Previously, we developed an "activity painting" tool for PET image simulation; however, it could simulate heterogeneous patterns only in the air. We aimed to improve this phantom technique to simulate arbitrary lesions in a radioactive background to perform relevant multi-center radiomic analysis. We conducted measurements moving a 22Na point source in a 20-liter background volume filled with 5 kBq/mL activity with an adequately controlled robotic system to prevent the surge of the water. Three different lesion patterns were "activity-painted" in five PET/CT cameras, resulting in 8 different reconstructions. We calculated 46 radiomic indeces (RI) for each lesion and imaging setting, applying absolute and relative discretization. Reproducibility and reliability were determined by the inter-setting coefficient of variation (CV) and the intraclass correlation coefficient (ICC). Hypothesis tests were used to compare RI between lesions. By simulating precisely the same lesions, we confirmed that the reconstructed voxel size and the spatial resolution of different PET cameras were critical for higher order RI. Considering conventional RIs, the SUVpeak and SUVmean proved the most reliable (CV<10%). CVs above 25% are more common for higher order RIs, but we also found that low CVs do not necessarily imply robust parameters but often rather insensitive RIs. Based on the hypothesis test, most RIs could clearly distinguish between the various lesions using absolute resampling. ICC analysis also revealed that most RIs were more reproducible with absolute discretization. The activity painting method in a real radioactive environment proved suitable for precisely detecting the radiomic differences derived from the different camera settings and texture characteristics. We also found that inter-setting CV is not an appropriate metric for analyzing RI parameters’ reliability and robustness. Although multicentric cohorts are increasingly common in radiomics analysis, realistic texture phantoms can provide indispensable information on the sensitivity of an RI and how an individual RI parameter measures the texture.
Background: Since metabolic diseases and atherosclerotic vascular events are firmly associated, herein we investigate changes in central microcirculation and atherosclerosis-related body fat distribution in patients with type 2 diabetes mellitus and obesity. Methods: Resting brain perfusion single-photon emission computed tomography (SPECT) imaging with Technetium-99m hexamethylpropylene amine oxime ([99mTc]Tc-HMPAO SPECT) was performed, and the breath-holding index (BHI) and carotid intima-media thickness (cIMT) were measured to characterise central microcirculation. Besides CT-based abdominal fat tissue segmentation, C-peptide level, glycaemic and anthropometric parameters were registered to search for correlations with cerebral blood flow and vasoreactivity. Results: Although no significant difference was found between the resting cerebral perfusion of the two patient cohorts, a greater blood flow increase was experienced in the obese after the breath-holding test than in the diabetics (p < 0.05). A significant positive correlation was encountered between resting and provocation-triggered brain perfusion and C-peptide levels (p < 0.005). BMI and cIMT were negatively correlated (rho = −0.27 and −0.23 for maximum and mean cIMT, respectively), while BMI and BHI showed a positive association (rho = 0.31 and rho = 0.29 for maximum and mean BHI, respectively), which could be explained by BMI-dependent changes in fat tissue distribution. cIMT demonstrated a disproportional relationship with increasing age, and higher cIMT values were observed for the men. Conclusions: Overall, C-peptide levels and circulatory parameters seem to be strong applicants to predict brain microvascular alterations and related cognitive decline in such patient populations.
Background: We assessed the frequency and causes of discrepancies in CT dose indices such as dose-length product (DLP), size-specific dose estimate (SSDE), and effective dose (ED), as calculated by CT dose-monitoring systems. Our secondary aim was to demonstrate the estimation of size-specific ED (SED) from the patients’ dose records. Methods: The retrospective study included dosimetric data of 79,383 consecutive CT exams performed on two CT scanners. The following dose values were recorded from both the locally developed dose-monitoring system (DMS) and a commercial dose-monitoring program (DWTM): DLP, SSDE, and ED. Only the DMS provided bodyweight-corrected effective dose (SEDDMS) and the SED based on previous published data. Results: Without body-region-specific analysis, there were no tendentious differences between the DLP, ED, or SSDE values obtained from DWTM and DMS. However, the body region-based correlation revealed substantial differences between EDDMS and EDDW, primarily related to inadequate identification of the body. SSDE showed strong correlation to each anatomical category and CT device, except for the head region, where inadequate consideration of CT inclination was the reason for the biased SSDEDW value. Furthermore, by analyzing the SEDDMS, SSDE, and SED correlations, we concluded that SEDDMS is a promising figure for estimating the SED value. Conclusions: SED provides suitable supplementary size-specific dose data to SDDE and may be a preferable choice for estimating cumulative doses in routine radiological practice.