by the modified Rankin Scale (mRS). Therapy-associated intracranial hemorrhage (ICH) was classified according to ECASS II. Receiver operating characteristic curve (ROC) analysis was performed to determine optimal cutoffs of NLR and LMR as predictors of therapy outcomes; (3) Results: Patients were stratified by cutoffs of 5.73 for NLR and 2.08 for LMR. The multivariate logistic regression model, including all possible confounders, displayed no significant association between NLR or LMR with 3-months functional prognosis. The combination of high NLR–low LMR vs. low NRL–high LMR as obtained 24 h after thrombolysis was found to be an independent predictor of poor 3-months functional outcome (mRS ≥ 2; OR 3.407, 95% CI 1.449 to 8.011, p = 0.005). The proportion of patients between low NLR–high LMR and high NLR–low LMR groups from admission to day 1 showed no significant change in the good outcome group. On the other hand, in the poor outcome group (mRS ≥ 2), low NLR–high LMR and high NLR–low LMR groups displayed a significant shift in patient proportions from 67% and 21% at admission (p = 0.001) to 36% and 49% at 24 h after thrombolysis (p < 0.001), respectively; (4) Conclusions: Our study demonstrated for the first time that a high NLR–low LMR combination as observed at 24 h after thrombolysis can serve as an independent predictor of 3-months poor outcome in AIS patients. This simple and readily available data may help clinicians to improve the prognostic estimation of patients and may provide guidance in selecting patients for personalized and intensified care post-thrombolysis.
Central nervous system (CNS) involvement is one of the numerous extraglandular manifestations of primary Sjögren’s syndrome (pSS). Moreover, neurological complaints precede the sicca symptoms in 25–60% of the cases. We review the magnetic resonance imaging (MRI) lesions typical for pSS, involving the conventional examination, volumetric and morphometric studies, diffusion tensor imaging (DTI) and resting-state fMRI. The most common radiological lesions in pSS are white matter hyperintensities (WMH), scattered alterations hyperlucent on T2 and FLAIR sequences, typically located periventricularly and subcortically. Cortical atrophy and ventricular dilatation can also occur in pSS. Whilst these conditions are thought to be more common in pSS than healthy controls, DTI and resting-state fMRI alterations demonstrate evident microstructural changes in pSS. As pSS is often accompanied by cognitive symptoms, these MRI alterations are expectedly related to them. This relationship is not clearly delineated in conventional MRI studies, but DTI and resting-state fMRI examinations show more convincing correlations. In conclusion, the CNS manifestations of pSS do not follow a certain pattern. As the link between the MRI lesions and clinical manifestations is not well established, more studies involving larger populations should be performed to elucidate the correlations.
Immunoglobulin G4-related disease (IgG4-rd) is characterized by lymphoplasmacytic infiltration and tissue fibrosis. Orbital manifestations of IgG4-rd may include unilateral or bilateral proptosis, cicatricial extraocular muscle myopathy, orbital inflammation and pain which may mimic ophthalmic Graves’ disease. A 25-year-old woman has been referred to the endocrinology clinic, 4 months after delivery, with suspected Graves’ orbitopathy. She has had bronchial asthma and recurrent skin rashes of unknown aetiology for the last 10 years and was treated for dacryoadenitis with steroid containing eye drops 5 years ago. During pregnancy she developed eyelid swelling. After delivery, eyelid redness and retrobulbar pain evolved. Proptosis was demonstrated by Hertel’s exophthalmometry. Orbital magnetic resonance imaging showed enlarged lateral and superior rectus muscles in both orbits. Thyroid function tests were in the normal range and no thyroid stimulating hormone (TSH) receptor autoantibodies were present. The eye muscle involvement pattern raised suspicion, and the high IgG4 level with positive histology of the lacrimal gland confirmed the diagnosis of immunoglobulin G4-related orbitopathy. Rapid improvement was observed following oral methylprednisolone. IgG4-related orbitopathy may mimic Graves’ orbitopathy. Euthyroid patients with no TSH receptor autoantibodies should be evaluated for immunoglobulin G4-related orbitopathy. Once IgG4-related orbitopathy is proven, other manifestations of IgG4-related disease have to be searched for; lifelong follow-up is warranted.
The objectives of our study were to (a) evaluate the feasibility of using 3D printed phantoms in magnetic resonance imaging (MR) in assessing the robustness and repeatability of radiomic parameters and (b) to compare the results obtained from the 3D printed phantoms to metrics obtained in biological phantoms. To this end, three different 3D phantoms were printed: a Hilbert cube (5 × 5 × 5 cm3) and two cubic quick response (QR) code phantoms (a large phantom (large QR) (5 × 5 × 4 cm3) and a small phantom (small QR) (4 × 4 × 3 cm3)). All 3D printed and biological phantoms (kiwis, tomatoes, and onions) were scanned thrice on clinical 1.5 T and 3 T MR with 1 mm and 2 mm isotropic resolution. Subsequent analyses included analyses of several radiomics indices (RI), their repeatability and reliability were calculated using the coefficient of variation (CV), the relative percentage difference (RPD), and the interclass coefficient (ICC) parameters. Additionally, the readability of QR codes obtained from the MR images was examined with several mobile phones and algorithms. The best repeatability (CV ≤ 10%) is reported for the acquisition protocols with the highest spatial resolution. In general, the repeatability and reliability of RI were better in data obtained at 1.5 T (CV = 1.9) than at 3 T (CV = 2.11). Furthermore, we report good agreements between results obtained for the 3D phantoms and biological phantoms. Finally, analyses of the read-out rate of the QR code revealed better texture analyses for images with a spatial resolution of 1 mm than 2 mm. In conclusion, 3D printing techniques offer a unique solution to create textures for analyzing the reliability of radiomic data from MR scans.
Background/Objectives: Big data analysis has revolutionized medical research, making it possible to analyze vast amounts of data and gain valuable insights that were previously impossible to obtain. Our knowledge of the characteristics of vitamin D sufficiency is primarily based on data from a limited number of observations, generally spanning a few years at most. Methods: Here at the Medical Faculty of the University of Debrecen, the big data approach has allowed us to analyze trends in vitamin D status using nearly 60,000 25-hydroxyvitamin D (25(OH)D) concentration results from 2000 onwards. Results: Apart from analyzing the well-known phenomenon of seasonality in 25(OH)D concentration, we observed a trend in test requests, which increased from a few hundred in 2000 to almost 10,000 in 2020. Of particular interest is the change in the gender gap in test requests. In previous years, test requests were primarily from women, but by the end of the analysis period, a significant number of requests were from men as well. Since the data set includes all age groups, we analyzed 25(OH)D concentration for incremental age sets of five years, from a few months to 100 years old. The prevalence of vitamin D insufficiency (<75 nmol/L) was clearly demarcated among various years of observation, age groups, sexes, and seasons. Our data was particularly valuable for analyzing the effect of the methodology used for 25(OH)D determination. Three different methodologies were used during the study period, and clear, statistically significant bias was observed. Conclusions: Our results clearly demonstrate the effect of the methodology used to determine 25(OH)D concentrations on vitamin D status, explicitly highlighting the urgent need to standardize the various platforms used to measure this important analyte and its consequences for public health.
Background: We assessed the frequency and causes of discrepancies in CT dose indices such as dose-length product (DLP), size-specific dose estimate (SSDE), and effective dose (ED), as calculated by CT dose-monitoring systems. Our secondary aim was to demonstrate the estimation of size-specific ED (SED) from the patients’ dose records. Methods: The retrospective study included dosimetric data of 79,383 consecutive CT exams performed on two CT scanners. The following dose values were recorded from both the locally developed dose-monitoring system (DMS) and a commercial dose-monitoring program (DWTM): DLP, SSDE, and ED. Only the DMS provided bodyweight-corrected effective dose (SEDDMS) and the SED based on previous published data. Results: Without body-region-specific analysis, there were no tendentious differences between the DLP, ED, or SSDE values obtained from DWTM and DMS. However, the body region-based correlation revealed substantial differences between EDDMS and EDDW, primarily related to inadequate identification of the body. SSDE showed strong correlation to each anatomical category and CT device, except for the head region, where inadequate consideration of CT inclination was the reason for the biased SSDEDW value. Furthermore, by analyzing the SEDDMS, SSDE, and SED correlations, we concluded that SEDDMS is a promising figure for estimating the SED value. Conclusions: SED provides suitable supplementary size-specific dose data to SDDE and may be a preferable choice for estimating cumulative doses in routine radiological practice.